KUIC15NRSS0 KitchenAid Ice Maker - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- kevin from Antelope, CA
- Parts Used:
- W10124096
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
refrigerator not cold. and keeps striping the circuit breaker and shutting off other appliances using the same circuit.
what I discovered is the condenser fan is still operating but not strong another word insufficient cooling for the condenser. therefore, it's getting too hot and shutting off and stripped the circuit breaker. After installing the new condenser fan, it gets back in business. it's quite simple. Just unplug the unit off, uncover the bottom back cover and there you see compressor, condenser fan and other good stuff. there you unscrew the nut in front of the condenser fan and remove the fan, then it expose the two screws that holding the fan motor, remove these screws and take out the motor. and just install the new fan motor kit in and there you have it. plug it back to the wall and there it goes
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- manuel from wilmington, DE
- Parts Used:
- W10124096
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Very noisy when condensor fan came on
I've tried ordering the part from Sears and they told me it will take about 7 days for the part to arrive, some other place said it will overnite for extra money. So I've ordered the part from Part Select at a good price and prompt delivery. once the part arrive installing the part so so easy cause it had easy to follow instructions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Cave Creek, AZ
- Parts Used:
- W10124096
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Fan became noisy and started wobbling.
UPS delivered the part at 11:05 AM and I had it installed in less than 30 minutes. No issues, easy removal and re-installation although the compartment was very tight for my hand and a 1/4" drive socket wrench. One installation suggestion however, pre-thread the 3 mounting screw holes on the motor housing first by screwing one of the screws provided into each of the three mounting holes on the motor housing prior to attempting to install the new motor. This way you'll find it much easier to get start the screws given the very limited work-space behind the fan compartment.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kerry from Franklin, TN
- Parts Used:
- W10124096
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Condenser Fan was making noise
Having read a few of the user reports like this one gave me the confidence to do this repair. The space was really tight, but one of the write ups suggested removing the frame and then replacing the motor on the frame. That was an excellent suggestion. The only difficulty I had was when I used the motor screws from the old motor to install the new motor. They were slightly longer and didn't tighten down all the way. So the first "test" resulted in still having a noisy fan motor because it was shaking around a bit. But, taking it back out and using the screws that came with the new motor did the trick. The refrigerator is now whisper quiet all the time. I also appreciated the conversion wiring harness in the kit that was simply plug and play for this new motor to my old refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Juergen from Belle Chasse, LA
- Parts Used:
- WP2313637
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
removing broken cutter grid
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the instructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Friendswood, TX
- Parts Used:
- WP2217220
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Hard water deposits salted pump motor
Disconnect water line and power cord, Remove scoop holder, water reservoir and shield around pump to access pump, removed hose connected to pump then removed pump (3- 1/4" hex screws) and disconnected wire harness and 1/4" plastic water line attached to pump bracket, reverse process
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raylene from Taylorsville, UT
- Parts Used:
- WP2217220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
had to replace Scotsman ice maker pump
didn't go well at first. Got it all hooked up relatively easily but it didn't work. Called customer service who suggested hooking pump up to other power source to be sure it worked. It still didn't work. After closer inspection a connection wasn't hooked up on pump. After connecting got it back in about 30 min. Working like a charm now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Anchorage, KY
- Parts Used:
- 4387020
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set
cutting grid wire broke
Bought new wire, strung it end to end and fastened it at each end.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Drew from Birmingham, AL
- Parts Used:
- WP2217220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set
After 5 years the pump gave out, but much cheaper to replace than buy new ice maker
1 Turn off ice maker and drain water reseviour (cap at bottom of reseviour) 2. Remove internal ice storage door to give you more working room 3. Remove water resevious (two screws on either side of reseviour) and disconnect plastic tubing in reseviour 4. Remove cover shield at top that covers the ice cutting mechanism (two screws at bottom of cover 3. Remove cover shield covering pump (1 screw) 4. Remove small plastic tubing on side of pump (this part is a little tricky) 5. Remove the three screws holding pump to unit (one at back and two on the side (one in front of pump and one in back of pump) 6. Disconnect power supply to pump 7. Remove pump and replace
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Groton, CT
- Parts Used:
- WP2217220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Water circulation pump not working
I determined the pump was not working by running the ice maker. After it started a cycle, I could fell the underside of the cold plate to insure it was indeed cold, but no water was flowing.
