Customer:
Billy from Tooele, UT
Parts Used:
WS60X10004, WS22X10065
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
water leak at outlet pipe
turn off water & relieve pressure. Remove clips with needle nose.Separate softener from supply line assembly. Remove oring and clean with clean rag. Liberally apply silicone grease to oring & 0ring seat. I used stopcock grease non-toxic (Amazon.com) . You need this heavy grease. Join softener & supply line assembly. line up install clip with fingers. Turn on water & Check for leaks. I had a very very slow drip but it quit overnight. My second leak of this type, You probably don't need orings (expensive) Youwill probably only need the stopcock grease.. Key is turning off water and relieving the pressure. I tried it by using bypass valve only and broke a clip trying to remove it. You must relieve the pressure to remove the clip!