Customer:
David from BLACKLICK, OH
Parts Used:
W10124096
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
loud griding noise
stopped the fan and noise stopped ordered fan motor and fan with interface cable. Using 1/4 inch nut driver to remove screws from motor bracket installed new motor and runs like new.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from BULLHEAD CITY, AZ
Parts Used:
W10124096
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Noisy condenser fan
I suggest following video supplied with order confirmation perfect fit
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Guy from SURFSIDE BCH, SC
Parts Used:
W11566405
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Disherwasher would not start
Found fault with recirculating pump. Found hot spot on pump circuit board . Replaced pump
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from NORMAN, OK
Parts Used:
WP2313637
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Broken ice cutter grid
Unplugged the unit. Removed 2 screws to remove front cover to access the cutter grid.removed 2 screws to the cutter grid, unsnapped power connector and removed broken grid. Slid new grid in place, reconnected power connector, replaced screws, plugged in ice maker and slid back in place. Very easy!!!
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ken from Huntsville, AL
Parts Used:
W11566407, WPW10548509, W11566405
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
One of the circulation pumps was going bad and making a loud noise.
I replaced the two pumps, since both were the same design...figuring if one went bad then the other would soon go bad...and then I also replace the water level sensor. All had quick connect plugs. The time is just taking apart the various pieces, cleaning, installing the new pumps and sensor, then reassembling.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Atlee from Jupiter, FL
Parts Used:
WP2149705
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
broken light switch
Figured out You have to pop off the cocer than remove the 1/4 hex head screws only not the philips ones
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Howard from Boynton Beach, FL
Parts Used:
350930
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Both outside door handles turned very beige
Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
23 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lynn from Marshall, IL
Parts Used:
WP99003172
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Water was running out of ice maker tray.
unscrewed the old one! installed the new one! That simple. And I'm female, how easy was that!
2 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from GLEN CARBON, IL
Parts Used:
72032, 4392899
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
black scratchers from wheel chair
shook bottle and painted waited a day and repeated
3 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cynthia from Wilmington, DE
Parts Used:
W10124096
Difficulty Level:
Very Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
No ice, the cabinet was warm, but most annoying it broke every 6 mos since I got it
I replaced the thermometer first and it started working again. I was convinced that the reason that it continued to break every 6mos was because no one had ever replaced the fan. The difficult part was getting to it. After trying to get in from the front and from the back I finally figured out that I had to take the bottom off and tilt it on its side. I was then able to get out the pin in the condenser and move it to the side. I could then reach the screws that held in the fan. I then decided to put the fan on the motor and when I was tapping it on with a hammer the back cracked. I attempted to fix it by taking apart the old motor and salvaging the parts but that didn't work. I had to buy another $85 part and take the whole thing apart again. It was easier the second time because I knew which screws and pins I had to remove and how to get to them. I very, very carefully tapped the fan onto the motor and now it is working fine. I will let you know if it is still working at Easter. If it is I will have done a better job than the 7or 8 repairmen who have fixed it in the past
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mitchell from Danville, KY
Parts Used:
WP2324334
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Water bucket had cracked and leak
Remove pump and hoses from bad bucket, removed bucket and install new bucket . To remove pump, remove screw holding pump and turn pump 1/4 turn. Be careful Putting new bucket back, can break hose if not careful. Good luck
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gene from Battle creek, MI
Parts Used:
W11566405
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Recirculating pump stopped working
Remove ice tray and guard over moter. Un plug the 3 plugs and pull the entire motor assembly out. Use a screw driver to gently pry motor out. Snap in the new motor(the wiring was on the wrong side and the power cord coloring backwards on the replacement motor, but I snapped it in with the colors criss crossed and it worked). Re plug in the 3 plugs. Re mount mounting assembly, tray and then guard. Had a little trouble getting the tray back in. There is a little flap in the back that goes inside the tray. Other than that, a pretty easy fix.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Juergen from Belle Chasse, LA
Parts Used:
WP2313637
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
removing broken cutter grid
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the instructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Fairport, NY
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Socket set
Wobble in fan made a ticking noise.
Pulled out the Fridge. Removed the plug. Removed the back panel screws with nut driver. Vacuumed the coils & fan area. Disconnected the fan cable. Used a socket and thumb ratchet to remove the 3 mounting screws from its sheet metal bracket. Slid the old fan assembly out. Assembled the new Fan blade onto the new motor shaft and attached the adapter cable to the fan connector. Slid the assembly into place and reattached with 3 screws using socket and thumb ratchet. Connected adapter cable to fridge harness and plugged in the power cord to test the fan. With it working Quietly and knowing the the problem was solved, the back panel was reattached.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Albuquerque, NM
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
condenser fan motor worn out and making noise.
Instructions were really clear and easy to follow. Hardest part of the job was moving the refrigerator away from wall after it was filled with holiday groceries.