Models > RV15EFREW02 > Instructions

RV15EFREW02 Roper Freezer - Instructions

Jump to:

All Instructions for the RV15EFREW02
1 - 13 of 13
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Michelle from Richardson, TX
Parts Used:
72017
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Scratches in Surface
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
64 of 125 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LESLIE from TAPPAHANNOCK, VA
Parts Used:
WP4357099
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
gasket had harden. frost was building up quickly
the gasket peels back to reveal the approx 20 screwsholding gasket and door shelves. removed these. removed old gasket from door panel. new gasket needs to be stretched to get on door panel. align screw holes in door panel with screw holes in gasket. attached back to freezer door. this gasket did not seal securely when closing door. this gasket was installed on a cold day in a garage and may become more flexible as it warms up.
25 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
SAL from UPLAND, CA
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Refrigerator stop working
First I removed the relay and over load and exam. Saw that the relay was burnt. Before I order the part I check to see if the compressor was still working by jumping the common start and run terminals.It did. I also checked the start capacitor with a capacitor tester it was good. I than order the part which came the very next day.Installed the part
22 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Howard from Boynton Beach, FL
Parts Used:
350930
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Both outside door handles turned very beige
Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
22 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jonathan from OLIVE BRANCH, MS
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Removed the old parts then connected the new parts.
The compressor immediately started when I plugged the refrigerator back in. Around 24 hours later the freezer compartment was at 0 degrees, and the refrigerator was at 35 degrees.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
stephen from montgomery, NY
Parts Used:
W11117769
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Wrench (Adjustable)
No leveling legs
Ordered the leveling bolts, very fast shipping, parts correct as shown. Purchased a condo by the shore, frige had no levelers, they went in smoothly & was done in no time.
Steve
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Oliver from Madison, AL
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Cimpressor would not start
Checked compressor with amp meter, and found it was not running, found Overload Switch bad.
When removing old switch watch carefully which lug you move wires from, so you will know which
lug to put the new switch on.

BE SURE YOU KNOW SOMETHING ABOUT
ELECTRICITY!!
4 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Frankfort, KY
Parts Used:
W11117769
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Renters removed leveling legs from refrigerator. I don't know why!
I tilted the unit back enough to scew the new legs into the threaded holes.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bobby from New Bern, NC
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
After Hurricane Irene refrigeration compressore did not start
Followed the directions. Installation was quick. Took loner to put the covers back on and push the applicance back in position than the repair.
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Boxborough, MA
Parts Used:
4387535
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
change relay
unplugged relay and plugged in
3 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Conroe, TX
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Starting relay went out
Forty years ago I serviced air conditioners and all kinds of refrigeration. At that time starting relays were electro mechanical, I hadn’t looked under a refrigerator in a lot of years and was surprised to find out that the new relays were solid state. The defective one had a bunch of broken pieces floating around in the case. I jury rigged a starting cord and confirmed that the compressor would start and looked at running current for thirty or so seconds. I ordered a new relay kit and it worked just right. I’m seventy five years old and it takes me longer to get up off the floor than it took to replace the parts. Your delivery was first rate the parts got here before I finished doing the paint touch-up on the door under the ice maker/water dispenser. Fed ex was easily three to five days faster than the brown truck.
4 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roy L from Layton, UT
Parts Used:
4-80576-202
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken left arm to hold rack in
Just put the two screw back in that i had removed.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Jay, ME
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
compressor clicks on for about 5 seconds and then shuts off, evaporator fan is running but no cooling in the fridge.
Disconnect power. Remove back panel on the refrigerator. Relay and overload is a modular unit attached to the compressor. Disconnect module from compressor, install new unit. While you're in there clean the condenser coils with a vacuum and clean the fan and condensate pan. Reassemble, and you're chillin. Total time approx. 15 min.
Was this instruction helpful to you?
Thank you for voting!