Models > 25344733105 > Instructions

25344733105 Kenmore Freezer - Instructions

Jump to:

All Instructions for the 25344733105
46 - 60 of 142
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Chris from Lockport, NY
Parts Used:
241639502
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.

I removed the broken fan from the condenser. This was very sipmle.

When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
12 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from BROOKLYN, NY
Parts Used:
IM116000
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Old Icemaker kept jamming
Remove Ice container - loosen 2 Phillips screws -unplug electrical plug by squeezing sides- lift old icemaker up off the screws and remove - Plug in the new ice maker - place new icemaker so water inlet goes into new ice maker, slide up over existing screws and slide down - tighten screws and replace ice container
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
warren from Farmdale, OH
Parts Used:
297013500
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken drawer slide
removed old broken part, 3 screws, then installed new part.....done
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Xavier from Philadelphia, PA
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The freezer was too warm. The fan was running: the diagnosis tool did not work!
I used the tool at Partselect that in theory allows diagnostic of the problem to be repaired. The result was that more tan 90% of the time with the introduced symptoms it had to be the thermostat. I order the part, got it quickly and installed. It did not fix the problem. So, be careful with the diagnostic tool, because it is just based on what most people buy when they have a particular problem. Videos for installation are great. If diagnosis was better, this would be fantastic. In my case there might be a different problem.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marc from Chesterfield, MA
Parts Used:
297216600
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Freezer fine, fridge too hot!
Removed the back panel in freezer compartment with the nut-driver. Then I cut off old thermostat connections, and spliced in new thermostat connections (repairman had already replaced defrost timer, and said not to trust connectors included on wires-they failed often). Then I snapped thermostat itself onto cooler coil. So far so good, fridge is running at 35-40 degrees a week later. Thanks Parts-Select!!!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Todd from Kewaskum, WI
Parts Used:
297216600
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
My Freezer Was Frosting Up, My Ice Maker Was Not Working ,And My Fridge Was Warm.
Had to remove all screws on rear back cover of freezer inside, unplugged refridgerator, uncliped thermostat, unpluged thermostat. Replaced thermostat with new one in the same location, and let defrost fulley. Reassembled, pluged in, and tested. All was good. But I did also replace timer at first part of the repair so I suggest you replace both at the same time.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Colline from PENDLETON, OR
Parts Used:
241798231
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker not making Ice
Unscrewed (loosen) screws lifted unit out unplugged electrical connection. plugged in unit hung on screws tightened screws and had ice in less then 1 hour. Rick
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Bowie, MD
Parts Used:
297013500
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Brackets for the food basket were broken and the basket alwaws fell off the track.
Removed the basket. Removed the two broken brackets (6 screws). Installed the two new brackets. Put the basket on the track. Done.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kelly from GILBERT, AZ
Parts Used:
241798231
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
made lots of noise
Loosen two screws, unplug power, lift it off, put new one on and make sure water chute is correct place, tighten screws!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Tehachapi, CA
Parts Used:
297216600
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Cooling coils would ice up and fridge would warm up
I removed the shelves in the freezer, took out the five 1/4" screws and lifted off the cover. It was a simple matter of using a blow drier to remove all the ice, then unplugging the two wires and unclipping the thermostat from the upper cooling tube. Then clipped the new one on and reconnecting the two wires.

Works great!!!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Janet from Stockbridge, MI
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer frozen, refrigerator warm
removed the screws/nuts; pulled the back panel off, removed the old thermostat (wires just popped apart) replaced the new thermostat (wires just popped back on) replaced the back panel and the nuts and TaDa!!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
henry from alhambra, CA
Parts Used:
241798231
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
my ice maker stopped working
removed ice maker storage holder and then remove two philip screws and unplugged four pin connector. removed ice maker and installed new one . very easy to do
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randolph from Edwards, MS
Parts Used:
297309000
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Evaporator fan not working
Took off cover, unplugged wires, removed old motor, mounted new motor, remounted new motor and replaced cover.

Now need a new control board for same model.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dmitriyev from Ruther Glen, VA
Parts Used:
297309000, 5308000010
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Evaporator Fan Motor burnt out because fan got stuck in frame wall during transportation
1st Turn off power. Removed freezer racks. Removed access panel to bottom back of freezer. Disconnect the wire harness to fan motor. Use 5/16 nut driver for removing fan motor from support. Removed fan blade from motor and put fan blade on the new fan motor. Bought new fan blades, but new fan blade would not work on new motor. Spring mount would fit on new fan blades, so I use the old one. Installed everything in reverse. Put everything back. Place thermometer in freezer. Freezer cooled down to -10F in 10 minutes. Great save on this one because I bought this freezer off of Facebook marketplace. Saved me $250. Good thing I know about fixing refrigeration equipment. Easy day.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
HAROLD from DETROIT, MI
Parts Used:
297216600
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
REFRIDGERATOR SECTION WANST GETTING COLD
freezer section remove ice trays ,shelves,unplug ice tray.use 1/4 nut driver remove back panel,use hair dryer thaw ice from evap coil ,unplug tstat remove install new one.plug in ice maker,put back panel back on ,ice maker and shelves plug refridgerator back in
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25344733105
46 - 60 of 142