Catastrophic loss of cooling
It was straight forward enough--removed six screws from the metal cooling coil shield at the back of the freezer compartment and removed the shield. That left the motor and its mounting exposed atop the coil. Removed the electrical leads and popped out the motor and fan. Then I replaced the leads on the new motor, reset it in the mounting and pushed the fan propeller from the old motor on the spindle of the new. Twenty minutes tops.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Victoria from Alpharetta, GA
- Parts Used:
- WP2220457
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Broken Ice Bin Coupling
While trying to get my icemaker to unjam (ice all stuck together) I broke the coupling under the ice bin. Shouldn't have tried to force it, but you learn from experience...
I found the diagram of what I needed to order on the website and ordered the part, which arrived in about 2 days. Dumped the ice out of the bin, removed the screw that held in the broken coupling, replaced the coupling and replaced the screw. Put the ice bin back into the freezer door and Voila.. ice dispenser works again.
I found the diagram of what I needed to order on the website and ordered the part, which arrived in about 2 days. Dumped the ice out of the bin, removed the screw that held in the broken coupling, replaced the coupling and replaced the screw. Put the ice bin back into the freezer door and Voila.. ice dispenser works again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from LAKE OSWEGO, OR
- Parts Used:
- WPW10238100
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench (Adjustable)
water was leaking from the back of the frig. Issue was the unit that the feed hose screwed into was leaking.
At first ordered the wrong part. Using the website was difficult to find the correct part, but once I called, it was pretty easy to find the part needed. Part showed up and install was only a few minutes. No more leaking!
Thanks for the help PartSelect!
Thanks for the help PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from OVIEDO, FL
- Parts Used:
- WPW10282880, W11164152, WPW10257246, W11746089
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Ordered new crisper pin for refrigerator
After finally getting the wright parts sent to me I took out old bin added the parts to the new bin slid it in and I’m done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Leonard, TX
- Parts Used:
- 4389144
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench set
fan was out of balance and rattleing-vibrating
I pulled the wiring harness off the bad motor, removed the fan blades (it was just a press fit and can be pulled off by hand), took out the three screws. The fan on the replacement motor had to be installed out of the fridge. I wiggled the new motor into place and installed the three screws. I cut the wiring harness off the fridge side and cut back the insulation. Using wire nuts I reconnected the wiring. I plugged the fridge back in and it worked like a champ.
The repair went fairly easy. The motor was a bit difficult to get into tight space with my big hands. The wiring harness on the fridge side had to be cut and wire nuts used to reconnect the wiring to the new motor but it was pretty straight forward. Over all the repair was easy except for being in a tight spot. I recommend trying to fix it yourself, you may supprise yourself and save some serious bucks on labor cost to boot.
The repair went fairly easy. The motor was a bit difficult to get into tight space with my big hands. The wiring harness on the fridge side had to be cut and wire nuts used to reconnect the wiring to the new motor but it was pretty straight forward. Over all the repair was easy except for being in a tight spot. I recommend trying to fix it yourself, you may supprise yourself and save some serious bucks on labor cost to boot.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeanne from COSTA MESA, CA
- Parts Used:
- EDR1RXD1
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Replace water filter
Open door and from appliance instruction book
Replace filter
Replace filter
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Lexington, KY
- Parts Used:
- 8201515
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
The icemaker would not produce ice because the motor that pushed the cubes out had failed. The original icemaker failed in this way and we had the icemaker replaced by Sears Service for about $200. The second icemaker failed for the same reason after 18 months. I decided to do the repair myself t
Open the refirigerator door and push and hold the On/Off button at the top to turn off internal power. Open the freezer door and move the icemaker switch on the right side freezer wall to "off".
To get access to the icemaker, first remove a hinged plastic door that mounts to the ceiling of the freezer compartment by two hex screws. Remove the screws and the door so you can work with the icemaker without interference.
The icemaker assembly will slide out once the wireharness has been disconnected. To disconnet the wire harness, a while plastic shield has to be removed from the right side of the icemaker, just behind the water inlet.
Locate a hex screw on the bottom right rear of the icemaker and remove it with a socket wrench. Then the plastic cover can be pulled off.
Slide the icemaker out enough so you can get your fingers on the plug connector. It takes some effort to pull the plug connectors apart. Once unplugged the whole icemaker assembly can be removed.
The motor module is located on the left side and is protected by a white cover. This cover is not attached so it can be pulled off to reveal the motor module.
Remove 3 screws from the outside of the motor module and the module can be pulled out of the housing. Insert the new motor module. The module turns the shaft of the ice srapper arm. the shaft has a D shape which mates with the hole in the motor module so you may have to roatate the scrapper arm until the shaft shape matches up with the hole shape in the motor module.
Once the motor module is seated, replace the 3 screws and push the white cover back on.
Position the icemaker so you can reconnect the wireharness plug connectors. Once connected you can push the icemaker asembly back into the grooves of shelf rail. Reattach the while protector shield which covers up the wire harness plugs.
Open the refirigerator door and push and hold the power button to turn internal power back on. Move the icemaker switch on the right wall of the freezer to the "on" position and close the door.
The icemaker should start making ice within 2 hours.
To get access to the icemaker, first remove a hinged plastic door that mounts to the ceiling of the freezer compartment by two hex screws. Remove the screws and the door so you can work with the icemaker without interference.
