Models > GTN198WH1-45 > Instructions

GTN198WH1-45 Tappan Refrigerator - Instructions

Jump to:

All Instructions for the GTN198WH1-45
16 - 20 of 20
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Wayne T from Galway, NY
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Freezer was not defrosting thus refrigerator was not cooling
1. Unplug the refrigerator.2. Remove the storage rack and back panel in the freezer. 3. Locate the thermostat. 4. Defrost the freezer coils , i used a hair dryer. 5. Remove the thermostat from the cooling coil and then clip the connecting wires close to the unit. 6. Strip the ends of these wires and connect these wires to the wires of the replacement unit using the supplied wire connectors. 6. Heat seal with a lighter the connections using the water shield sleeves provided and further wrap connections with electrical tape. 7. Reconnect the thermostat to the cooling coil at the location it was removed from. 8. Replace the freezer back panel removed earlierand the storage rack if you have one. 9. Plug the freezer back in. My refrigerator has been working ever since the repair. There are several YouTube videos available that walk you through the diagnoses and repair process. They are very good.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Guillermo from Miami, FL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Goldsboro, NC
Parts Used:
5303917590
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
Deforst Drain Pan rusted out
The old drain pan had a 1 ½” tall bushing attached to the center of the pan. The new pan did not have this bushing which was great. I had to cut about 1 inch off the bushing to remove the old pan. Also after cutting the bushing I had to screw the bushing off after cutting the old pan from the bushing. I installed new pan onto the ½” of threads that was left on the top of the compressor. Checked repair two days later all was great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronnie from Abbott, TX
Parts Used:
5317842502
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer was freezing up and would run all the time and not cycle off.
Unplug the refrigerator. You will ultimately need to remove the back panel of the freezer. But first, you will need to unscrew 2 screws on a small vertical fan vent and unscrew two screws on the fan. Maneuver the fan out of the round hole in the back panel and unplug the 3 prong wire connection. Then remove the fan. Unscrew the 4 remaining visible screwson the back pannel and remove the panel. This will expose the freon coils. On this model, the heater has two connections at the top of the coils. Unplug those wire connections. The heater extends down each side of the coils and along the bottom of the coils. Unhook two aluminum ties that connect the heater element to the coils. These ties stabilize the heater element and also prevents any current from flowing along the element because of the touching of two different metalic parts. Maneuver the heater element out of the coils. To install the new heater, reverse the above process beginning with installing the new heater element. If it hasn't already been done, it is good idea to test the old heater element with an ohm meter to make sure that the element is actually bad. The circuit should be open. This is the second heater element that I had to replace on this refrigerator, and it was actually burned in half both times, so I knew for sure the element was bad. Then test the new element to make sure it is good, and start the installation..
Was this instruction helpful to you?
Thank you for voting!
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GTN198WH1-45
16 - 20 of 20