- Customer:
- Harry A. from Maitland, FL
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers, Socket set
Agitator stopped turning with a load in it.
Pulled cap off top of agitator, loosened bolt down in center of assembly and pulled collar up with pliers.
Removed old dog ears and replaced. Need to be extra careful on direction of dog ears.
Very simple; even a cave man could do it!
Removed old dog ears and replaced. Need to be extra careful on direction of dog ears.
Very simple; even a cave man could do it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Clawson, MI
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Agitator was spinning freely
Removed the fabric cone from center of agitator pop out the plastic cover inside, remove bolt in center pull on agitator, remove cam holder and replace cams.
repeat process to re assemble
repeat process to re assemble
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kitty from Erie, PA
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
Agitator wouldn't turn when washing clothes.
Removed fabric softener dispenser. Inserted medium flathead screwdriver into slot on side of cover that is on agitator and pried off. Used socket wrench, socket and extension to unscrew bolt inside agitator. Lifted out and slid off plastic ring holding agitator cogs (cogs will fall right out so make sure you check to see how they're in). Replaced cogs in the same direction they came out. Very simple!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tanya from Garrettsville, OH
- Parts Used:
- WPW10072840, 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
agitator not working (again)
The dogs (directional cogs) cause the upper portion of the agitator to turn in one direction only. The clothes don't get clean unless this happens.
The material the dogs are made of wears out in a few months of use.
I buy 4 packages of them at once, every few years.
Pull off the inner cap, unscrew the bolt, remove the old cogs, put in the new ones, reverse the disassembly process and away we go.
The material the dogs are made of wears out in a few months of use.
I buy 4 packages of them at once, every few years.
Pull off the inner cap, unscrew the bolt, remove the old cogs, put in the new ones, reverse the disassembly process and away we go.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Cincinnati, OH
- Parts Used:
- 285751
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
The upper agitator would not work.
Pryed off the upper agitator cap, unbolted the agitator, lifted it out, replaced the dogs, and put it back together. A very easy home repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Plainville, CT
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers, Socket set
two halves of agitator no longer had enough friction to bind in one direction
disassembled two halves, cogs just sitting there, replaced, re-assembled
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tammy from Wildwood, FL
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
The agitator cogs were worn out.
We took off softner cap and then took off the agitator with a nutdriver and then pulled the top off and the central agitator that the cogs were in pulled it out took the cogs out and replaced them with the new ones . Then we put the agitator back on and tightened the nut and replaced the softner cap and we were all done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Greenville, WI
- Parts Used:
- 80040
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
Agitator upper half didn't ratchet with the agitator motion
To replace the dogs that cause the ratcheting motion:
I removed the softener cup by pulling straight up. (You've probably found, as I have, that the softener cup and the bleach dispensers are problematic: the softener cup must be cleaned with every use or the old softener liquid turns to glue, and the bleach dispenser mechanism plugs and distributes bleach onto your next load, ruining entire loads of clothes.)
Then I lifted the cap covering the retaining bolt by inserting a screwdriver alongside in the square holes provided, loosening it, and lifting it out.
Then I used a socket and a very long extension to remove the retaining bolt. I lifted the agitator straight up.
The next step can be a problem: I survived it (though I did strain my back). What's required, as you can see by reading the preceding letters, is to lift sharply on the upper agitator while holding the lower agitator with your bare feet or some soft shoes. What this does, at least on my model, is to break off the tabs that are fused together over the ratcheting-dogs, which are the focus of the repair. (These tabs hold the upper and lower assemblies together, moving the dogs assembly with the lower agitator.) In my case, one of the tabs broke off a half inch below the top, but that wasn't catastrophic and I didn't lose the rest of them, so when I reassembled the two halves still snapped back together.
One problem was that when I jerked the two assemblies apart, the parts of the dogs assembly went flying. Everyone had said to make sure everything went back the same way it came apart--for me there was no way to tell what that way was, but common sense tells you which way to reinstall the new dogs; they have to catch every stroke.
To reassemble, position the dogs with the retainer cup inverted. Then hold them upside down while sliding the upper agitator down over them. This holds them in place. When sliding the upper agitator down onto the lower, make sure the slots line up and use a smooth even pressure. Snap the two halves together, bolt the agitator back into the machine, replace the cap with the large o-ring (make sure you clean and/or replace the o-ing), and reinstall the softener cup.
Et, voila! You're back in business.
I removed the softener cup by pulling straight up. (You've probably found, as I have, that the softener cup and the bleach dispensers are problematic: the softener cup must be cleaned with every use or the old softener liquid turns to glue, and the bleach dispenser mechanism plugs and distributes bleach onto your next load, ruining entire loads of clothes.)
