Models > ATGE9ASP115TW01 > Instructions

ATGE9ASP115TW01 Speed Queen Washer Dryer Combo - Instructions

Jump to:

All Instructions for the ATGE9ASP115TW01
16 - 30 of 178
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
PHILIP from LONG ISLAND CITY, NY
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Time clock not moving .Not enough heat
Opened front panel .Tested both coils on gas valve.
Found no continuity on one of the coils. Replaced coil,
dryer works like new.
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from North East, PA
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Burner would not go on on my Stack Set Dryer
Took out two front Panel screws and removed the panel. Removed Gas solenoid coil holding bracket by removing two phillips head screws. Disconnected the coil leads. and removed the coils. Connected the new coils to the leads and set in place. Replaced the holding bracket and the two screws. Replaced the front cover and the two front cover screws. Piece of Cake!
16 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Bradenton, FL
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
The Dryer would not get hot.
I removed the two screws holding the access panel, and removed the access panel. Then removed the lower air duct. I then checked the burner, The solenoid was not opeing the valve for the gas. I order the coils, in two day I had the coils and installed them. The dryer is working great.
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Chicago, IL
Parts Used:
279834, 279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Socket set
The dryer was not fully drying
After replaceing several parts including the thermostats the last part I replaced the coils were the defective part. I originally metered out the themostats and they appeared to be okay but since this was my first time I thought I might have been mistaken. It turns out the last part I thought it could be was the part that was defective. I will say that it is very simple to replace any of the parts involved. The hardest part was trying to open the dryer itself. But after having to do it 3 times, I'm now a pro. I also replaced the drum belt and since I had it open I also replaced the belf idler with a newer modified idler rolller.

Putting the belt back on is easy, but it helps to view the video or a picture to understand how the belt goes around it.
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from New Windsor, NY
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
dryer not heating up
Unscrewed 4 screws,pulled off front of machine.Unscrewed 2 screws holding coils on,unplugged coils,installed new coils,plugged in coils,reinstalled 2 screws for hold down brace.Reinstalled front cover,plugged dryer into outlet(remember to unplugged dryer before working on it).started up,instant heat,works great.thanks Partselect for helping me out!!!
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Foothill Ranch, CA
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Gas Dryer would heat for one heating cycle but no gas afterward. Ignitor would glow.
Checked four thermocouples all showed continuity with my multimeter so they were all good. I'd read that the coils commonly went out and that these were the symptoms. Hey, it's very simple in there. Not much else could be wrong. I had a Maytag repairman come out. At first he said the problem was a blocked vent. I knew he was wrong. Then he said one of the thermocouples went out. It was $80 for him to come out. It turned out that his second diagnosis was wrong too. To repair the dryer by Maytag would have cost me $240. I gave him $80 and bought the coils for $37. They are EXTREMELY easy to replace: two screws held a bracket that held two coils. With the bracket off, I took off the old coils and slid on the new ones.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roger from Westminster, SC
Parts Used:
279834, 279834
Difficulty Level:
Very Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Close would not get dry. Dryer started normal. Timer would not time out.
Getting to any of the parts in the Maytag dryer is easy. Tip the dryer back and slide a 4 x 4 block under the front edge. You remove the whole front panel after you remove two screws at the bottom corners of the front panel. You need to tip the dryer back to get a screwdriver on the screws. Swing the front panel up to release the top of the door panel from the top. Watch the short wires to the door switch. Unhook the door switch wires and move the front panel out of the way. The timer on the top is accessed by re-moving two screws along the top edge. There are four screws. Remove them all and tip the top of the front panel forward. You then see that two screws hold the panel and the other two screws just hold the trim.

The dryer started normal. The drum motor run when the start button was operated. The fluff cycle operated normal to indicate the timer motor was OK. On the dry cycles, the igniter heated up. The gas came on. The dryer run for some period of time and then the flame went off. The thought was that the low temp cycle thermostat sensed the dryer was hot and thus switched over to time the cycle to its end. However, the low temp cycle thermostat tested good with a meter when the sensor was removed from the dryer and heated with a light bulb. Burnt contacts in the sensor were a possible problem. I also though the radiant sensor may be bad and not recycling after it got hot. After time, the igniter would cycle on but the gas flame would not come on. I thought the radiant heater might not be tripping the secondary coil on the gas valve. The gas valve coils tested good. I was checking them cold after the dryer had cooled down. I ordered a number of parts.

