Models > BRS80ARANA00 > Instructions

BRS80ARANA00 Whirlpool Refrigerator - Instructions

Jump to:

All Instructions for the BRS80ARANA00
61 - 75 of 260
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Robert from GOSHEN, IN
Parts Used:
W10156818
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Wife used vacuum cleaner and busted blade off fan
Instructions were great five minutes to remove and replace fan....Thank You............ saved big money
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from North Logan, UT
Parts Used:
4389144
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Bearings were going out
The refrigerator would make loud sounds humming sounds periodically. The bearings were going out on the evaporator motor. Emptied the freezer side of fridge. Unplugged unit. Took shroud off (6 screws). Removed the three wire clips. Pulled fan off shaft. Carefully pushed plastic strap to remove motor. Replaced with new motor. Carefully attached strap to hold motor. This seems very fragile so be very carefull to attach properly and not break. Reverse the rest and done in less than 15 minutes. 30 minutes cleaning the fridge.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gene from COTTONDALE, FL
Parts Used:
EDR1RXD1
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
old filter was overdue for replacement
ordered new filter, removed old filter from fridge, and installed new one
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Orlando from Bayonne, NJ
Parts Used:
WP2300868
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Old one leaks on one side
Simply cut the water tube on both sides of connector and push in the new one.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Evelyne from LOS ANGELES, CA
Parts Used:
W10355588
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refridge door Gasket needed replacememt
Unfortunately the replacement part did not work. The directions required that the older Gasket had to be removed before the new could be inserted. The original gasket was inserted into a groove on the door and also "glued" in some way to the door.

When an area on the side of the door was carefully pulled out it revealed that the new one was insufficient to replace the original.. It was substantially thinner and did not have the design that extended and went into the groove on the door. It needed to go in the slot of the same size and width. There was no such part and no way the new gasket would/could attach to the door.. There was no way to attach this new part. This meant that it wouldn't fit and successfully close the door.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from EUGENE, OR
Parts Used:
WPW10662129, WPW10197428
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
intermittent clicking noise; otherwise fridge seemed to be working fine
Googled "intermittent clicking noise" or something similar and consensus was it was either the capacitor or compressor start relay. You-tubed videos on how to replace these. Looked easy. Just unplug them from the condenser and replace. Contacted Part Select and staff said 50% of the the time it was the capacitor, 50% of the time it was the relay. I was in a time crunch so I ordered both and they came in a couple of days. I replaced the capacitor but the clicking noise continued. I replaced the relay and problem solved! Maybe I could have gotten away with just replacing the relay, but I had them both by then and figured with a 10 year old fridge, better replace them both at the same time and be done with the problem. So far, so good.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from WEST JORDAN, UT
Parts Used:
WPW10238100
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Valve leaking water
Unhooked water line from house to fridge then unbolted valve from fridge body then removed plastic water line from fridge to valve by pushing in on pex release tab then reversed process with new valve. Works like a charm. No more leakage. Wood floor is dry and Happy!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from MESQUITE, NV
Parts Used:
EDR1RXD1
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
ice container bin cracked and had a hole in it.
Took it out of the box. Emptied the ice out of the broken bin. Slid the new one in and all done.
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frederick from APEX, NC
Parts Used:
WP2176759, 4389144
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Noisy operation (from the inside)
Unplug, then on the freezer side, remove the drawers, then remove the screws holding the sheet metal cover, remove the rails (for the drawer) that interfere with removing the sheet metal cover. pull the wires off the motor. There is a big plastic piece that holds a small plastic piece that holds the motor. Remove the plastic piece that holds the motor/fan (you might be able to swap the motor by removing the little plastic piece that holds the motor, or you can remove the bigger piece and then remove the small piece that holds the motor). Pull the fan blade off (to reuse), swap the motor. NOTE - the new motor wire terminals may be on the opposite side of the motor vs. the old motor - that is not a problem - there is plenty of room for the wires. After the motor is installed put the fan blade back on, reinstall the removed plastic pieces in the back of the refrigerator. Now, I'd suggest a quick test. Make sure the new motor works and the fan blows before you button it up. Once you know it works, power it off, and put the sheet metal cover back on, reinstall the basket brackets, put the baskets back in place, close the door, and turn it back on.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from COALINGA, CA
Parts Used:
WPW10662129, WPW10197428
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrigerator freezer stopped cooling
Prior to ordering I removed freezer panel and checked for ice build up and fan functionality. Then removed rear panel cleaned lint from everything pulled front panel vacuumed out the condenser. Plugged back in and all seems to work with the exception of compressor. I have a little experience so googled in model number and your site popped up. I looked up part and the site gave me a percentage loved that. I ordered wish I would have rushed shipping as took about 10 days. Installed in less than 30 minutes and all runs great ??
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Martin from Palm Coast, FL
Parts Used:
8201515
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ice Maker stopped making ice.
Unplug power to refridg/freezer. Removed the screw in rt. rear bottom of ice maker to remove. After removing slightly, unplug pigtail. Remove ice maker completely. Remove large square cover from left side to expose motor. Remove screws to remove motor. Replce with new. Replace ice maker to freezer, plug pigtail back in, put screw back in rt rear bottom, plug refridg/freezer back into power source. Ice was making in about 2 1/2 hours.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from SAN DIEGO, CA
Parts Used:
WPW10662129, WPW10197428
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Random clicking noise
The toughest part was pulling the refrigerator from the wall....After removing the back-bottom access panel the compressor is right there with the Start-Dev and Cap..Took a few min to remove and install new parts....Very Simple and works great...no more clicking..
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from LASCASSAS, TN
Parts Used:
WPW10238100
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Wrench (Adjustable)
Leaking around icemaker hose going in to part
Took lower back board off, took part off to expose it so I could see where it was leaking, got part number, ordered it.
Shut off water to frig at wall shut off, unhooked both hoses and plug, hooked new part up, turned water back on. Watched couple days to make sure it wasn't leaking. Vacuumed out back good, which I was amazed didn't really need it, hooked part back in place, replaced back with screws.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the BRS80ARANA00