Then I lifted the cap covering the retaining bolt by inserting a screwdriver alongside in the square holes provided, loosening it, and lifting it out.
Then I used a socket and a very long extension to remove the retaining bolt. I lifted the agitator straight up.
The next step can be a problem: I survived it (though I did strain my back). What's required, as you can see by reading the preceding letters, is to lift sharply on the upper agitator while holding the lower agitator with your bare feet or some soft shoes. What this does, at least on my model, is to break off the tabs that are fused together over the ratcheting-dogs, which are the focus of the repair. (These tabs hold the upper and lower assemblies together, moving the dogs assembly with the lower agitator.) In my case, one of the tabs broke off a half inch below the top, but that wasn't catastrophic and I didn't lose the rest of them, so when I reassembled the two halves still snapped back together.
One problem was that when I jerked the two assemblies apart, the parts of the dogs assembly went flying. Everyone had said to make sure everything went back the same way it came apart--for me there was no way to tell what that way was, but common sense tells you which way to reinstall the new dogs; they have to catch every stroke.
To reassemble, position the dogs with the retainer cup inverted. Then hold them upside down while sliding the upper agitator down over them. This holds them in place. When sliding the upper agitator down onto the lower, make sure the slots line up and use a smooth even pressure. Snap the two halves together, bolt the agitator back into the machine, replace the cap with the large o-ring (make sure you clean and/or replace the o-ing), and reinstall the softener cup.
Et, voila! You're back in business.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Ramsey, IL
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Agitator cogs were wore out
I just took the bolt out of the top of the agitator which allowed me to pull the agitator straight up. Then I turned it over so the sleeve that the cogs go into could fall out. I took the old cogs out, put the new cogs in, held it upside down and lowered the agitator down onto as to not move the cogs. When it was all situated correctly I held it by the bolt as I turned it upright. Then I just lowered it back down in place inside the drum and tightened the bolt back down. Done.
The washer works just like new.
The washer works just like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Austin, TX
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench set
Agitator quit agitating
Took the cap off the agitator, loosened the nut with a wrench, and pulled the agitator out. The agitator pulled apart easily, revealing the piece containing the dog ears, which were clearly worn out. Simply replaced the dog ears and reinstalled the agitator. Piece of cake!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ZHAN from MORRISVILLE, NC
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Agitaor does not spin anymore
First take the top cover off, second using socket to turn the nut loose at the center, then removing the plastic holder which has four directional cogs in it, replacing them with new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marius from Buena Park, CA
- Parts Used:
- 80040
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Socket set
washer would not agitate
basically pop off the top spindle cover, reach in and pull off the water cap from the agitator cog cover, unscrew the bolt holding the cog holder and pull the agittator assembly up and off the machine. Remove the piece holding the gogs in place and replace cogs making sure to put them back in the same direction as they came out. Turn the agitator upside down and stick the piece holding the cogs in and snap it in. Replace all components in reverse order they were removed, and there you are. Works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Lakewood, CA
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Top part of agitator was skipping/not turning
First I removed the pop off cap at the top of the spiral shaped top agitator. Then reach down inside and pry off another pop off water tight cap exposing a 7/16 or 1/2 inch nut. A deep socket would probably be easiest but I didn't have one so a nut driver and luck got it unthreaded- it was pretty tight and yoiu have to hold the agitator from spinning while you unthread. Then the upper agitator asslembly lifts out and the cog assembly falls apart but it's only like 3 or four housing pieces and it only goes together one way to hold the four new cogs in place. reassemble and the machine works great again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wilber from Thomaston, ME
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
wouldn't agitate properly
I removed the fabric softner dispenser,removed the inner cover,removed the 1/2" bolt holding the upper agitator to the lower agitator and pulled the upper agitator up and out.Remover the cog holder from inside the upper agitator and replaced the old cogs with the new.They simply set loosely in the holder.I then reversed the process of putting the agitator back and bolting it in,inserted the small cover and dispenser.The entire job took about 5 minutes at most.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Durand from Tyndall AFB, FL
- Parts Used:
- 80040
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Agitator would'nt agitate
Took off softner dispenser, took off bolt cover. Used 7/16 socket with long extension and unscrewed bolt. Pulled up on agitator and out it came. Took out directional cogs and replaced with new. Reversed procedure and I was done. Saved a lot of money by not calling a mobile repair man on this one!
Was this instruction helpful to you?
Thank you for voting!