First, be sure the water pump electrical plug is in., it releases by pressing together the tabs at the ends, not sides.
To replace the pump, turn off the water supply and cover the drain hole at the bottom of the ice bin so you don’t drop parts down it. The screw-plug at the bottom of the water tank or a quarter will do.
Remove the water tank below the pump by taking out the thumbscrews at both ends. You can then see the hose at the bottom of the pump. If it is off, that may be the problem.
To remove the pump, pull the fill hose to the left out of the slot and bend it behind the pump to get it out of the way. Unplug the electrical connector and the pump hose. There are three ¼” hex head screws, teo on the side wall, one in back. The middle one is the hardest to access. I used both a nut driver and a socket wrench with a 4” extension.
When installing the new pump, be sure to plug in the electrical connector, the discharge hose at the bottom and position the fill tube as you found it. Forget any of these and nothing works. Re-install the water tank, replace the drain plug and turn on the water supply, in that order.
First, be sure the water pump electrical plug is in., it releases by pressing together the tabs at the ends, not sides.
To replace the pump, turn off the water supply and cover the drain hole at the bottom of the ice bin so you don’t drop parts down it. The screw-plug at the bottom of the water tank or a quarter will do.
Remove the water tank below the pump by taking out the thumbscrews at both ends. You can then see the hose at the bottom of the pump. If it is off, that may be the problem.
To remove the pump, pull the fill hose to the left out of the slot and bend it behind the pump to get it out of the way. Unplug the electrical connector and the pump hose. There are three ¼” hex head screws, teo on the side wall, one in back. The middle one is the hardest to access. I used both a nut driver and a socket wrench with a 4” extension.
When installing the new pump, be sure to plug in the electrical connector, the discharge hose at the bottom and position the fill tube as you found it. Forget any of these and nothing works. Re-install the water tank, replace the drain plug and turn on the water supply, in that order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Safety Harbor, FL
- Parts Used:
- WP2217220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Our ice machine froze up when we were away and burnt out the motor.
We guessed what the problem was and we were extremely fortunate that we guessed correctly. The part was not technically difficult to install just a little awkward to get to. My husband had no trouble although he did take the machine out of it's space and lay it flat on the floor. One benefit of this process was being able to clean some of the areas that are almost impossible to get to when the motor is in place. It was well worth the extra shipping charge to get it before the weekend.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Cypress, TX
- Parts Used:
- WP2217220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Circulation Pump not working
Follow the instructions already submitted by others. As mentioned be sure to place towel inside to cover the drain. My 3-wire electrical connector also had some corrosion build-up so I had to remove the bracket holding the connecter cut the 3-wires and install a new connector. Not a big deal, you are just working in a small enclosed area. Pulling the entire unit out and either elevating or tilting back helps with the access. Be sure to check drain connection in the back of the unit when putting back in place. Having a headband light helps for entire repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cynthia from Wilmington, DE
- Parts Used:
- W10124096
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
No ice, the cabinet was warm, but most annoying it broke every 6 mos since I got it
I replaced the thermometer first and it started working again. I was convinced that the reason that it continued to break every 6mos was because no one had ever replaced the fan. The difficult part was getting to it. After trying to get in from the front and from the back I finally figured out that I had to take the bottom off and tilt it on its side. I was then able to get out the pin in the condenser and move it to the side. I could then reach the screws that held in the fan. I then decided to put the fan on the motor and when I was tapping it on with a hammer the back cracked. I attempted to fix it by taking apart the old motor and salvaging the parts but that didn't work. I had to buy another $85 part and take the whole thing apart again. It was easier the second time because I knew which screws and pins I had to remove and how to get to them. I very, very carefully tapped the fan onto the motor and now it is working fine. I will let you know if it is still working at Easter. If it is I will have done a better job than the 7or 8 repairmen who have fixed it in the past
Was this instruction helpful to you?
Thank you for voting!