John from Norman, OK
Parts Used:
W10822259
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set, Wrench set
Fan motor making noise then failed. Ice maker stopped making ice
Once I determined easier access to the fan motor, I removed the three fan motor screws that held the motor on place. After removing the motor I remove the fan blade assembly held by one nut and reattached to the new motor. I then reattached the new motor with 3 new screws which were provide and reattached the power cord with the cord clip and began reassembling the icemaker housing, then moved the unit back in place which was installed under counter. I could do this repair in less than 45 minutes now that I have done it once. I saved several hundred $ from the original estimate and the parts were delivered in 2 days after I ordered online. This is definitely a DIY project!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Drew from Birmingham, AL
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Socket set
After 5 years the pump gave out, but much cheaper to replace than buy new ice maker
1 Turn off ice maker and drain water reseviour (cap at bottom of reseviour) 2. Remove internal ice storage door to give you more working room 3. Remove water resevious (two screws on either side of reseviour) and disconnect plastic tubing in reseviour 4. Remove cover shield at top that covers the ice cutting mechanism (two screws at bottom of cover 3. Remove cover shield covering pump (1 screw) 4. Remove small plastic tubing on side of pump (this part is a little tricky) 5. Remove the three screws holding pump to unit (one at back and two on the side (one in front of pump and one in back of pump) 6. Disconnect power supply to pump 7. Remove pump and replace
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Friendswood, TX
Parts Used:
WP2217220
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Wrench (Adjustable)
Hard water deposits salted pump motor
Disconnect water line and power cord, Remove scoop holder, water reservoir and shield around pump to access pump, removed hose connected to pump then removed pump (3- 1/4" hex screws) and disconnected wire harness and 1/4" plastic water line attached to pump bracket, reverse process
Was this instruction helpful to you?
Thank you for voting!
Customer:
Juergen from Belle Chasse, LA
Parts Used:
WP2313637
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
removing broken cutter grid
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the instructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Anchorage, KY
Parts Used:
4387020
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
cutting grid wire broke
Bought new wire, strung it end to end and fastened it at each end.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raylene from Taylorsville, UT
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
had to replace Scotsman ice maker pump
didn't go well at first. Got it all hooked up relatively easily but it didn't work. Called customer service who suggested hooking pump up to other power source to be sure it worked. It still didn't work. After closer inspection a connection wasn't hooked up on pump. After connecting got it back in about 30 min. Working like a charm now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Safety Harbor, FL
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Our ice machine froze up when we were away and burnt out the motor.
We guessed what the problem was and we were extremely fortunate that we guessed correctly. The part was not technically difficult to install just a little awkward to get to. My husband had no trouble although he did take the machine out of it's space and lay it flat on the floor. One benefit of this process was being able to clean some of the areas that are almost impossible to get to when the motor is in place. It was well worth the extra shipping charge to get it before the weekend.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Cypress, TX
Parts Used:
WP2217220
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Circulation Pump not working
Follow the instructions already submitted by others. As mentioned be sure to place towel inside to cover the drain. My 3-wire electrical connector also had some corrosion build-up so I had to remove the bracket holding the connecter cut the 3-wires and install a new connector. Not a big deal, you are just working in a small enclosed area. Pulling the entire unit out and either elevating or tilting back helps with the access. Be sure to check drain connection in the back of the unit when putting back in place. Having a headband light helps for entire repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Mission Viejo, CA
Parts Used:
W10822259
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Fan motor making awful noise, not turning very fast
Fan was barely rotating. So unplugged, removed back cover, removed fan and motor from frame work. Removed fan blade from motor shaft. Spun motor shaft which seemed fine. Pryed off back cover of motor to find a large but dry felt washer and a helical capillery slot formed into the motor shaft for carring oil from felt washer to the bearings. Added 30 wt motor oil and some 3in1 oil to felt and reassembled motor, fan and frame work. Plugged in power chord after getting rid of dust and dog hear on coils and is working like new.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Rensselaer, NY
Parts Used:
W10822259
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Socket set
condenser fan motor quit
Technically, the repair did not require specialized knowledge. However, replacement of the motor required some effort. Because the motor is located at the bottom of the unit in an area with copper tubing & wiring hindering access it was physically difficult to remove and then replace the motor. A problem arose because the shaft on the replacement motor was larger than the original motor's. Thus the fan would not fit on the new motor. Luckily, I found a fan locally that fit the motor. It would be very helpful if a fan was included in the motor kit. The ref. is now running smoothly
Was this instruction helpful to you?
Thank you for voting!