Customer:
timothy from indio, CA
Parts Used:
WPW10190929
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Mold Ice Heating Element Broken
Looking at the ice maker it is pretty cut & dried as to how to remove the unit. I took out the ice tray and just started removing all the mounting screws. The same for the mold ice tray & heating element. I was just sad that you did not have just the heating element separate from the mold ice tray.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LARRY from DYER, TN
Parts Used:
4318046, WP2196157
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Wrench set
ice maker leaking or overflowing into ice bend
first bought new ice maker installed it-didn`t fix the problem. next bought fill tube kit and dual outlet vale -installed those ice maker works GREAT no leaks -no ice froze together in bend. thanks for the help GUYS.
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Melvin from OPELIKA, AL
Parts Used:
W10823511
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
35 year old water tube became brittle and cracked; leaking water
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Harahan, LA
Parts Used:
WP4388152
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
water nozzle was cracked and leaked
I removed the screw holding the nozzle in place, and removed the other end of the line under the refrigerator to give me some slack. Then I clipped the nozzle off of the black line and taped the new line to the end I cut off with electrical tape. Then I just snaked it down through the hole with me pulling from the bottom and my wife pushing from the top and reattached both ends. Make sure you don't use too much tape becaue it won't fit throught the hole at the bottom. I taped them together at an angle so not to make tape too thick. Also, you can snake it back from the bottom if the tape breaks and the old line comes out of the fridge.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
anthony from georgetown, IL
Parts Used:
WP628356
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Broken Piece
Had to disassemble ice maker to install part. . .
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hal from Virginia Beach, VA
Parts Used:
4318046
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench (Adjustable)
Icemaker not working
Started the replacement of the existing dual outlet valve by removing cardboard covering the lower back of the refrigerator exposing the outlet valve. Closed the water supply valve at the wall. Removed the hose bibb water supply connection on the outlet valve by hand as it is only hand-tight. I used a small plastic container to catch the minimal amount of water left in the copper line. I removed the electrical connection on each solenoid valve (one for the in-door water supply and one for the icemaker supply). I removed the plastic supply lines from the outlet valve. I removed the screws on the bracket attaching the dual outlet valve to the refrigerator vertical rail. I reconnected the electrical connectors to the valve. I reattached the plastic supply lines to the valve, but did not tighten them fully at this point. I secured the bracket on the new valve to the existing screwholes on the refrigerator rail. The new outlet valve does not have a hose bibb connector, it has a compression fitting for the supply. I reused the existing copper supply line from the wall angle-stop valve to reconnect to the new outlet valve. (It would have been best to have cut the copper line and used a new furrel on the copper line). Note that the supply line now comes into the outlet valve from the top, not the rear as on the old valve, so now the dual outlet valve sticks out beyond the frame of the refrigerator. I tightened the nuts on the plastic supply lines on the valve. I had to cut the cardboard cover around the new outlet valve. Resecured the cardboard cover to the back of the frig. Checked for leaks, turned the icemaker on by lowering the shutoff arm, and after a few moments, the outlet valve opened, water flowed into the icemaker, and all is well.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from WAUPACA, WI
Parts Used:
482469, 2188404A
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Chirping sound coming from the freezer-old gasket on food door causing air leakage r
Removed shelving,ice maker & other air deverters to get at fan motor. Disconnected power, then removed motor by removing screws holding motor assembly in place. Push fan blade on to motor reconnect wiring.
Chirping stopped and ice cream is now rock hard.

Food door gasket was more time consuming than hard. Loosen old gasket screws with not driver. Gasket is then easily removed. Reinstall gasket, but keep retaining strips loose so you can adjust gasket for a correct fit.
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Troy from Kansas, OK
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Freezer wouldn't defrost/low temps in refrigerator
Found the housing for the thermostat; took housing apart pulled out thermostat and took off the hose put the hose on the new thermostat installed new thermostat and replaced housing.
