Customer:
William from Socorro, NM
Parts Used:
WB27X10928
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Quit working
Just like the directions said. Very simple.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MANUEL from ESCONDIDO, CA
Parts Used:
WB27X10597
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
diode burnt
it was a simple screw in on both ends. no soldering
Was this instruction helpful to you?
Thank you for voting!
Customer:
Claudia from Monroe, WA
Parts Used:
WB06T10012
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Roller Guide
Lifted up the glass plate. Put in the new roller guide. Set the glass plate back in place. Repair done in about 30 seconds! Thanks for prompt service in sending the new part. My only regret is that the part was expensive, and I have already replaced it once before. The new part is still plastic so will probably need to be replaced again.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kathleen from Munt Laurel, NJ
Parts Used:
WB20T10024
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Oven Probe broke
Ordered new probe
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Albuquerque, NM
Parts Used:
WB02T10017
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Convection fan came loose from shaft
Convection fan came loose from the shaft with a lout rattle and grinding as the fan spun down. Had to remove four metal screws to remove the fan cover. Initially tried to just put the nut back on to hold the fan. However, I could not get the nut to start, so I assumed that threads were stripped on the nut or the shaft. Ordered the replacement nut, hoping that it was the nut that was the problem. However, I had the same problem with the new nut. I could see no damage on the shaft. It finally occurred to me that the nut and shaft had left-hand threads (counter-clockwise to tighten). At that point, it was extremely easy to put the nut back on and tighten it. I did not try using the old nut, since I had already received the new one, but I'm certain that if I had come to that realization earlier, I could have saved time and money. So, if you have the same problem, try putting the nut on "backwards."
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Hot Springs Village, AR
Parts Used:
WB27X10073
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
Microwave died-no display-15amp fuse blows
I shut off power to the microwave, discharged the Hi-voltage capaciator and disconnected the wires to it, then removed the screw and bracket that held the capaciator in place. After removing and replacing the capaciator, reattaching wires and mounting bracket, and replacing the 15amp fuse, the microwave woked fine.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Abid from Cross River, NY
Parts Used:
WB03T10211
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The push button on the microwave would not align
Opened the control panel removed the push button and installed the new one. Please make sure to turn the power off from the circuit breaker before opening the panel.
Was this instruction helpful to you?
Thank you for voting!