Customer:
Stephen from Warrington, PA
Parts Used:
5303917954, 215846602
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Fridge got warm and freezer coils were frosted
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders.

Pulled plug.

Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be removed.

Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.

Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.

Removed old badly corroded thermostat.

I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.

Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.

Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.

Plugged back in and everying is working great!
336 of 400 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jordan from Maumee, OH
Parts Used:
5308000010, 5300158289
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Noisy fan
1. Removed the 7 nuts using the nut driver from the freezer back panel inside the freezer.
2. Remove the back panel. The evaporator motor and fan are located above the coils.
3. Unplug the wiring harness.
4. Remove the two gold mounting screws holding the motor and fan in place.
5. Remove the motor and fan including the brackets.
6. Install the new motor and fan onto the mounting bracket.
6a. Attach the green ground to the mounting bracket.
7. Screw the two gold screws back into the freezer.
8. Attach the new wiring harness. Note, the old harness had a mounting hole/space for it to connect to the wiring harness of the freezer. The new motor's harness was not long enough for this, so it is connected freely to the freezer harness.
9. Use the hair dryer to melt any ice that may have formed on the coils and hole where the fan goes.
10. Turn the freezer on to see if the fan turns on.
11. Reinstall the back panel.
All done!
152 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Melvin from Semmes, AL
Parts Used:
216008900
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Clicking sound then within a minute clicking again, not cooling.
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it rattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
79 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tad from Lancaster, OH
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Side-by-side .. freezer working, fridge not cooling
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
46 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Alexandria, VA
Parts Used:
218906802
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light socket melted around bulb
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
65 of 107 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Emily from Saint Louis, MO
Parts Used:
5308007123, 218730603
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Gasket was old and not sealing correctly
There are quite a few bolts that needed to be loosened to remove the old gasket and put on the new one. We tried to do it by just loosening and leaving the door on the fridge...take my advice. Just remove the door, remove all the bolts, put the new gasket on and replace the bolts then the door. MUCH EASIER than trying to fit it on inch by inch and having it pull back out etc.
45 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Todd from pottstown, PA
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
no cooling in fridge or freezer due to bad defrost timer
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ROY from PENSACOLA, FL
Parts Used:
5308000010, 5300158289
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
The Evaporator Fan Burnt Up
The fan motor all but caught the inside of the freezer on fire . Had to remove then clean, and I mean clean the walls of the freezer . Then had to pry out the old fan without breaking anything . Replacement of new fan was quick and easy because all the parts that I needed were in the bag
28 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Erle from Boise, ID
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
First, unplug the refrigerator since you're working with live wires.

Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.

Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.

Attach the new defrost timer to the plastic housing with the 2 screws.

Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.

Plug the refrigerator back in and you're done.
24 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Cedar Park, TX
Parts Used:
5303305486, 215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The refrigerator portion would range in temperature from 30 degrees to 65 degrees every 24 hours, freezer would sometimes get warm
Removed the temperature control dial,took out the 3 screws that hold the cover for the thermostat and defrost timer, disconnected both the defrost timer and thermostat and replaced with new items. The refrigerator temperature has now been staple for one week.
25 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Giuseppe from brick, NJ
Parts Used:
5304464438, 216008900
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
buttom of refrigerator not cold
unplug it, pulled compressor start relay,which i thing it was the problem, but i replace bolt, very easy.
22 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Todd from Thornton, CO
Parts Used:
5303917954, 215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Fridge warming but freezer still frozen
I ordered a defrost timer and defrost thermostat from partselect.com. Parts arrived in 2 days (earlier than expected). Unplugged appliance, removed bottom cover, unscrewed 2 screws holding timer in place, unplugged timer and replaced with new part. Fastened back into place. Next removed back cover of freezer (5 screws using nut driver). Disconnected old thermostat and removed. Wires already had connectors installed. cut off the connectors with some wire left on and reconnected them to the new thermostat with the included blue wire crimps. Tried to use the shrink tube to insulate but couldn't get it snug enough. Just used electrical tape instead. Reinstalled thermostat. Reassembled cover. Plugged in and fridge and freezer are working fine again. Thanks partselect.com.
22 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Miles from Longview, TX
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator freezing
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
22 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Denise from Lowell, MI
Parts Used:
5304464438
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
just quit working
Bought a new
capacitor.
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Virginia Beach, VA
Parts Used:
5304464438, 216008900
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
would not freeze
unplugged, removed old parts, replaced with new
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?