Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
edna from las vegas, NV
Parts Used:
4388538
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Shelf support stub for crisper broke
I had read here from someone that fixed there shelf support stub and it was very loose, so I was trying to advoid that problem. It took me less then 5 minutes and my only tool was a pair of pliers. A short turn clock wise from the 9 on a clock to the 12 ( which is the top left corner ). then pull the broke shelf stub straight out. Put the new shelf support in the same way you took the old one out and turn counter clock wise 1/4 or from 12 back to 9 and you should have a tight fit. I hope this helped.
24 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Westlake, OH
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
refrigerator was intermittently cooling because thermostat contacts burned away.
Turn off the fridge and unplug the power. Inside the refrigerator unit, remove two plastic panels extending from the front to the rear cooling vent by unscrewing two screws. Gently unhook the thermostat tube from the rear vent.

On the control panel, gently pry off the two control knobs and the front control panel. Remove four screws to drop down the control assembly. Unplug the left electrical connector and unscrew the lever control arm being careful not to bend it. Disconnect the right side electrical connector and you can now remove the control unit to a table to easily work on it.

Undo two screws to remove the thermostat bracket. Undo two more screws to remove the thermostat assembly. Install the new thermostat and reverse the process just described. It takes about 15 minutes if you know what to do ahead of time. You will have to reuse the plastic tube that covers the thermostat sensing tube.
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laurence from Middleton, WI
Parts Used:
W10190935
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
plastic gear broke off - cubes not getting kicked out
removed the three screw holding the broken unit - pulled off the old module.

Before I could install new module I had to loosen some fasteners on ice maker so I could turn shaft to align with new module.

