Customer:
Tunis from NOLANVILLE, TX
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Patrick from RICHWOOD, TX
Parts Used:
242252603
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
The fan had stopped spinning. According to the internet it should spin freely if I use my hand, but it wouldn't.
After pulling the fridge away from the wall and opening the paper backing on the bottom, I could see the motor. It's affixed to 3 metal ribs by 3 small screw/nuts. There is also a 12" wiring harness that led to a simple disconnect. Removing the disconnect and the 3 nuts was easy. However, there was no room to remove the motor with the fan attached. Between frame parts, the drip pan below, the ribs, and small, delicate copper tubing that can't get bent, it wouldn't fit thru any openings. So we rotated the motor inside the framework until the blade faced out, then reached in with a pair of needle nose pliers to remove the washer. Removing the washer is easy, it's just difficult to reach. With the washer off the fan was out of the way and very carefully (it was tight) the motor came out. Reverse was the same issue. Motor tight going in, not a lot of room to maneuver fan onto motor, and needed needle nose to tighten washer again. Make sure you tighten the washer before you install the motor on the prongs. Otherwise you need to remove it from the ribs, twist it to face you, then reinstall it on the prongs. Also, I felt I was stripping the nuts into the new motor. Turns out the holes in the motor aren't tapped. i realized the nuts are self tapping once I looked at them. I'm a big time DIYer and this wasn't bad at all. If your motor/fan assembly comes out whole, it's even easier.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from SLIDELL, LA
Parts Used:
297216600
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer would frost up and not get cold enough to keep frozen.
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jennifer from BUFFALO, NY
Parts Used:
242252603
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Icemaker stopped making ice and i knew it wasnt the mechanism since I could hear that working when I unplugged and plugged the unit back on.
I found a couple of videos online of a similar product fix to get a lay of the land. When I got the part, I unplugged the unit and turned off the water. It was easy to take off the back panel and remove the old water intake valve to swap it out for the new one. Once I attached everything again I could see that the valve was taking up water but it didnt seem to be going all the way to the icemaker. I gave it some time and by the next day, there was fresh ice!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Micu from MOJAVE, CA
Parts Used:
241798231
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Every thing went smooth
But I have back ground mechanical skills, I did see the video one time, and everything went smooth......
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from GROTON, CT
Parts Used:
241798231
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker stopped working. Part needed to repair it no longer available so had to replace the whole icemaker.
Loosened the two mounting screws (no need to remove them), lift off the icemaker and unplug it. Reverse the order and done.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from INVER GROVE, MN
Parts Used:
241798231
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
8 loud pops and then dump ice .
Turn off power. Remove ice tray. Back out the two screws with nut driver and just lift ice maker off screws. Do not bend the water fill tube in the back . Now unplug the wire and remove ice maker .
To replace, match the color of wires on plug. Adjust wires in place and water fill tube and back on to the screws. Hold in place and snug screws. Turn power back on. In 4 to 5 hours your ice will start .
FED-EX UT to MN was 13 days to deliver .
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gary from ARANSAS PASS, TX
Parts Used:
5308000010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Victor L from ROCK HILL, SC
Parts Used:
IM116000
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Replaced icemaker
Old one bad, relpaced with a new one.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from KNOXVILLE, TN
Parts Used:
241798231
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker would dump ice one time and then stop. Turning the ice maker off for a minute and back on would repeat the process.
I removed the two side mount screws with a screwdriver and disconnected the electrical plug to the ice maker to remove it. I reversed the process to install the new one.

It was the thermostat that was the problem, but I chose to replace the entire ice maker for only $25 more.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack from WALLING, TN
Parts Used:
241639502
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.

If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.

In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.

Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.

Hope this helps someone. :)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from BROOKLYN, NY
Parts Used:
IM116000
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Old Icemaker kept jamming
Remove Ice container - loosen 2 Phillips screws -unplug electrical plug by squeezing sides- lift old icemaker up off the screws and remove - Plug in the new ice maker - place new icemaker so water inlet goes into new ice maker, slide up over existing screws and slide down - tighten screws and replace ice container
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from GUNTERSVILLE, AL
Parts Used:
242252603
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench (Adjustable)
Water inlet valve stuck open
Turned off water to inlet valve. Unbolted valve from back of unit, disconnect water supply line from valve, disconnected water line to ice maker. Put on new compression ring around water supply line. Pressed ice maker line into new valve, installed valve back on unit, then connected main supply line to valve. Works like a charm.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andy from GOOSE CREEK, SC
Parts Used:
218909912
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
warren from Farmdale, OH
Parts Used:
297013500
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken drawer slide
removed old broken part, 3 screws, then installed new part.....done
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!