Customer:
Vincent from CHICAGO, IL
Parts Used:
WPA3073101
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light over range burned out
Philips screwdriver
Removed screw (1)
Removed light bulb
Put in new light bulb
Closed door to bulb compartment
Returned screw.

Pro tip! Check how many bulbs you need before ordering. Mine only needed two. I got two. I suspect I’ll buy a new microwave before new bulb burns out again. Ordering/delivery was fast. No need to have spare on hand.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Hornsby, TN
Parts Used:
8201515
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
ice maker quit working
I was amazed when Fed Ex pulled up to our front door the following day after I ordered the parts, I was wondering what they were delivering and to my amazement it was the parts I had ordered from parts select the previous day , thank you so much , you are awesome. My 73 year old husband who is a 5 year cancer survivor had the part installed and we were ready to start making ice within 1 hour.He went by the installation information sent in by your customers. Thank you all, Jo Mesplay
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from DE KALB, MS
Parts Used:
WPW10251076
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Ice maker Quit working
Got new part. Removed cover. Tape at top had to be pried loose from door.

Had to turn cup cover from top portion to access power wire. Door and light wires had to be unplugged and moved from clips.

Two screws at bottom removed. Motor unit was freed up and set on table.

Had to remove bottom white section due to light Assembly was not on new section. Removed three screws. Removed three screws from new unit.

Attached old white section with light to new motor unit.

Reattached power wire routed into cup and plugged in. Cup turned clockwise so as to attach.Other wires re-routed and plugged back in.

Cover section screws inserted and reattached.

Turned on/off button back on. Checked all light switches in refrigerator and freezer section to ensure operating. Put bin back in and closed door. No warning lights present. Approximately one hour later, bin had ice in it.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from MARYLAND HTS, MO
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
freezer (later fridge too) wouldn't stay cold~
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Glendora, CA
Parts Used:
8201515
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Icemaker failed to function
Removed and disconnected the icemaker, cleaned all areas and disassembled the failed parts. Reassembled with the new parts inlcuded with the purchased package and resinstalled the unit. Started the unit and chedked for proper operation. Successful repair.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Garrett from RANDALLSTOWN, MD
Parts Used:
WPW10251076
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The ice maker assembly went bad.
I use a Screw drive a Nutdriver set Needlenose Pliers and it took 30mins to fix.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
allen from LANCASTER, CA
Parts Used:
WPW10225581
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
leaking water in freezer
with vidio
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from HELENDALE, CA
Parts Used:
WPW10662129
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer would not freeze
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thick. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from DUNNELLON, FL
Parts Used:
WP2198628
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Socket set
Ice maker grinder motor was not running.
Remove the ice bucket and check that the auger that turns in the ice bucket is free to turn. Cover the open freezer with cardboard or whatever to retain most of the freezer temperature. Remove the holder that supports the top of the motor shaft. Check the splines on the upper part of the motor shaft and also check the seal under the holder. Open the access the door to the motor, remove wiring connector and unbolt the motor. Check the lower splines on motor shaft for condition, clean the shaft and apply new grease to the splines. Before installing, connect the wiring to the new motor, push the door switch in, press the ice dispenser arm outside the door to make sure the motor runs. If all ok, check the motor shaft for fit in the new motor. Be careful not to install the motor shaft too deep in the motor splines, otherwise there may not be enough spline showing on the top end to engage the auger. Bolt the motor in place, close access door and install the holder and ice bucket and make sure everything works. If there is not enough spline showing thru the holder to engage the auger, take pliers and pull the shaft up a bit. This seems to be a hit or miss fit on the shaft but you can adjust the height of the shaft without taking every thing apart again. That's all, not difficult at all. But do check parts and pieces for anything else you might need, parts wise, before ordering the motor by itself like I did. Shipping is high, so try to order any associated parts needed when you order the motor. By the way, This site are great to work with!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joshua from GOFFSTOWN, NH
Parts Used:
4389144
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Upper halves of Refridgerator and Freezer were too warm.
Unplug fridge, remove shelves, remove back cover, unplug old motor, remove adapters from old motor, put adapters on new motor, install new motor, replace cover, replace shelves, plug fridge back in, give it 24 hours to stabilize thermally.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Les from Pine Beach, NJ
Parts Used:
4389144
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Noisey Evaporator Fan Motor
removed freezer shelves, removed back panel with screw driver. removed wires from fan motor, removed fan motor from mounting bracket, removed fan from motor. installed new motor in mounting bracket, installed fan on new motor,installed wiring on new motor. turned power on to check operation, installed rear panel and shelves. total time for job about a half hour
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Lancaster, CA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from FORD CITY, PA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Freezer occasionally had a temperature alarm.Clicking noise also.
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Port Orchard, WA
Parts Used:
EDR1RXD1
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Changed the filter
Took the old one out and put the new one in
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jacqueline from LEXINGTON PK, MD
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
No cold
Like you video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!