EB22DKXFB01 Whirlpool Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Eugene from Erie, PA
- Parts Used:
- 4386917
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
End caps broke on the lower shelf
Slid the end caps onto the shelf, placed the tape on the pieces as noted in the directions, and put the shelf back in place. Fast service, exact part, easy to find on the web site! Great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Colchester, CT
- Parts Used:
- WP12550116Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Orginal gasket was falling apart
carefully
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- terrie from broomfield, CO
- Parts Used:
- WP10513803
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
making noisy
Removed screws to pull the part out and took fan off. Put fan back on the new part and put it back in place. Runs very quiet !!!
Thanks !
Thanks !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Granada Hills, CA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Greensboro, NC
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- craig from maple grove, MN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Luigi from Alexandria, VA
- Parts Used:
- WP12550116Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
The old seal was torn and did not fully close leaving a gap.
I simply used my cordless drill with the right sized socket attachment to remove the screws. I left the door on which wasn't as difficult as I thought after reading other stories. I even had to contend with my three year old who wanted to know what was going on and if she could help. As my wife is deployed it falls to me to become both parents, watch after her and take care of chores. With all that said it still only took me about half an hour to replace the old gasket with the new one. As far as the gasket goes I wish the magnet was more powerful because there is still a gap unless you push and hold it closed for an extra second when closing the freezer. A pain but at least it is not torn. Before buying I recommend searching for a parts/service center that that talks about the whole part not just how to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Latrobe, PA
- Parts Used:
- WP12550116Q, WP12550115Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Gaskets were not sealing due to wear
I loosened(but did not remove) the 1/4" sheetmetal screws around the perimeter of the door liner. (they are numerous and they are hidden in the fold of the gasket) I removed the old gasket. With the screws still loose, I installed the new gasket. After insallation I re-tightened the liner screws. Several gaps were noted and eliminated by gently heating the gasket with a hair dryer. (be patient , it takes some time)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- carol from woodland, WA
- Parts Used:
- WP12550116Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
The freezer would frost up because the gasket didn't close tightly
First we read all the comments by other handymen. This was really helpful. Then we took the door off and removed the old gasket with a nut driver. We tried to slip the new gasket under the edge with a thin spatula and didn't have much luck. Then we remembered someone saying that is was a good time to take the door apart and check to see if there was ice build up in the door. It was so bad we took out the frozen insulation and replaced it with new....$4.00 at the hardware store. While the door was apart we put the gasket on and put it in place and tightened it to the door. This worked very well for us. This saved us from having to buy a new refrigerator/ freezer. Thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Annandale, NJ
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Frost build up in freezer
1- Remove food from freezer and store in ice chest
2- Turn off refrigerator
3- Remove freezer drawers, 2 drawers, no fastener
4- Remove freezer slide out drawer front , 2 screws
5- Remove ice cube tray holder, 2 screws
6- De-ice back panel with hair dryer / blower
7- Remove back panel in freezer, 8 screws
8- Defrost refrig coil with hair dryer / blower
9- Unplug Bimetal Thermostat, 2 wires, orang / brn
10- Remove Bimetal Thermostat from coil, 1 clip
11- Install new Bimetal Thermostat
12- Re-assemble, reverse order
2- Turn off refrigerator
3- Remove freezer drawers, 2 drawers, no fastener
4- Remove freezer slide out drawer front , 2 screws
5- Remove ice cube tray holder, 2 screws
6- De-ice back panel with hair dryer / blower
7- Remove back panel in freezer, 8 screws
8- Defrost refrig coil with hair dryer / blower
9- Unplug Bimetal Thermostat, 2 wires, orang / brn
10- Remove Bimetal Thermostat from coil, 1 clip
11- Install new Bimetal Thermostat
12- Re-assemble, reverse order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Nashua, NH
- Parts Used:
- R0131577, WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
refrigerator section warm 62 degrees, freezer normal
Started with internet searches then began with removal of wall plate at back of freezer, pulled power cord first. Found evaporator coil completely frozen over.Went back to internet and searched possible causes. It seemed to me that the auto defrost system may not be functioning properly so I considered possible causes. Defrost thermostat, defrost timer, or possibility heater itself. I chose to go with simple stuff first and thought heater would have a better relibility characteristic. Went to Parts select got part numbers and was able to find part locations on the appliance. So far so good, and knock on wood! Thanks Parts select I spent $50 bucks instead of $1000.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Williamsburg, VA
- Parts Used:
- WP12550116Q
- Difficulty Level:
- Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer Door Gasket needed replaced.
There were no instructions with the new gasket which made the job difficult. After great difficulty I called an appliance store and learned that the gasket should be soaked for several minutes in very hot water to make it pliable and easier to install. Also, the plastic insert that the gasket fits into should only be loosened and not removed when inserting the gasket. Lastly, the door should be removed and placed on a table to allow leverage to be applied. Installing it while still on the door is almost impossible.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Graettinger, IA
- Parts Used:
- W10833899
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Socket set
icemake stop working
replaced water valve and new icemaker.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Lowell, MI
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from LAURENS, SC
- Parts Used:
- W10833899
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench set
Faulty water-intake valve
Water Intake valve for icemaker in Amana refrigerator
We found that the icemaker was not getting water due to a faulty intake valve. The original valve had a plastic coupling on the vinyl tube leaving the valve. The replacement valve had a quick connect coupling. Replacing the valve with the new part gave a significant leak. After discussion and viewing YouTube directions multiple times, the part was returned; and a new part was sent. It also leaked.
After searching, a video was found that dealt with the no-fail quick connect. The problem was not in the quick connect but in the tube from our refrigerator which had a spring inside the last five inches of the tube. This aided the prevention of a leak when the original plastic coupling had been installed.
SOLUTION: Removing the part of the tube with the spring using a clean cut allowed the quick connect to work preventing the leak. This needs to be mentioned in the how-to videos to save others having a problem. Also, these instructions with the part would be helpful.
The longer than usual repair times shown above were the result of the spring insert in the plastic water tube of the refrigerator. Nowhere in the how-to instructions were references made of either an insert in the tube or quick connect procedures.
We were well pleased with the support rendered by the PartSelect staff.
We found that the icemaker was not getting water due to a faulty intake valve. The original valve had a plastic coupling on the vinyl tube leaving the valve. The replacement valve had a quick connect coupling. Replacing the valve with the new part gave a significant leak. After discussion and viewing YouTube directions multiple times, the part was returned; and a new part was sent. It also leaked.
After searching, a video was found that dealt with the no-fail quick connect. The problem was not in the quick connect but in the tube from our refrigerator which had a spring inside the last five inches of the tube. This aided the prevention of a leak when the original plastic coupling had been installed.
SOLUTION: Removing the part of the tube with the spring using a clean cut allowed the quick connect to work preventing the leak. This needs to be mentioned in the how-to videos to save others having a problem. Also, these instructions with the part would be helpful.
The longer than usual repair times shown above were the result of the spring insert in the plastic water tube of the refrigerator. Nowhere in the how-to instructions were references made of either an insert in the tube or quick connect procedures.
We were well pleased with the support rendered by the PartSelect staff.
Was this instruction helpful to you?
Thank you for voting!