LAT7800ABX Maytag Washer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Helen from NASHUA, NH
- Parts Used:
- WP89503
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Leaking water inlet hoses.
Removed the old hoses and screwed on the new hoses.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ellen from WILLITS, CA
- Parts Used:
- 205613
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Water overflow
The repair itself is fairly simple. However, being 65 years old getting the new valve back into the back opening of the washer and screwed in was a challenge. The clamp on the water connector hose broke and I had to drive to the store to replace it. You may want to consider giving a heads-ups option of ordering hose clamps to DIYers, when you go to order. Also, the instructions that came with the part was not totally accurate. I had to rotate the cylinders outward to connect to the electrical points. But, my machine is pretty old and that may be why. Otherwise, I am very pleased with how quick I received the part and it was exactly what I ordered. My washing machine is back in business. Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Thousand Oaks, CA
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Slow fill cycle - Hot water barely ran into tub during fill
First I unplugged the power cord from the wall. Then I turned off the water supply shut-offs at the wall and removed the hot & cold connections at the rear of the washer. Then I removed the two screws that held the assembly in the rear of the washer. I then pulled the assembly out about 3-inches, marked the new assembly to show the proper color of wire for each lug and disconnected the four wires at the lugs. I disconnected the rubber fill hose from the assembly and removed the assembly. Next, I installed the new assembly in the reverse order. It worked fine without any leaks & saved me from buying a new washer. My old washer now gets my clothes cleaner than it has for years - much quieter and quicker too.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kathy from Priest River, ID
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
Cold water barely coming in.
First thing I had to determine what was wrong. The machine had worked admirably for a 1980 model but over the last few years cold water input had reduced to almost nothing. There was also a slight hum during filling but it had been so gradual I really didn't recognize it as part of the problem.
After checking that the cold water faucet, hose and screens were okay I removed the front panel to see how water flowed inside the machine. I suspected the inlet valve on the machine was not working correctly so I looked on PartsSelect and found similar repair stories. I ordered one and it arrived in 2 days.
Repair was simple. Turn off hot and cold water and disconnect hoses from machine. Mine were on snug so it took pliers to get a turn started. Lay them in a pan to catch drippings. On the back remove the single nut above the inlet valve and lift to remove the panel. Remove the two mounting screws for the inlet valve. If needed rotate the electrical connections on the new inlet valve to match the old and transfer the wires. Remove the small output waterline and transfer it to the new valve. Mount the new valve to the panel and resecure the panel to the machine. Snugly attach the hot and cold water lines. Turn on the water and after checking for leaks you're good to go.
After checking that the cold water faucet, hose and screens were okay I removed the front panel to see how water flowed inside the machine. I suspected the inlet valve on the machine was not working correctly so I looked on PartsSelect and found similar repair stories. I ordered one and it arrived in 2 days.
Repair was simple. Turn off hot and cold water and disconnect hoses from machine. Mine were on snug so it took pliers to get a turn started. Lay them in a pan to catch drippings. On the back remove the single nut above the inlet valve and lift to remove the panel. Remove the two mounting screws for the inlet valve. If needed rotate the electrical connections on the new inlet valve to match the old and transfer the wires. Remove the small output waterline and transfer it to the new valve. Mount the new valve to the panel and resecure the panel to the machine. Snugly attach the hot and cold water lines. Turn on the water and after checking for leaks you're good to go.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from Madison, NJ
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
slow filling - both hot and cold
My Maytag A308 is about 25 yrs old and has been filling by a trickle for a while - both hot and cold. I replaced the water valve and that fixed the hot. Cold still running slow. I switched the hoses, thinking one might be clogged, and determined that the cold shut-off was clogged. I replaced that with a ball-valve - about $10 - and it works like it used to. My advice to anyone who installs a shut-off to any fixture - sink, toilet, w-machine, etc - NOT to use a cheap washer-type valve - they tend to freeze up over time and do not close when needed. Same for clean-out drain on hot water heaters.
Water valve on the A308 was accessible and easy to replace. Required rotation of solenoids was easy and connections were obvious. PartSelect
pictures were very useful and price was better than other on-line sources.
Ron
Water valve on the A308 was accessible and easy to replace. Required rotation of solenoids was easy and connections were obvious. PartSelect
pictures were very useful and price was better than other on-line sources.
Ron
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pedro from Miami, FL
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
The washer wasn´t loading the cold water when starting to wash, and that was affecting the whole running cycle
The replacement of the Water Inlet Valve supplied by PartSelect (model PS60378) was too easy.
The key issue was to remove previously the whole upper cover of the washer machine, including the Control Panel, and disconnect all the cables from the electronic Control Board, in order to work easy and freely to remove the inner water hose that is connected to the water inlet valve, working from inside and not from outside of the machine.
