- Customer:
- Richard from Simi Valley, CA
- Parts Used:
- 5300158289
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Noisy Motor
I original tried to repair the motor but was not able to. I remove the screws on the back plate and removed the the back plate. Removed the shroud for the motor and screws, unplug the power connection and removed the fan motor. Installed the new fan motor and reassembled everything. The refrigerator is working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from merrillville, IN
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Heater not coming on - coil frosting up- freezer and Refrig. warm
The instructions given to me by part Select were very good.I replaced the Timer- checked the heater with oham meter it was good- checked the door weather striping it was good and replaced the thermostat with new .So at this point I may need to call a professional unless some one has another solution.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Goldsboro, NC
- Parts Used:
- 5303917590
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
Deforst Drain Pan rusted out
The old drain pan had a 1 ½” tall bushing attached to the center of the pan. The new pan did not have this bushing which was great. I had to cut about 1 inch off the bushing to remove the old pan. Also after cutting the bushing I had to screw the bushing off after cutting the old pan from the bushing. I installed new pan onto the ½” of threads that was left on the top of the compressor. Checked repair two days later all was great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronnie from Abbott, TX
- Parts Used:
- 5317842502
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer was freezing up and would run all the time and not cycle off.
Unplug the refrigerator. You will ultimately need to remove the back panel of the freezer. But first, you will need to unscrew 2 screws on a small vertical fan vent and unscrew two screws on the fan. Maneuver the fan out of the round hole in the back panel and unplug the 3 prong wire connection. Then remove the fan. Unscrew the 4 remaining visible screwson the back pannel and remove the panel. This will expose the freon coils. On this model, the heater has two connections at the top of the coils. Unplug those wire connections. The heater extends down each side of the coils and along the bottom of the coils. Unhook two aluminum ties that connect the heater element to the coils. These ties stabilize the heater element and also prevents any current from flowing along the element because of the touching of two different metalic parts. Maneuver the heater element out of the coils. To install the new heater, reverse the above process beginning with installing the new heater element. If it hasn't already been done, it is good idea to test the old heater element with an ohm meter to make sure that the element is actually bad. The circuit should be open. This is the second heater element that I had to replace on this refrigerator, and it was actually burned in half both times, so I knew for sure the element was bad. Then test the new element to make sure it is good, and start the installation..