I got lucky and did a test on the coils while the dryer was still hot. One of the coils in the dual booster holding coil was going open when hot. When cold it had enough continuity to let the gas valve cycle on once. After the coil got warm it went open and shut the gas valve off. When the coil did cool off, it again had continuity. I was about ready to trash the dryer when I finely found the problem. I am happy I persisted and worked the problem through to a solution. I purchased several extra sensors but saved money in the long-run. I rate this problem at the high end of complexity for the do-it your self home owner to solve. The problem was an easy fix once the real problem was found. Only 4 screws and 3 push on wire connectors (two were on the front panel for the door switch).
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Glenn from Ossian, IN
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set, Wrench set
gas dryer would fire, but shut down before getting warm enough to dry clothes
Removed lower front cover of dryer, located coils, removed old coils by disconnecting the wires and removing the hold down bracket screws. Pulled the old coils out replaced them with the new coils by aligning the index pins on the coils with the holes in the bracket then reattached the bracket and plugged the wires into the new coils. Then closed the cover on the front of the dryer. Dryer now ignites and stays on to heat up and dry clothes.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Manuel from Jurupa Valley, CA
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Dryer not Drying
Replaced both Coils. Purchased M Series coils much less expensive buying coils together instead of seperately. Problem solved.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
lawrence from GROTON, VT
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
No Heat After 10 Minutes
Shut off gas removed gas valve. Removed the coil retainer and installed the new coils. Reinstalled valve and checked. Found dryer worked fine.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rob from Henderson, NV
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Dryer would only heat at start up for one cycle
Ohmed coils and both had continuity so I changed radiant heat sensor. No bench test for Radiant Heat sensor. Same problem. Changed both coils and dryer works fine. Weak coils were my problem. I read thru the same issues in Parts Select forum and it said Radiant Heat sensor was problem 25% of the time. With coils having continuity and no ohm value specified for coils I made wrong choice but, I have spare parts and look for another 10 years of life in the dryer. Nice to have this forum to research appliance repair. Very helpful for parts location and installation. Dishwasher is next!
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from cedar lake, AL
Parts Used:
279834, 279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
not drying all the way, not getting hot enough
loosened two screws on back of top,lifted top away from front panel.it just lifts off front corners,removed two screws at top corners.lift front panel up and out,this panel supports dryer tub,remove slowly,unplug door switch parts are located left side bottom two screws holding in had to have wife hold drum up to put front panel on
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Chicago, IL
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Dryer would not heat up properly. It would heat initially but once the heat was off it would not come on again.
I followed the advice posted by other customers. I took the front off the dryer, put the door back in place and ran a cycle. I could see that the igniter was heating properly, but no gas was flowing. Based on what I read I concluded that it was a problem with one of the gas valve coils. It was relatively inexpensive to replace both (and the dry is 10 years old), so I didn't go to the trouble of determining the bad one. I replaced them both. Obviously I unplugged the dryer (no need to turn off gas). There were 2 screws that held the bracket in place which holds the coils. I disconnected the coils, removed the bracket screws, replaced the coils, reattached the bracket screws and reconnected the coils. I then reattached the front plate to the dryer. It was very easy and took about 20 minutes and I had never worked on a dryer before.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Sacramento, CA
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
No Heat sometimes, But for a moment then None
First and Foremost i was told that my problem was with the Thermal Fuse (Fix Ya.com), Then with the little Electrical knowledge I have thought Fuses don't turn on and off,If the fuse was bad i would get No Heat. (Even for a second) Fuses just don't turn on and turn off intermittently,when they go there done! So after a little research i decided to order the gas coil valve. I tilted the top up, two screws on the front panel, took that off and the valves were exposed,(bottom left) two screws too remove bracket then installed new coils on bracket,put back together and I Have Heat Again! NO problems what so ever since new install. I would say having not been for cleaning lint build up inside the machine (been 6 years) the Whole project took me Ten Minutes.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Chicago, IL
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Gas dryer would not heat - pilot lit briefly then went off
Same as others.
1. Unplug dryer from power source
2. Use nut driver to remove two front screws at bottom of dryer
3. Disconnect cable connected to Secondary Coil (this is the coil towards the rear of the dryer)
4. Use angled phillips screw driver to loosen screws holding cap on top of the two coils. (Angled tool not required but seemed easiest to me)
5. Slide top cap back towards lock screw to allow coil to be lifted out
6. Remove and replace secondary coil
7. Replace cap, tighten screws to lock in place, reconnect cable to coil
8. Restore power to dryer, test and confirm gas flame stays lit
9. Replace lower front panel on unit

PartsSelect a great resource to use for home repairs like these. My first time using site and doing this type of work, now PartsSelect my first source to go to on such items.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ATGE9ASP115TW01