Customer:
Christian from Saint Augustine, FL
Parts Used:
WH13X10023
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
The washer would not stop running water, even when unplugged!
The cycles were taking forever, then would not finish, water running in even when it was supposed to drain. Unplugged washer and water would still run, I had to turn off the water valve. I just removed the top with phillips screwdriver, removed the old valve by uncoupling the water hose, the two electric connectors and the two one screw holding it in place. It fixed the problem completely, washer working 100% now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jonathan from Oviedo, FL
Parts Used:
WH13X10023
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
water would not stop filling in machine even when it was unplugged! !
Step 1- pull washer away from wall. Step2- unplug power, shut off water and disconnect lines, and disconnect drain line. Step 3- unscrew 3 screws from bk and 3 screws from behind control panel. Step 4- remove back of control panel and top of washer. Step 5- unplug wires from old valve and plug into new valve to avoid wrong connection take out screw from back releasing old valve , insert new valve and put back screw. Step 6 put top of washer and back of control panel on and insert screws. Step 7- reconnect hoses and drain , plug washer in and test. All done. I recommend adjusting to level if necessary at this point before pushing back against wall. Good luck. Hope this helps somebody. Jon
Was this instruction helpful to you?
Thank you for voting!
Customer:
RON from APPLE VALLY, MN
Parts Used:
WH13X10023
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Hot water hose leaking, it was cross treated (twice) by the installer, would not warranty it the second time.
Followed your instruction, very easy. I installed Camco 90" & 45" Brass elbows to relieve strain on hoses.
Was this instruction helpful to you?
Thank you for voting!