Richard from Blue Ridge, TX
Parts Used:
1129316
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker motor excessive slip (essentially worn out) & contacts were worn
1 removed bottom off old ice maker (3 hex screws) and ice drop shield (white plastic ice flips over into ice holder, old unit had different drop angle, see how described below, but I just musled it off the old unit) 2 removed "ice sensing bar off new ice maker and rotated mechanical sensor to on (leatherman tiny flat head) 3 removed end cap from new ice maker, then loosened to large screws (Phillips, leatherman) for motor unit cover. This allowed removal of ice drop shield on new unit (two tabs, one at each end). 4 removed ice drop shield and installed old ice dropshield on new unit 5 tightened two endcap screws (Phillips/leatherman) and reinstalled end cap 6 installed old bottom unit/tray on new ice maker (3 screws) 7 ensured wiring matched and routed plug properly 8 installed unit slides in 9 plugged unit to existing plug 10 installed old wiring shield (1 hex screw). Waited two hours to verify water valve worked properly, although IR codes did indicate "okay". Machine has been making ice and IR sensor shuts it off properly. So far a success. I have many spare parts if I need to do further repairs including a new water solenoid. Only saying it was a bit difficult because of the parts exchange, in actuality for me it was really easy.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Monroe, MI
Parts Used:
WP2196157
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Water fill tube broken
removed two screws and pulled part out of the unit. The local appliance store said they needed model and part # to try to identify and order the part. Found part select online, found the part immediately, ordered the part for $4.50 or so. Part was delivered in 2 days! Very easy installation and the part works perfectly. Thanks so much!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Crete, IL
Parts Used:
WP2196157
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
The water fill tube 90 fitting broke
Removed brokent tube fitting from the compression nut.
Removed two screws holding the fill tube. Removed and replaced the fill tube. Direct replacement, no cutting tube length. Reconnect water line to the new fill tube.......Done.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Holden, MA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ted C from DSRT HOT SPGS, CA
Parts Used:
WP4387503
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Drain clogging causing water to leak bottom of fridge
After watching videos how to replace went very easy.removed ice maker cut wires replaced switch put back together now working ok so far.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from HOUSTON, TX
Parts Used:
4387478
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Faulty light socket
Followed the video instructions.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carmela from Lincroft,, NJ
Parts Used:
4386917
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The panel on the freezer door broke
I followed the directions that came with the new part. Thank you for making it so easy. You sent me everything I needed to make the repair.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Diane from Brighton, MI
Parts Used:
WP4387503
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Ice buildup in freezer causing leaking water into fridge section
In my case the defrost thermostat was not the problem. Not worth going through the hassle of checking the thermostat as I would have had to cut it out and test it in another freezer (while the food that was in the freezer was being stored elsewhere). I just ended up buying it and replacing it. So, like I said the defrost thermostat was NOT the issue. I ended up getting a drain tube heater strap, and have been keeping my eye on the fridge. It hasn't been long enough to say the strap fixed the problem, but all indications are pointing to that being the case.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karl from Wellesley, MA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jay from Mt. Pleasant, WI
Parts Used:
WP2196157
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Broken plastic part at top of water fill tube to freezer
Simple. 1st, removed broken part to understand part (water fill tube to freezer, plastic part at top of fill tube cracked). 2nd go on your web site and look at prints to find part number, Study video to understand video. 3rd. Called customer service and lady was very nice and efficient. Placed order and received. Study video again and installed. My 9 year old grandson was visiting from out of town and assisted in installation. Just over 30 minutes to install
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Farmington Hills, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MIKE from ARLINGTON, OR
Parts Used:
482731
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Mounting bracket was riveted on old motor, mounting bracket holes on new motor were different
removed shims on screws holding motor together, enlarged hole in mounting bracket so motor screws could also go through mounting brackets.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
franz from fairlee, VT
Parts Used:
2188447A
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
refrigerator doorseal
remove braketts holding seal , install new seal.
9 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Granada Hills, CA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from MARYLAND HTS, MO
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
freezer (later fridge too) wouldn't stay cold~
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
2 of 3 people found this instruction helpful.