SCA1001FSS001 General Electric Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Robert from COLORADO SPGS, CO
- Parts Used:
- WB27X10037, WB24X25397, WB24X10047
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James C from ARLINGTON, TX
- Parts Used:
- WB20X10048
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent opening to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from WANTAGH, NY
- Parts Used:
- WB10X10021
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The door latch broke.
It was really easy. I am not a handy person but I followed a video and got it done quite quickly. It saved me a lot of money. The local appliance repair service charges a minimum of $75 just for the visit plus parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from TAMPA, FL
- Parts Used:
- WB10X10021
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Latch for door broken
Unplug power source.
Took off plastic panel partially on inside of door with door on its hinge.
Removed latch and spring.
Reinstalled new latch new spring (new part)
Reattached plastic panel to door.
Plug in power.
Took off plastic panel partially on inside of door with door on its hinge.
Removed latch and spring.
Reinstalled new latch new spring (new part)
Reattached plastic panel to door.
Plug in power.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stacie from Granbury, TX
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave would not heat. Convection still worked.
I verified I had 120 volts going into transformer when the microwave was supposed to be running. The capacitor and HV diode both tested good. Be sure to discharge the capacitor before working in this area. This isolated trouble to either the transformer or magnetron. The windings of the transformer measured good. So ordered a magnetron. It was very easy to swap. There were 4 screws and one connector. This fixed our microwave.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from ANTIOCH, IL
- Parts Used:
- WB06X10311
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
burned wave guide cover
remove with phillips screwdriver. insert 3 corners in to slots and insert and tighten screw.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Loretta from PRT JEFFERSON, NY
- Parts Used:
- WB10X10021
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
door latch broken
removed broken latch connected to existing spring done in less than two minutes works better than new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from BLUFFTON, SC
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The unit would run when the door was open!
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- william from LA VERNE, CA
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set, Wrench (Adjustable)
Unit would not heat
Used a Motor cycle Jack to remove both unites combined. Removed side panels exposing internal working parts. Removed nonworking Magnetron and replaced it with new Magnetron. The process was completed in about 1 hour.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judith A from LAKEWOOD, CO
- Parts Used:
- WB36X10163
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light bulb went out
Opened the light cover. Removed the old light bulb using a light tug on the old bulb, lined up the new bulb and pushed gently into the socket.
Turned the power back on and the microwave is good to go.
Turned the power back on and the microwave is good to go.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from FULSHEAR, TX
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gilbert from TOMS RIVER, NJ
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rex from ROSEVILLE, CA
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Microwave wouldn’t heat
I want to preface this review by stating that I do some DIY from YouTube, but have no experience in electronic repair. The microwave is over the stove with the extendavent. First I unplugged the microwave, removed the vent and started to unscrew the microwave from the mount. I used a power drill to speed things up. I was able to remove the microwave on my own. I unscrewed the lid on the microwave and took the lid off and there is the magnetron. I opened up needle nose pliers to have each end touch the terminals of the capacitor (holds the power, Dangerous). I made sure to keep my hands on the rubber handles and avoid touching the metal part of the pliers. I used the pliers to remove the plug of the capacitor to the magnetron as well. The magnetron has 4 screws (2 top, 2 bottom). There is a magnet that can hold the screws to keep from falling but I’d still recommend a screwdriver with a magnet on the end. The magnetron has another set of wires connected by a metal bracket like a holder, not really connecting any wiring to the magnetron itself. I had to unscrew 1 screw to removed that. Adding everything back on was easy, same steps back. I plugged in the microwave and tested a cup of water before I mounted it back above the stove. Voila! I did need my wife’s help to hold the microwave on the hinge while screwing into the mount. It doesn’t take a lot of muscle for the help. $85 for the part and ~40 mins to fix a $400 microwave!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kip from POWELL, OH
- Parts Used:
- WB27X10928
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pearlie from Beulaville, NC
- Parts Used:
- WB27X10928
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followed them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Was this instruction helpful to you?
Thank you for voting!