Care must be taken writing a notepad of the position of every cable, for not making mistakes when reconnecting them to the Control Panel.
The key issue was to remove previously the whole upper cover of the washer machine, including the Control Panel, and disconnect all the cables from the electronic Control Board, in order to work easy and freely to remove the inner water hose that is connected to the water inlet valve, working from inside and not from outside of the machine.
Care must be taken writing a notepad of the position of every cable, for not making mistakes when reconnecting them to the Control Panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Birch Run, MI
- Parts Used:
- 206638
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
water leak
Read repair stories on website. Removed front & top to find leak, Ordered part. Replaced valve. Had trouble with clamp.It only caught in first slot, then broke. Had to go to hardware for one slightly larger.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from ALLEN PARK, MI
- Parts Used:
- 205613
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The old inlet valve was not shutting off, causing the washer to overflow
I watched your 'how to' video, then repeated the procedure on my own machine. The repair went pretty much like the video. The new valve corrected the problem, and in fact, fills the washer faster than the old valve. I also replaced the water supply hoses, as one started to leak after I jiggled it around during the repair. Very satisfied with the this sites experience.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Adam from E STROUDSBURG, PA
- Parts Used:
- 205613
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Water keep filling up I had to shut water line otherwise the washer would have over flowed
Watched your video and followed your instructions and it was very simple.We bought our maytag washer in 1988 next year it will be 30 years old we raised 3 children and for $21 and your video I hope to it last another 30 years
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hector from Woodhaven, NY
- Parts Used:
- 206638
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
water leaking
Unplug machine and remove drain hose clamp and hose from rear of the machine.Using Phillips head screw driver remove the 2 screws from the lower front panel of washer. Lift and remove front panel. Using a small socket, remove 2 screws from the inside top left and right of machine which secures the machines top cover and lift cover up (use duct tape to secure washer lid from opening). At the inside rear top of the machine is the Siphon Break Connector. Loosen clamps, remove old Siphon Break Connector and install new one. Reinstall top cover, front panel and then drain hose.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tina from The Plains, VA
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Washer filling up with water when idle
I removed the two hoses connected to the valve, then I removed the front panel by removing two screws on the bottom. I disconnected a drum hose connected to the top, tilted the top back, then separated the inlet valve from its metal housing by removing the screws holding it in place. I then removed the metal housing in order to have more access to the old valve. At this point, the valve was only held in place by a few wires. I noted which wires connected where and how the valve was oriented (Hot/Cold position), then removed the wire connections with pliers by grasping the connectors (not the wires). I then reversed this process to install the new valve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from BROOK PARK, OH
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Washer would not fill hot nor cold water.
Followed video that came with part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from CARLISLE, PA
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Cold water keep entering the tub, I had to shut off the supply line.
I order a water inlet valve from this site It was the best buy around. The email from the site part came with a video how to change it. It was a 15 minute job. One 5/16 nut driver to remove the inlet valve and pliers to remove the hoes from the valve. Easy off easy on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Belleville, IL
- Parts Used:
- 205613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
overflow
removed cover, disconnected small water tube and disconnected electrical connections. Reversed above to install new piece. two nutdrivers required. Channel locks for supply hoses.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anne from Lexington, KY
- Parts Used:
- 205613
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
The fill stream on my 20 plus year old Maytag washer had slowed to a trickle. The hot water flow was fine, but the cold water flow was a trickle and there was a whining/groaning noise when the tub water was filling. We decided from reading other repair stories on your site that our washer had a mal
We turned off the water, removed the hot and cold water hoses from the machine, then unscrewed the metal plate on the back of our washer that was covering the water inlet valve. Next we removed the output hose and pulled out the inlet valve. As we unhooked each electrical wire we immediatley hooked it to the same location on the new inlet valve. Then we rehooked the out put hose and reversed our steps to finish the job. Before putting the plate cover back over the inlet valve we filled the machine with cold water and ran it through all cycles to make sure we didn't have any leaks. The pictures/insturctions that came with the new part were helpful.
This was the first repair job that our 20 year old Maytag washer has needed, and it was nice to be able to do the job ourselves. Reading other customers's repair stories on your web site helped us diagnose our problem. I found it easy to locate and order the right part and it arrived two days after being ordered.
This was the first repair job that our 20 year old Maytag washer has needed, and it was nice to be able to do the job ourselves. Reading other customers's repair stories on your web site helped us diagnose our problem. I found it easy to locate and order the right part and it arrived two days after being ordered.
Was this instruction helpful to you?
Thank you for voting!