The icemaker assembly will slide out once the wireharness has been disconnected. To disconnet the wire harness, a while plastic shield has to be removed from the right side of the icemaker, just behind the water inlet.
Locate a hex screw on the bottom right rear of the icemaker and remove it with a socket wrench. Then the plastic cover can be pulled off.
Slide the icemaker out enough so you can get your fingers on the plug connector. It takes some effort to pull the plug connectors apart. Once unplugged the whole icemaker assembly can be removed.
The motor module is located on the left side and is protected by a white cover. This cover is not attached so it can be pulled off to reveal the motor module.
Remove 3 screws from the outside of the motor module and the module can be pulled out of the housing. Insert the new motor module. The module turns the shaft of the ice srapper arm. the shaft has a D shape which mates with the hole in the motor module so you may have to roatate the scrapper arm until the shaft shape matches up with the hole shape in the motor module.
Once the motor module is seated, replace the 3 screws and push the white cover back on.
Position the icemaker so you can reconnect the wireharness plug connectors. Once connected you can push the icemaker asembly back into the grooves of shelf rail. Reattach the while protector shield which covers up the wire harness plugs.
Open the refirigerator door and push and hold the power button to turn internal power back on. Move the icemaker switch on the right wall of the freezer to the "on" position and close the door.
The icemaker should start making ice within 2 hours.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from San Antonio, TX
- Parts Used:
- WP2220457
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the coupling had broken
Emptied the ice holder, then removed the two screws located in the bottom of the ice holder. they were holding the metal cover in place, once removed I was able to remove the entire rotating ice prongs which moved the ice into the chute. I had to do this because the screw that held the coupling on could not be removed (too tight) Once the entire rotating device was removed I could easily remove the screw and replace the entire assembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from HOUSTON, TX
- Parts Used:
- 4387478
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Faulty light socket
Followed the video instructions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Adrian from REXBURG, ID
- Parts Used:
- 4389144
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Evaporator Fan Motor quit working; top shelves of freezer got too warm
After viewing online videos of the repair process, it was very easy to replace the evaporator fan motor - just remove the back panel of the freezer compartment for EASY access to the evaporator motor. I received the new motor a day earlier than I thought I would. I took 15 to 20 minutes to replace the old motor. The only problem was the wiring on the new motor was on the opposite side of the motor as compared with the old motor. I was able to rotate the new motor enough for the new wiring to connect. VERY HAPPY with the results. A word of caution: the motor mounting brackets are plastic - go easy when trying to remove the brackets.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Glen from BRENTWOOD, CA
- Parts Used:
- WP2220457
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Coupling broke apart from age
Unscrewed Phillips screw from bottoms of ice container where the piece broke and installed new piece with old washers in place. Placed Phillips screw back in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Janet from PITTSFORD, NY
- Parts Used:
- WPA3073101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
No problem
I had a son put in the new light bulbs. Rather simple
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Suzanne from STERLING HTS, MI
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Refrigerator light would not turn on.
I first replaced the switch and had no results, I then ordered the Light Socket Kit, and because I had the experience of removing the panel to replace the switch, it took a few minutes to remove the two screws behind the panel, removing the temperature control knobs and then releasing the face plate which is secured by tabs at the bottom. The kit came with extra connectors in case they were needed, but they were not in my case and so I pulled off the wires, pushed the old socket out and the new one in. Attaching the wires to the correct pins, I screwed in the light bulb to be sure that the fix was correct and determining that, I replaced the screws that held the panel in place. Voila, I'm a happy camper who found some outdated jars in the back corners of the newly lighted shelves.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from DE KALB, MS
- Parts Used:
- WPW10251076
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice maker Quit working
Got new part. Removed cover. Tape at top had to be pried loose from door.
Had to turn cup cover from top portion to access power wire. Door and light wires had to be unplugged and moved from clips.
Two screws at bottom removed. Motor unit was freed up and set on table.
Had to remove bottom white section due to light Assembly was not on new section. Removed three screws. Removed three screws from new unit.
Attached old white section with light to new motor unit.
Reattached power wire routed into cup and plugged in. Cup turned clockwise so as to attach.Other wires re-routed and plugged back in.
Cover section screws inserted and reattached.
Turned on/off button back on. Checked all light switches in refrigerator and freezer section to ensure operating. Put bin back in and closed door. No warning lights present. Approximately one hour later, bin had ice in it.
Had to turn cup cover from top portion to access power wire. Door and light wires had to be unplugged and moved from clips.
Two screws at bottom removed. Motor unit was freed up and set on table.
Had to remove bottom white section due to light Assembly was not on new section. Removed three screws. Removed three screws from new unit.
Attached old white section with light to new motor unit.
Reattached power wire routed into cup and plugged in. Cup turned clockwise so as to attach.Other wires re-routed and plugged back in.
Cover section screws inserted and reattached.
Turned on/off button back on. Checked all light switches in refrigerator and freezer section to ensure operating. Put bin back in and closed door. No warning lights present. Approximately one hour later, bin had ice in it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- edgar from PAWTUCKET, RI
- Parts Used:
- WPW10225581
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
refrigerator not freeze
i didn't repair replace capacitor, bi metal defrost thermostat and still not freeze also replace light door switch any suggestion thanks