Then push on new unit and three screws. Had tumbling ice in about an hour. My wife thinks I'm a hero. (I am)
23 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Coppers City Bottom, WV
Parts Used:
4389144, WP2169142
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The fan wasvery noisy.
Removed six screws from cover in the back of the freezer. Removed old fan . Removed power wires from old motor. Unclipped old motor from the mounting bracket. Replaced old motor and reversed the rest of the parts. Done
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
haig from La Quinta, CA
Parts Used:
WP4388152
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Wrench set
in door water dispenser tube broken off 1.5 inches from end
shut off water supply behind fridge then released trapped water pressure in the line at the dispenser. Locked off dispenser controls (push button switch). Removed nozzle retaining screw and pulled out nozzle approx. 3 in. to cut off tubing at black pipe so as to use the old pipe as a guide/pull (fish) for the new pipe by joining the end of the new nozzle to the cut and of the old pipe with electrical tape.Then pulled the old pipe from bottom of fridge while simultaneously feeding/pushing new pipe from top. I had to remove lower grate on fridge to access the pipe on bottom. Remaining coupling connection on bottom was done by hand to avoid stripping plastic coupling.
23 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Franklin, TX
Parts Used:
W10822259
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Noticed fridge not cooling as it should
Removed the lower back panel (10 small screws)Found the condenser motor froze up and not moving air across the cooling coils.So I got a small table fan and set it behind the fridge and it kept the fridge cooling for 3 days till the new fan motor arrived. Removed 3 small screws holding the fan motor in the bracket and unpluged the wiring harness.Removed the fan from old motor and used it on the new motor.Replaced the fan in the bracket and plugged the wiring harness back in. Worked great. Very easy.Did not have to empty fridge because table fan kept coils cool. Ordering part was easy and shipping fast.Great job guys!!
21 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason from Farmland, IN
Parts Used:
WP2188664
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken drawer
Put new drawer in fridge.
22 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Murfreesboro, TN
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Fridge side freezing everything.
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control box to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
21 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barb from North Royalton, OH
Parts Used:
2188405A, 2188404A
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Refrigerator came with house my daughter purchased and needed new seals. Refrigerator is 17 years old.
First, I read your instructions on line about how to replace a refrigerator gasket and freezer gasket. We replaced both. The information was extremely helpful since we had never done this before. We then loosed a few screws at a time starting with the outside door corner and worked our way around, replacing the seal as we took off the old seal. Leaving the old seal on as we worked our way around gave us the clearance we needed to insert the new gasket behind the metal plate which holds the gasket to the door. Your easy to use web site made ordering easy and delivery was unbelievably fast. Thanks.
23 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerrel from REDDING, CA
Parts Used:
WPW10614158
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set, Wrench (Adjustable)
Cracked Evaporation tray was leaking water on kitchen floor
I emptied refrigerator contents and tilted the refrigerator to the right so as to access the metal panel upon which the evaporation tray was resting. The metal panel is on the left side underneath the refrigerator and the evaporation tray is resting on the panel. I removed 4 screws that were holding the metal panel, pressed down on the panel, slid out the old, cracked plastic evaporation tray, inserted the new plastic evaporation tray, raised the metal panel to its original position, replaced the 4 screws, being careful not to pinched the water line that feeds the ice-maker. VOILA! Un-tilt the frig and re-stock it. It took a day for the temperature to stabilize, due to tilting, I think. New tray $45.
24 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Colorado Springs, CO
Parts Used:
WP4388152
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Plastic Water Spout Broke Off
Turn off water supply line fridge. Removing front panel is a must to allow acces to spout and water line. Be careful not to crack front panel $90, it snaps in from the botton, slide a stiff putty knife along bottom edge and gently pry outward to remove. Remove 2 screws that hold spout in place, then cut water line right behind spout. The tricky part is fishing water line down through door. You need to splice new line to old with double sided screw or something with threads that will prevent the lines from pulling apart, then pull water line from bottom of door by hinge, very tight when pulling through hinge opening. You will need to remove vented dust cover at botton of doors to acces the water line. The line has a threaded coupling so unscrew and drain water then cut new line to length. There is a small metal insert in old line that needs to be removed and inserted into new line before attaching coupler. I could perform this in half the time now that I have done it once.
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Hague, ND
Parts Used:
WPW10169511
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice dispensor motor would run but would not dispense ice at the door!
To get the coupler off the motor shaft I took two adjustable wrenches and slit the old coupler where it was cracked.The threads on the motor shaft were stripped closest to the motor.I took two thin washers and put them on the motor shaft so the new coupler would not turn down to where the threads on the motor were sripped.Since the threads on the coupler are left hand they keep the coupler tight as the motor turns the dispenser auger to dispense the ice.I was a bit difficult to unplug the wiring harness but got it after we used a screwdriver to keep the tab bent down until the harness was unplugged.
22 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Evan from Grand Rapids, MI
Parts Used:
4388736
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
The auger drum had broken, not allowing any ice cubes to be crushed or dispenses through the door.
Initially I removed the cover to the auger and auger drum. Then the split ring locking washer had to be removed. I used a needle-nosed pliers and small screw-driver to pry that off. The auger arm could then be removed, and the auger blades removed. This proved to be the part that required the most patience. The blades need to removed and returned in their exact pattern. Someone else suggested taking a digital picture of them before removing them; this is a good suggestion that I failed to do. Once the blades are returned, all the other parts can be replaced in reverse order. Put the screws back in, and you are finished.
22 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allan from Allen, TX
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
refrigerator would not stay cold
The wife found if we tapped the knob for the cold control the appliance would turn on. Upon further inspection I found what looked to be carbon particles under the part. I found the part easily with partselect.com, ordered it, installed it and its like we have a new appliance.
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Martinsburg, WV
Parts Used:
WP2256126
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
The old resevoir needed to be replaced
The repair was incredibly easy -
1. Turn off the water at the water line for the fridge
2. Disconnect the pressure fittings for both lines running to the resevoir.
3. Remove the old resevoir
4. Install the new resevoir and run the lines back to the orginal fittings.
5. Reconnect the fittings, turn on water.
6. Drink water!
35 of 68 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!