Not Cooling
-Pulled refrigerator out to access back.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bert from SAN JOSE, CA
- Parts Used:
- WR60X30922
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little retaining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marie from Philidelphia, PA
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
replace filter
just had to unscrew old one put the new one in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from RINGGOLD, GA
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
compressor won't kick on
Pulled ice box away from wall. Took lower cardboard cover off. Shut water line off. Got my volt meter and checked the current going from the wall to the plug in at the inverter (input side), and I had the required 115 volts. Then I unplugged the connection going to the compressor (not the plug at the compressor which you cannot see until you unbolt the inverter) but the output connection side that goes to compressor. I checked the voltage and had about 13 volts not the required 115 volts. Therefore, I came to the conclusion that the inverter was bad. I ordered one from Partselect and they shipped it right away. I installed it and the ice box is back up to running order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Royce from Pasadena, TX
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Nothing to tell it was a replacement
Nothing to tell it was just a replacement part that the old part was removed and the new one inserted. Works like a dream Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Boyds, MD
- Parts Used:
- WR57X10024
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Solenoid wasnt pumping water to the ice maker
I started by shutting off the water inlet valve and then unplugged the refrgerator. I then disconnected the tubing leading into the solnoid. Removed the old solenoid, replaced it with the new part reconnectted the tubing and gave it a test run. After about 2 hours we had ice being made again! I then reconnected the bracket to the refrigerator and haven't had a problem since.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John M from SAN ANTONIO, TX
- Parts Used:
- WR60X10348
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Not cooling the bottom
Disconnect the refrigerator, remove & installed new fan evaporator motor
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from LAFAYETTE, LA
- Parts Used:
- WR02X11331
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Squeky Evaporator Fan
I made my wife fix it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from LA QUINTA, CA
- Parts Used:
- WR17X22070
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Replace water filter with bypass plug - filter is redundant with home osmosis system
If you have a reverse osmosis system for filtered water system in your home that also feeds the refrigerator, using another water filter in the refrigerator is redundant, so GE makes a Water filter Bypass Cap that allows you to run using the already filtered water without needing to expensive water filter. FIRST - using a phillips screw driver remove the toe kick plate at the bottom front of the refrigerator - two screws - one on each side of the plate that extends the entire width of the refrigerator. SECOND - Locate the water line (should be right in front) and the valve to turn off the water. Turn valve clockwise (right) until completely closed. Then test by attempting to fill a glass with water using the dispenser on the door. If any water continues to come out, continue turning the valve (without forcing it) clockwise until it has been turned as much as possible. If water still comes from dispenser, locate the source of the water line - most likely from under the kitchen sink. There should be another valve under the sink, or simply turn off (turn the cold water valve clockwise) until water cold water completely turned off. Test again as required. THIRD - clear the top right hand back shelf directly under the water filter screwed into the ceiling of the refrigerator in the rear top right side of the refrigerator. Place a small towel under the water filter, and slowly turn the filter 1/4 turn clockwise without using force. Continue turning until the full 1/4 turn is complete and the filter will drop down without pulling. Place the old filter upside down in the sink, thereby allowing the filter to drain any water present in the filter. FOURTH - remove the filter plug from package, notice notches in top of plug that align with gaps in the area where a filter would typically be screwed into the filter location in the ceiling above the top right shelf in the refrigerator. After aligning notches in the bypass plug with gaps in the screw mechanism, carefully turn the bypass plug 1/4 turn counter- clockwise - at which time the bypass plug should be firmly installed. FIFTH - Reverse step SECOND, and turn valve Counter-Clockwise until valve is completely open. Test to ensure no water is leaking from the Bypass Plug. SIXTH - Finally reverse step FIRST by reattaching the toe kick plate using the two phillips screws removed in Step FIRST. NOTE: The Bypass Plug is quite inexpensive, but after adding shipping from Canada - the cost is about the same as purchasing a new filter for the refrigerator. :-(
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RUSSELL from BLACK HAWK, SD
- Parts Used:
- WR17X1948
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
water line cracked
I loosened the compression nut on the valve with my fingers and pulled the water line free from the valve. On the other end, I just pulled it from the hose clamp. Installation in reverse. Force the water line into the fitting on top, Slide the old nut over the line on the bottom. Screw the nut onto the valve. Reach inside the freezer and turn on the ice maker. Done. Before replacing the cardboard grill, you should vacuum the coils on the bottom, front and back. If practical, push it outside and blow it out with an air compressor or a leaf blower.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROBERT from LA GRANGE, KY
- Parts Used:
- WR60X10348
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
old motor was making a clicking noise.
unplugged appliance. removed cover from back of fridge. unplugged wiring to condenser. pulled fan blade from motor. removed two bolts from fan bracket.removed fan blade and then motor. cleaned fan blade and all surrounding parts.installed new fan and blade. plugged fan motor back in re-installed cover on back of fridge.plugged fridge back in.motor is now nice and quiet.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter M. from Lincoln Park, NJ
- Parts Used:
- WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Myrtle Beach, SC
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Yearly replacement of filter
Moved stuff out of my way on the top shelf, reached in and turned old filter to remove. Filled new filter with water, lined up and turned to lock in place. Whew, never thought I would get that job done. :-)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from GREENSBORO, NC
- Parts Used:
- WR02X12008
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Fan was not centered in the middle of the back panel opening.
Bent the motor bracket down, then using a rat tail file, elongated the holes in the back panel of the refrigerator to secure the fan in the "centered" position. This was a problem that was with the refrig. since it was made. The parts involved were perfect. NO problem at all installing them.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from San Marcos, TX
- Parts Used:
- WR57X10024
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
water not getting to ice maker
changed both inlet valves, did diognostic on old ice maker. replaced with a new one from partselect.I have a cupple notes of interest. One, do not count on the instructions sent with part , I't took me a while to figure out that they do not necesarly apply to my unit. no diognostic light on new unit. and you don't have to follow the same procedures. I finished the project but the added help hindered me more than helped.
Was this instruction helpful to you?
Thank you for voting!