Models > 95-1982-00-01 > Instructions

95-1982-00-01 Tappan Refrigerator - Instructions

Jump to:

All Instructions for the 95-1982-00-01
76 - 90 of 104
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Gerald from Goldsboro, NC
Parts Used:
5303917590
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
Deforst Drain Pan rusted out
The old drain pan had a 1 ½” tall bushing attached to the center of the pan. The new pan did not have this bushing which was great. I had to cut about 1 inch off the bushing to remove the old pan. Also after cutting the bushing I had to screw the bushing off after cutting the old pan from the bushing. I installed new pan onto the ½” of threads that was left on the top of the compressor. Checked repair two days later all was great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronnie from Abbott, TX
Parts Used:
5317842502
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer was freezing up and would run all the time and not cycle off.
Unplug the refrigerator. You will ultimately need to remove the back panel of the freezer. But first, you will need to unscrew 2 screws on a small vertical fan vent and unscrew two screws on the fan. Maneuver the fan out of the round hole in the back panel and unplug the 3 prong wire connection. Then remove the fan. Unscrew the 4 remaining visible screwson the back pannel and remove the panel. This will expose the freon coils. On this model, the heater has two connections at the top of the coils. Unplug those wire connections. The heater extends down each side of the coils and along the bottom of the coils. Unhook two aluminum ties that connect the heater element to the coils. These ties stabilize the heater element and also prevents any current from flowing along the element because of the touching of two different metalic parts. Maneuver the heater element out of the coils. To install the new heater, reverse the above process beginning with installing the new heater element. If it hasn't already been done, it is good idea to test the old heater element with an ohm meter to make sure that the element is actually bad. The circuit should be open. This is the second heater element that I had to replace on this refrigerator, and it was actually burned in half both times, so I knew for sure the element was bad. Then test the new element to make sure it is good, and start the installation..
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from West Columbia, SC
Parts Used:
218730609
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
gasket was torn
removed everything from door, removed screws in gasket around door, laid door face down(insulation side up)applied rtv around edge of gasket and door, waited 10 minutes and started with top screw in middle of top then middle of sides and bottom then installed remaining screws checked levelness of refrigerator, the you are done
Was this instruction helpful to you?
Thank you for voting!
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Rapid City, SD
Parts Used:
218906802, 316538904
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
My Frig Light Stopped
I am a 65 year old woman with no mechanical aptitude: I just unplugged the frig. And used a screw driver to pry of the plastic socket from its outside edge. . Then you just unplug two tiny contact plugs that appear when you pull out the socket and replug in those two the same way on the new part. Pop the socket back into the hole . . . . And screw in the new bulb. I knew I needed the socket part cause when the bulb burned out , a new bulb still did not work. . . If I can do it, anyone can!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Armando from Eagle pass, TX
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
the evaporator fan same time won't stater
change the evaporator fan motor kit working perfect
Was this instruction helpful to you?
Thank you for voting!
Customer:
Guillermo from Miami, FL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
K from Lakeview, MI
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Refrigerator side not cooling (of Side by Side)
Turned off Refrigerator by thermostat switch in Freezer Compartment,(allowing for light to work in freezer). Then removed all food from freezer side,then all shelves & basket drawer. Next, unplugged refrigerator from electrical source. Removed back of inside of the freezer. Located the Thermostat for defrosting cooling coil. Removed and replaced with new part.(Tip-unplugged the wires for the original thermostat, remove from freezer and cut off and splice with connectors provided with new part, it's easier because you're not trying to do this in the narrow space of the freezer). Then attach the thermostat with new bracket and plug thermostat wires back in, replace back panel, shelves, plug in power supply, turn thermostat switch in Freezer to normal setting. Wait for Freezer to cool and replace food. It's currently working like new. BTW I thought I need a defrost time as well...however after I ordered that part and received it, I turned the existing defroster timer manually with a straight ended screwdriver very slowly and it cycled and the defrost rods glowed/functioned just fine. Therefore I didn't replace defrost timer. I'll save the new timer for future repair if needed. All in all it was fairly easy, and I didn't have to buy another fridge. I was really pleased with the service of this website...and the parts arrived very quickly via Fedex. Thanks www.partselect.com ! KJ
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ben from deer park, TX
Parts Used:
5300158289
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Not freezing
All I had to do was change out motors, and the fam would spin right,and the freezer was alive again. With your older models you may have to re-mount the motor bracket in the back for the fan to clear,due to the fact that the motor sits alittle lower than the old model
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from New Ringgold, PA
Parts Used:
5300158289
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Replace evaporator fan motor.
Replace evap fan motor. Take a close-up picture of the evaporator fan motor installation prior to removing. Take pictures as removing various components.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Simon from Boca Raton, FL
Parts Used:
218730609
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Replace Door Gasket
First I removed the inner door which was easy and used a drill with a hex head driver to undo all of the screws behind the gasket. Trying to fit the new gasket on was a fidely nightmare. It's not too bad to get the sides on but the corners are very difficult. At first I had left the door on the fridge after an hours worth of swearing I took the door right off and laid it flat on a table. When I finally got the gasket all on, with a couple od small tears, I hit it with a heat gun and got most but not all of the wrinkels out. When I put the door back on the fridge it wouldn't close properly - gaps in the gasket. I leaned some weights against the door and it the gasket with the heat gun again. Gradually over 2 days it fit fairley well.
Was this instruction helpful to you?
Thank you for voting!
Customer:
THOMAS from ENDWELL, NY
Parts Used:
5300158289
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Wrench set
Refrigerator section of fridge was too warm.
Removed the old burned out evaporator fan, and with the model# was able to find a replacement at PartSelect. I was really surprised that you had the exact part on a fridge that old. Installed the new fan, and the fridge is working beautifully. Thanks to PartSelect I was able to save several hundred dollars.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sam from Marshall, NC
Parts Used:
5303917954
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver
freezer cold, fridge not cold
Removed shelving, and rear panels. Replaced condenser fan and defrost thermostat. Defrost coil ohmed fine. Reassembled and plugged in fridge with thermometers inside. Freezer at 22degrees and fridge at 32 degrees. My first time repairing a fridge. the partselect videos were very helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 95-1982-00-01
76 - 90 of 104