- Customer:
- HARRY from FSTRVL TRVOSE, PA
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Freezer drawer light switch failure.
Disconnect plug from wall. Insert putty knife between light switch.and trim panel , apply pressure to depress plastic spring holding switch in place. Apply a slight twist too putty knife releasing switch from trim piece. This wil expose plug connected to switch. Disconnect plug from switch. Connect new switch to plug. Insert switch into trim. Plug refrigerator into wall socket.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from MT PLEASANT, SC
- Parts Used:
- WPW10503278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fridge running warm
The fridge would occasionally run warm, requiring me to turn it off and defrost the evap coils in the freezer. I found an online video that demonstrated the entire process of replacing the control board. The fridge model in the video was different than mine, so it took some time to figure out how to remove the panel. Once that was done, the rest was easy. The only tool required was a flat-head screwdriver that was used to push in the tabs holding the panel in place. The circuit board took more effort to split in two than I had realized, and I had to be careful not to bend any of the components on its surface. The whole process took less than 30 minutes, and the fridge is working properly now..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from LAGUNA HILLS, CA
- Parts Used:
- W10884390
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Ice Maker Not operationl
Have part need instructions to remove old and install new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from MABLETON, GA
- Parts Used:
- W10619951
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Easy fix for Whirlpool refrigerator
I followed the video provided by Part Select. I also let the refrigerator stay unplugged overnight with all the doors open. This p-trap kit has fixed the leaks out of the front of the refrigerator. There is no ice build-up in the freezer. Perfect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paul from HARWICH, MA
- Parts Used:
- WPW10498976
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
not dispenceing water
replaced water valve still does not work
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nancy from LOUDON, TN
- Parts Used:
- WP67006877
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
broken glass shelf
Replaced shelf, very simple
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from KEWANNA, IN
- Parts Used:
- W10884390
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Dripping ice maker
Replaced ice maker, but new one drips.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from GOLDEN, CO
- Parts Used:
- WPW10503278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
About twicw per year the freezer would ice up because the control board didn't activate the defrost element
Removed the cover using a mirror to see how to release the clips on the rear side of the cover, removed the circuit board noting how everything was installed and also visually verified the part was the same. Broke the circuit at the designated score, installed and followed instructions for programming. All is well now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from ONEONTA, NY
- Parts Used:
- W10884390
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Replaced Ice Maker in Bottom Freezer
Looked at several videos on line in order to learn how to remove door and and all trays and bins and remove ice maker. Mostly straight forward. It helps to have a second pair of hands and eyes to assist. But could be done alone.Never did this before but I would say that, with a little courage, anyone could do this. I had a local repair estimate of almost $300. I did the job for the cost of the part, $80.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from HUNTINGTN BCH, CA
- Parts Used:
- W11396033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Difficulty removing old switch.
Everything went as planned except the cold temperature (freezer door switch located inside freezer) made deflection of the switch locking tab difficult to remove. Letting the switch warm up was not an option.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Bismarck, ND
- Parts Used:
- WPW10655367
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
drip pan was cracked
Removed rear cover, removed fan and than drip tray. install new tray and reassemblied
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Meridian, ID
- Parts Used:
- WPW10503278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Lower freezer section was icing up, not defrosting properly. Repeated manual defrosting including disassembling did not solve the problem.
Emptied and disassembled the freezer. Defrosted and dried the coils. Tested the defrost heater coil ( 50 ohms ) PRT and fan - all OK. Opened the lower back panel and cleaned the water collection tray. Vacuumed out all debris including coils underneath. Reassembled everything. Removed the old control board and installed the new board paying attention to ESD steps. Applied AC power. Programmed the new board per the video link ( nicely done ). 3 weeks later and the unit seems dry and happy. Running at lower settings with good temperature results. Suspect the 24VDC relay activating the defrost heater coil on the control board or what controls the relay not working. May pull relay for test.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Red Banks, MS
- Parts Used:
- 12002497
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Broken Freezer Drawer Gear
Checked Video online. Had to remove the 2 snap on track/gear covers. Pry out the gear with screwdriver and the gear bearing unit. Align the flat side of the bearing unit and snap in. Position the cut teeth on the gear to match original and snap into the bearing. Insert the connecting rod into the long shaft gear and then push back into the short shaft gear. The video said to remove the drawer front but I did not and don't see that it necessary.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from FAIRFIELD, VA
- Parts Used:
- WPW10503278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Unit would not defrost
I checked the element and the thermostat and determined the problem to be the control board. I simply followed the instruction in the video. Everything went well until the last step, the video said to push the freezer down button. When this did not work I refered to the written instructions which told me to push the up button. That did it. Job complete. The unit is working as it should.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- DELP from Hubert, NC
- Parts Used:
- W11024089
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
freezer worked fine, refrigerator would not cool
with the freezer working I knew the compressor was working. I confirmed that the actuator door in the refrigerator was working but no air was blowing out. The hardest part was removing all the freezer drawer components and the ice maker so I could remove the panel in the back covering the evaporator motor. A quick resistance check of the motor confirmed no continuity in the motor. Take your time so that you dont break any of the snap in pieces. The motor I received did not look like the one I was replacing, but in fit in place and bolted right in. They provided an adapter wire to connect the wiring. All in all it was a fairly easy job. The video I followed was very helpful.
Was this instruction helpful to you?