Refill valve leaked continuosly.
Removed the hoses from the inlet valve. Removed screws that hold control panel in place . Removed control panel which exposed two clips that hold the top of the back panel. Removed the ground screw freeing the ground wire, removed the plastic loom which holds a bundle of wires. I next removed the plastic plate that protects the fill valve from splashed water. Removed the screw that holds the valve in place, then removed the wires and the fill hose. Reversed steps to put back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from San Diego, CA
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
The water inlet valve was defective
First I turned off the water to the washer and then removed the hot/cold water hoses going to the washer, unscrewed the water hoses from the washer, and cleaned the wire screens located immediately inside the inlet water valve. This did not solve the problem. Second, I loosened the hex head screws on the back panel of the washer. This allowed me access to the valve. I tested the valve solenoids with my ohm/volt meter and all checked out OK (but this did not make sense). Third, I surfed the web to find out if the symtoms of the washer's problem were the same as experienced by other people. I found several reports of the same symptoms, all which were solved by replacing the water inlet valve. This conformed my original diagnosis although the valve tested as OK. Fourth, I ordered the part from PartSelect, and removed the hose clamp and two mounting screws holding the old valve to the back panel of the washer and removed the old valves. Last, when the new valve arrived, I assembled the new backing plate to the new valve, attached it to the washer's back panel, attached the water hoses to the valve after fitting new rubber seals to the inside of the hoses, and reattached the washer back panel. The washer is working perfectly again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joselin from Port Saint Lucie, FL
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
Only hot water would be dispensed into the washing machine
took off the rear panel and removed the existing inlet valve and installed the new one. Replaced the rear panel and the machine work better than ever.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Nanuet, NY
- Parts Used:
- W10820036
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
washer would fill with water but not start
took part top of washer saw switch replaced it not to difficult it is always easier when you have new one to look at
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Sterling, CT
- Parts Used:
- 285805
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
My washing machine overflowed and flooded the basement
First, I unplugged it and disconnected the water hoses (the water has been off to it for days). Then, I tried taking off the back of the washing machine. This didn't work, and I actually ended up googling instructions and found pretty detailed, illustrated instructions at Popular Mechanics.
You need to unscrew the front panel that contains all of the controls first, flip it up, and unhook it from the back of the washer (via an electronics clip and 2 metal clips). The outer cover can then be taken off. I recommend undoing the internal hose next -- I used adjustable pliers to squeeze the connecter and loosen the hose. Then, unscrew the water inlet valve and take it off.
Putting everything back together literally just means reversing the instructions.
My washing machine is on a raise service, and I still haven't gotten the outer frame completely back in place correctly, but it's not touching anything or creating any problems. It's really only to safeguard parts anyways, so no worries if it's not perfect -- at least it works now!
You need to unscrew the front panel that contains all of the controls first, flip it up, and unhook it from the back of the washer (via an electronics clip and 2 metal clips). The outer cover can then be taken off. I recommend undoing the internal hose next -- I used adjustable pliers to squeeze the connecter and loosen the hose. Then, unscrew the water inlet valve and take it off.
Putting everything back together literally just means reversing the instructions.
My washing machine is on a raise service, and I still haven't gotten the outer frame completely back in place correctly, but it's not touching anything or creating any problems. It's really only to safeguard parts anyways, so no worries if it's not perfect -- at least it works now!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rick from Lennon, MI
- Parts Used:
- WPW10001130
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench (Adjustable)
Bought a washer without front leveling feet
The repair was simple as you can imagine. Thought I could buy these legs at any big box store or at least at the local hardware store. No such luck. Partselect had the right product---easy to order and easy to install. Things around here are great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from cleburne, TX
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
squealing noise, very little cold water to fill tub, hot water normal
turn off hot and cold water faucets,unplug the power,pull washer out to gain access to rear cover, remove the top control panel screws,push back and lift off, disconnect hot and cold water hoses from inlet valve and remove enough screws from the back panel to remove the valve, disconnect the valve from the tub fill hose (mine had a spring type hose clamp) note the orientataion of the hot and cold hoses and the solenoid connectors for the hot and cold sides,(mine is stamped in the rear cover)reconnect and reassemble in reverse order and check for proper operation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Edgerton, WI
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Water inlet valve would not shut off on cold side.
I removed the faulty valve after unplugging the AC cord. Two screws, the two water hoses were removed, and the electrical connections were unplugged. The old valve could then be rotated so that the clamp on the fill tube could be loosened and the tube pulled off the valve.
The new valve body seemed to be an exact replacement, but the mounting bracked was slightly different and required drilling two new screw-mounting holes; an easy job.
Before securing the mounting plate to the machine, the fill tube and clamp were reattached, and the electrical connectors plugged in. After connecting the supply hoses and plugging in the AC cord, the machine filled with water properly and everything seemed to be back to normal.
I might have been able to use the original mounting plate, but it had been taken to a different location which was too far away to easily retrieve.
The new valve body seemed to be an exact replacement, but the mounting bracked was slightly different and required drilling two new screw-mounting holes; an easy job.
Before securing the mounting plate to the machine, the fill tube and clamp were reattached, and the electrical connectors plugged in. After connecting the supply hoses and plugging in the AC cord, the machine filled with water properly and everything seemed to be back to normal.
I might have been able to use the original mounting plate, but it had been taken to a different location which was too far away to easily retrieve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Valan from Arlington, TX
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Had no hot water flowing into the washer.
I just followed the instructions from a previous customer. Worked perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andris from Sands Point, NY
- Parts Used:
- W10820036
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
Dryer would not activate
>removed 2 screws connecting the vent filter to the top lid of the unit (just in front of removable filter).
>Losing two screws at the back of the machine, just below control panel to allow free movement of the top lid on its hinges.
>Raise top lid & supported open.
>Now have free access to door switch (inside , front right fastened to front panel)
>removed the old switch
>fasten new switch (required new wire connector which was supplied with package) to existing wiring and replaced.
>Works perfectly!
>Losing two screws at the back of the machine, just below control panel to allow free movement of the top lid on its hinges.
>Raise top lid & supported open.
>Now have free access to door switch (inside , front right fastened to front panel)
>removed the old switch
>fasten new switch (required new wire connector which was supplied with package) to existing wiring and replaced.
>Works perfectly!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- walter from palmetto, FL
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
water inlet valve would not shut off because of warn out part
Take top of washing machine off. Turn spikets off and remove hot and cold inlet hoses. Remove one screw holding part in place. Reach from front and take valve out. Unplug wiring harnesses. Reinstall the same way I took it off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Royse City, TX
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
No hot water & very little cold water
As I tore my ACL, my wife actually did the actual repair while I talked her through it. The video on your website was such a great help. Our repair went exactly as depicted.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Walter from Palmerton, PA
- Parts Used:
- 285805
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Won't stop filling with water
Loosing back cover to reach in and remove valve
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BRIAN from NEW ORLEANS, LA
- Parts Used:
- 285805
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
machine stopped running hot water
replaced valve. Everything now working. Ordering the part was simple and I found a how to video on line that was great The whole replacement of the defective part was easy and the machine was back on line in 30 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from Burbank, CA
- Parts Used:
- 285805
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Cold water barely filled the tub.
I replaces the water inlet valve and now I have full pressure for the cold water to fill the tub.
Was this instruction helpful to you?