RT12DKXEW00 Roper Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Stephen from San Jose, CA
- Parts Used:
- 4388931
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fridge went warm whilst the freezer continued to work. Meanwhile strange intermittent switching noise coming from above the lamp in the refrigerator compartment.
Switch off power at mains outlet. Pull off the front trim panel on the control box at top of the refrigerator compartment (it is just clipped into place). Behind are two screws which you remove. Remove the bulb and also two screws underneath and towards back of the control box. You can then pull down the control box. The defrost timer board is now visible and can easily be switched out (it comes with instructions how to do this). This job too no more than 20 minutes and saved me buying a new refrigerator at $1000.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph D. from Culpeper, VA
- Parts Used:
- W10373956
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
bottom door handle broke
After learning the top and bottom part separate from the handle itself, all I needed to do was to take off the bottom part which was broken and replace the broken part with the new part , that was in a kit, I purchase from Whirlpool.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Ledyard, CT
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Repalce evaporator fan
The evaporator fan is located in the freezer behind the back wall. If you have the ice maker remove it first then remove the screws on the top of the panel. You will notice the side brackets for the top shelf will make it hard to remve the panal but by slitly binding the center the panal came right out. The fan is held in a bracke tha comes right out. The wire unplu right from the fan so do not try to unplg the seal plug to the left side. Swap the fan with the new one useing the new rubber monts re-connect the wires and reasymble. Put the bottom of the back panal in first then work each side in past the shelf bracket binding the center slightly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Sierra Vista, AZ
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
rReally Noisy Fan
1. Unplug Refrigerator 2. Remove inside back freezer panel. (4 Screws) 3. Remove Duct Cover (3 Screws). 4. Cut electrical connections to fan. 5. Remove Old Fan motor (2 hex screws. 6. Install ground wire (was not one there previously). 7. Put slide-on electrical connectors on remaining 2 motor wires. (Were not any on original unit.) 8. Replace Fan Motor (Don't forget the rubber vibration pads) 9. Reconnect electrical wires. 10. Press on plastic fan blade. 11. Plug in refrigerator to test install. It works. 12 Unplug refrigerator and replace ducting and back panel to freezer. Plug it back in. Voila, Quiet again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Hilliard, OH
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Evaporator motor squeal.
After finding an almost obsolete part( thanks PartSelect!) the installation was rather easy. Remove the back panel of the freezer and vent with a screwdriver and a nut driver. Disconnect the three wires, green, white and red.Remove motor from mounting and replace with new motor. I had to make a slight adjustment to the ground wire on the new motor that required adjusting the position of the contact-no big deal. The motor fit perfectly. Popped fan on and assembled. 20 minutes max.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Radcliff, KY
- Parts Used:
- 4387913
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator would not get cold
Took a little while to figure out that I needed a flat tip screwdriver to lift up on the top of the plastic housing in order to tip it forward and remove it. After that I used pliers to remove the wires from the old parts and place them on the new. Removing and replacing the parts was performed by hand.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Brooklyn, NY
- Parts Used:
- 4387478
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Protective cover for bulb had melted
I tried to just replace the cover rather than the whole unit but it was impossible - the cover would not go/stay on. I tried to remove the old unit completely but it would not unplug it was practically fused to the back of the fridge and the liner was cracking. I ended up breaking the cover and jerry rigging it over the bulb to prevent items in the fridge from being able to touch. Bad solution.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Arlington, MA
- Parts Used:
- W11384469
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from St. Pete Beach, FL
- Parts Used:
- W11384469
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Broke the arm off the food compartment rocker switch
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eliseo from Pleasanton, TX
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
no problems at at all
removed rear wall panel took off old fan motor disconnected motor. Installed new grommets re-installed motor inserted new fan. Didn't have to trim fan re-connected wires and rear panel and reconnected power. no problems...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lucy from Portland, OR
- Parts Used:
- WP2201061
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
bent door shelf bars
I was able to replace the the shelf bars with no difficulty after finding the right parts on PartSelect. The easy to view measuring menu helped me get the right size for the fit I needed. You always worry when you don't have the item in front of you but they make it easy to gauge. I will use them again. I replaced three bars that had been driving me crazy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from Cincinnati, OH
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Noisy fan
Unplug the refrigerator. Remove the rear shelf supports by lifting them straight up. No tools required. Remove the screws holding the rear cover of the freezer. Use a nut driver to remove the 4 screws holding the fan housing. Unplug the wiring harness, then remove the fan and install the new one. Remount the housing, plug in the harness replace the rear cover, install the shelf supports and plug in the refrigerator. It was 30 minutes start to finish, which includes the time to gather the tools, unload and reload the freezer, and putting the tolls away!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Maxine from Henderson, NV
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The fan in the freezer was squealing
Took the old fan out and put the new fan in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Arvada, CO
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
noisey circulating fan in the freezer
Emptied the freezer. Removed the back panel. (six screws)Removed the fan cover.(4 screws) Unplugged the power. Unplugged three wires from the motor. (hot-neutral-ground)Removed the fan. (2 screws) Installed the new fan and centered for clearance. Reversed the prior instructions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jabez from Holland, MI
- Parts Used:
- 4387913
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Socket set
Freezer & Fridge warmed then stopped working
I oringinally thought it was one of the thermostats b/c the freezer started to freeze again after unplugging it. But then the next day it stopped all together and I could hear a clicking noise in the back and the compressor never turned on. It would click at around 2 minutes then again about 17 seconds later. I took photos of the original wires in the connector to match up later. The new parts were not identical to the old. The red wire on the bottom fit fine but the other two wires would not go in the same terminal or numbered positions (1&4). For 2 reasons, 1, the blue female was too small for the male and 2) there was a male missing at position 4. After looking at the guts of the old connector I decided to get new females (2 trips b/c I didn't buy a big enough wire opening - needed 2 wires) and cut, splice & crimp them. I then put the two females on the top two males & plugged it in. No sparks or explosions... but silence. I waited a few minutes and then the fan kicked on and then the compressor started running. That was Sunday, it's now Thursday and things are working well.
Was this instruction helpful to you?
Thank you for voting!