RS22AMXVW00 Roper Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from Murfreesboro, TN
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Fridge side freezing everything.
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control box to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allan from Allen, TX
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
refrigerator would not stay cold
The wife found if we tapped the knob for the cold control the appliance would turn on. Upon further inspection I found what looked to be carbon particles under the part. I found the part easily with partselect.com, ordered it, installed it and its like we have a new appliance.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Cary, NC
- Parts Used:
- W10190935
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
ice would not fall from ice maker
I ran all the ice maker module tests that I could find online, I tried cleaning the contacts inside the ice maker control module, nothing worked...so I finally decided to purchase a new control module. I had already had the module out and taken apart a few times, so the new one was very easy to install. Just removed the entire icemaker from the fridge, removed a few screws, took off the old module, put on the new one, replaced the screws, re-installed the icemaker in the fridge (it just slides in and out similar to a shelf). And 30 minutes later I heard the first batch of ice cubes drop! And by morning the bucket was nearly full. After two weeks of no ice and trying to fix it myself - the family was glad to have ice again (it was July in NC!). In retrospect, I should have followed the advice I found online and ordered the new part sooner and saved all of those frustrating hours of trying to "fix" the part myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jesse from hacienda heights, CA
- Parts Used:
- W10823511
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gerardo from el monte, CA
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
compressor didnt turn on
changed the starter connected to the compressor
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- brett from garland, TX
- Parts Used:
- WP2198202
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
freezer intermitently warmed to around 31 degrees
Being a jet mechanic I had to familiarize myself with refrigerators, then after 2 or 4 hours of online studying, opened the door pulled the temp knobs of, removed the panel by gently prying the top of the panel out,then up and out with it. I found tapping on the thermostat shaft or wiring connection started the compressor, verifying my belief it was the thermostat. Don't mess with wiring if you don't know exactly what you are doing and unit is plugged in, you will electrocute yourself!!! I received the thermostat, UNPLUGGED THE UNIT from the house wall outlet, took one screw out of the upper inner wall at the very top to remove cover, one screw at the back top to remove the other cover (at the control vent) for access to remove sensor, then removed 4 screws , 2 front, 2 underneath to drop the housing for defrost timer, etc., and then took 2 screws from thermostat, unplugged wiring from thermostat (3 wires, be sure to put them back on the same place in the new thermostat). Remove old thermostat, slide plastic cover off sensor and slide back onto new thermostat sensor. Be careful not to kink the line or bend it to sharp you will damage it, (use gentle curves when bending it,) and re assemble everything in reverse order. This took about me 15 or 20 minutes start to finish. Plug into wall and watch thermometer to verify success.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leo from Lewisport, KY
- Parts Used:
- WPW10151374
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Unable to set the cold-control to a sufficiently cold setting.
Linkage on the cold-control mechanism in the air diffuser assembly was broken. It was necessary to access the diffuser assembly from both the refrigerator and freezer sides of the unit.
Re-connected the linkage between the diffuser and cold-control assembly; remounted the two combined assemblies . . . refrigerator working nicely now.
Re-connected the linkage between the diffuser and cold-control assembly; remounted the two combined assemblies . . . refrigerator working nicely now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Pryor, OK
- Parts Used:
- W10190935
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Following a brief power outage, it stopped producing ice. Harvester was at 6:00 with fingers frozen in ice cubes. Would make a batch if I freed the harvester and jumped the t-stat, but would quit again.
Unplugged refrigerator. Used nut driver to remove small bolt retaining wire cover on right side of ice maker. Removed wire cover, used flat head screw driver to depress side-rail clips. Ice maker slid out, unplugged. Timer module cover pops off easily. Three screws removed the timer module. Installation was reverse of removal. Had ice in less than an hour, bin was full by next morning. If you have a screw driver and know what it's for, this job should come easily.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- bill from escondido, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from New Braunfels, TX
- Parts Used:
- WP2182124
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice stripper broken on ice maker
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Aledo, TX
- Parts Used:
- W10190935
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
icemaker quit working
removed screws that held the ice maker in place, then removed the cover (popped off) The drive element was easy to remove, three screws and it was out. I put in the new part and reinstalled the icemaker with the three screws that hold it in place. I never call Sears for any repair. They use contract help and I have heard horror stories about those guys!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Byron from Steamboat Springs, CO
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Ice water valve leaking
Removed two screws holding valve, removed two 1/4" water lines. disconnected wire clip from old valve.
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Cedarville, OH
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers, Socket set
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Martin from Shakopee, MN
- Parts Used:
- WPW10190929
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice stuck in mold. mold coating was peeling off.
Turn off water supply too ice maker and unplug the fridge power. using a nut driver remove one bottom screw from the bottom, near the front. The other two from the side atop the ice mold. (loosen screws and ice maker will lift up and off.)
I set the ice maker on the counter, snapped of the front cover by hand. using a phillips driver, remove two screws near the bottom corners.(they go through the circuit board into the ice mold)
circuit board in one hand, other end of ice mold in the other, slowly pull apart about 1 inch. remove the silver colored "on, off" bar at the end by snapping the retainer out of the ice mold. (the silver bar stays with the circuit board end)
Watch how the ice guide(white fingers stationary on side of ice mold) hooks too the ice mold on each end. swap ice guide to new ice mold, insert three guide pins on end into holes on the circuit board, while holding ice guide onto ice mold, watch rotation bar while inserting into motor.(it only splines one way.) when each piece is lined up, simply push together and reinstall two screws. snap circuit board cover into place. reinstall ice maker into freezer in reverse order.
I set the ice maker on the counter, snapped of the front cover by hand. using a phillips driver, remove two screws near the bottom corners.(they go through the circuit board into the ice mold)
circuit board in one hand, other end of ice mold in the other, slowly pull apart about 1 inch. remove the silver colored "on, off" bar at the end by snapping the retainer out of the ice mold. (the silver bar stays with the circuit board end)
Watch how the ice guide(white fingers stationary on side of ice mold) hooks too the ice mold on each end. swap ice guide to new ice mold, insert three guide pins on end into holes on the circuit board, while holding ice guide onto ice mold, watch rotation bar while inserting into motor.(it only splines one way.) when each piece is lined up, simply push together and reinstall two screws. snap circuit board cover into place. reinstall ice maker into freezer in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- sandra from mechanicsville, VA
- Parts Used:
- W10190935
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
ice dispenser broken
ridiculous how a tiny plastic broken part required a full motor assembly replacement. that being said, i went online, found this website and easily identified the part i needed to order. i was impressed when it arrived within a couple of days. removing the old motor and replacing the new was a piece of cake...and i am NOT mechanically inclined,
Was this instruction helpful to you?
Thank you for voting!