Models > GNSF23Z01 > Instructions

GNSF23Z01 General Electric Water Softener - Instructions

Jump to:

All Instructions for the GNSF23Z01
16 - 20 of 20
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Frank from Okemos, MI
Parts Used:
WS60X10004
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Would not recharge because metering turbine was jammed.
Followed diagnostic instructions in users' manual. Access to turbine requires disconnecting softener from water supply, so both brine valve clips must be removed. Not possible without breaking them. After that, the job was straight forward. Removed a small particle that was jamming the turbine, and reconnected. LESSON LEARNED: ORDER BRINE VALVE CLIPS BEFORE STARTING REPAIR.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ray from Gold Canyon, AZ
Parts Used:
WS22X10065
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers
Water leaking out of outlet O Ring
Had to empty all the Salt out of the unit to lighten it's weight so I could move it. Tried to remove plastic clips on O Ring area but broke one. Once clips were removed I pulled unit away from the by-pass valve and replaced and re-greased the new O rings. Pushed unit back and secured clips, finished. No Leaks!
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GNSF23Z01
16 - 20 of 20