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sheila from Lena, MS
Parts Used:
4388736
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker would no longer move ice through the dispenser
As cookbook authors and publishers, my husband and I depend on our appliances. When our icemaker would no longer work, it was imperative that we repair it as quickly and ecomonically as possible. We had used PartSelect.com earlier to order a part to repair our Jenn-Air stove top and had great results. So, rather than paying a repairman four times or more the cost of the part, we ordered the part and my husband installed it. It took less than 30 minutes to remove the broken auger and install the new one. THANKS PartSelect.com -- we'll use you for all appliance parts needs.
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gregory from Milford, OH
Parts Used:
W11342242
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice maker was over producing
Technician at ASK suggested replacing ice maker. Ordered new ice maker(prompt delevery)then noticed it came without wire arm and white platic "flag". Ordered arm and "flag", replaced all old with new and seems to be doing well. Perhaps all I needed was the plastic "flag" on the limit arm wire. Will never know. The new icemaker wiring had short wires and a connector. Old ice maker had no connector so the short wires were removed and the old wires plugged into the ice maker. Mirror was required in order to see the side wall mounting screws. Very narrow work area, tiny freezer side.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Billings, MT
Parts Used:
WPW10190929
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Black flecks in ice
The lining of the ice mold (Whirlpool) started flecking off (black flecks in the ice cubes), so I decided to replace the mold.
Loosen the two 1/4 inch upper nuts and remove the lower nut to remove the ice maker from the freezer. The hardest part was getting it unplugged. I used a small blade screwdriver to release the catch on the connector and pull it out.
Remove the ice maker front cover. If you have a skinny enough phillips screw driver, there are two deep set screws through two holes on the lower portion of the control module (otherwise, remove the three screws on the controller, unlatch the shut-off arm from the control module, and separate the controller to access the mold screws). Unhook the shut-off wire from the end of the tray. Unscrew the two screws holding the mold and remove the mold.
Remove the plastic hardware from the old mold and install on the new mold.
Attach the new mold on to the control module.
WARNING WARNING WARNING!!! The mold I bought already had the alumilastic on it for the contact point to the thermostat. When I installed it and tightened the screws, the alumilastic was dried out, didn't squash down, and dented the bi-metal thermostat on the controller, ruining it. I had to buy a new thermostat. Be sure to check that the alumilastic is pliable. If not, take it off and buy some fresh to put on there.
Re-install the ice maker. It took a while to get the first batch of ice because the ice maker was at room temperature and I had the freezer door open for several minutes. So the freezer had to get cold and the ice maker had to chill down. Once everything got cold, it started making ice again.
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Indianapolis, IN
Parts Used:
WP2187464
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
no power to the ice maker
The wiring harness was a straightfoward plug in replacement after depressing the securing tabs, and did provide power to the icemaker. However, the icemaker would continually cycle, with the mold heater on at all times. I suspect this is what caused the thermal fuse to blow in the first place. Rather than spend more time replacing individual components, I eneded up replacing the full ice maker assy. The new ice maker works properly.
11 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
roberto from san Antonio, TX
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
freezer gets too cold then gets to regular tempetured
disconect the power removed the screws with the phillips screwdriver removed the front cover and then removed the rest of the screws. removed the three covers and then removed the thermostat. replaced in reverse order.
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
NANCY from KEOKUK, IA
Parts Used:
W10749708, 4388736
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Icemaker Wouldn't Work
I removed the screws that attached the drum housing to the bin. I detached the auger & removed the broken drum assembly, turning the auger to the right, opposite what I thought it should be. I slipped the end of the auger into the new bin coupler & put it in place at the rear of the bin. Next I slipped the auger drum into place & tightened it to the left with a socket wrench. I screwed the drum housing to the bin, put the bin back into the freezer & I now have ice through the door again. Easy repair even for me, a 60+ woman.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Lewisville, TX
Parts Used:
WPW10329686
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Socket set
Refrig Door Cams wore out and made noises when opening and closing.
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two year old Frig. This is a design problem, as the cams should last longer than 22 months.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ED22DWXTW00