Customer:
bradley from MCCONNELSVLE, OH
Parts Used:
2188445A
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
ordered a replacement condenser fan kit. kit motor rotated backwards blowing air out instead of inwards over condenser.
Looked up on youtube. found a guy who said that the shaded pole motors are made in china and rotate backwards. (design flaw) so, he had a 4 minute tutorial on how to reverse the motor and it runs the correct way.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from CIRCLEVILLE, OH
Parts Used:
819100
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
freezer quit working
replaced relay switch
when I finally got started to do the repair it took 15 minutes my biggest delay was no instructions were sent with the part and it took time to get some
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MIKE from ARLINGTON, OR
Parts Used:
482731
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Mounting bracket was riveted on old motor, mounting bracket holes on new motor were different
removed shims on screws holding motor together, enlarged hole in mounting bracket so motor screws could also go through mounting brackets.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jacqueline from LEXINGTON PK, MD
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
No cold
Like you video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from GLOVERSVILLE, NY
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from HELENDALE, CA
Parts Used:
WPW10662129
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer would not freeze
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thick. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
anthony from NORCROSS, GA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Freezer no longer frost free.
Reviewed Youtube video as a reference. Unplugged refrigerator. Removed old defrost timer. Matched the color of the wiring harness to the diagram that came with the part. Attach new part to wiring harness.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from MERRIMACK, NH
Parts Used:
WP2196157
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Connection leaked as tube entered freezer
Followed video and had one problen, the metal pipe would not release as shown,so I used a hacksaw between the plastic and metal pipe, removing the metal pipe from inside as the video shows. Good instructions.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from FORD CITY, PA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Freezer occasionally had a temperature alarm.Clicking noise also.
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christine from WASHINGTON, DC
Parts Used:
819342
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
End cap of fridge door had failed
Simple to unscrew and replace parts
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from REDDING, CA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Warm refrigerater
Followed instructions from ideoo
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Lancaster, CA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cecelia from Garden City, TX
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer made lots of Ice and Refrigerator didn't cool
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator brand new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.
4 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Colorado Springs, CO
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Fairfield Glade, TN
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer Cold - Refrigerator Warm
After searching online to diagnose the issue with my refrigerator being warm and the freezer being cold and not shutting off to defrost I decided to get the defrost timer kit. The kit arrived within 2 day. With the directions included, after unplugging the appliance for safety, I installed it relatively quickly with only a screwdriver . I then plugged it back in and it immediately went to defrost. I thought, wow I have it fixed. Well unbeknownst to me it still didn't cool in the fridge area. After doing more internet research I found a suggestion to unplug the fridge for 24 hours to unthaw ice that may be lodged between the freezer and fridge that is blocking the distribution of cold air into the fridge. After doing this, it now works like a charm.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!