RT14ZKXDW00 Roper Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Joseph from Destin, FL
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light switch would not work
Popped the old one out with a kitchen knife and popped the new one back in. It tool less than 15 seconds!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jackie from Nova, OH
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Switch was not working after a repairman had fixed something else
Please bear in mind I am 65 years old & it was harder to get up & down off the floor then to change the switch. Was very easy - watched video, unplugged unit. I used the putty knife at the right front corner to work loose, when it came loose had to loose the left side a little. The unit pulled out easily. detached the wired that had a single plug with 2 prongs on it. Attached the plug, pushed new switch into place. There was no way you could place wires on wrong prong. When done, plugged refrigerator back in & checked if working. I CAN SEE THE LIGHT and the food in the freezer now. Thank you for making an easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Howard from Boynton Beach, FL
- Parts Used:
- 350930
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Both outside door handles turned very beige
Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Arvada, CO
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
noisey circulating fan in the freezer
Emptied the freezer. Removed the back panel. (six screws)Removed the fan cover.(4 screws) Unplugged the power. Unplugged three wires from the motor. (hot-neutral-ground)Removed the fan. (2 screws) Installed the new fan and centered for clearance. Reversed the prior instructions.
Was this instruction helpful to you?
Thank you for voting!
Cold air not flowing between freezer and refrigerator sections
Replaced air baffle between sections - part number PS321610. This part is quick connect with no wiring required. Start by turning off appliance using thermostat dial on freezer side. Remove cover for air baffle in upper left rear corner of refrigerator compartment. Remove wire harness cover between air baffle assembly and front upper control panel of refrigerator. Remove screw covers from under upper front control panel in refrigerator. May need to pry them off with a butter knife or thin screwdriver. Pull off thermostat dial. Unscrew mounting screws to remove upper front control panel cover. Pull out old air baffle assembly but do not unplug wire harness. Slide new air baffle assembly into position. Following the old part's wire harness, run wire harness for new part to point where old wire harness connects. Match up the old and new wire harness connections, unplug the old wire harness and plug in the new wire harness making sure the wires for the old and new correspond. Remove the old part and wire harness and secure the new part wire harness in the wire harness track. Reinstall the front control panel cover and thermostat dial and the screw hole covers. Reinstall the wire harness cover. Reinstall the baffle door cover. Turn the appliance on. You have now saved yourself a few hundred dollars in labor costs!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Maxine from Henderson, NV
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The fan in the freezer was squealing
Took the old fan out and put the new fan in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Arlington, MA
- Parts Used:
- W11384469
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jabez from Holland, MI
- Parts Used:
- 4387913
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Socket set
Freezer & Fridge warmed then stopped working
I oringinally thought it was one of the thermostats b/c the freezer started to freeze again after unplugging it. But then the next day it stopped all together and I could hear a clicking noise in the back and the compressor never turned on. It would click at around 2 minutes then again about 17 seconds later. I took photos of the original wires in the connector to match up later. The new parts were not identical to the old. The red wire on the bottom fit fine but the other two wires would not go in the same terminal or numbered positions (1&4). For 2 reasons, 1, the blue female was too small for the male and 2) there was a male missing at position 4. After looking at the guts of the old connector I decided to get new females (2 trips b/c I didn't buy a big enough wire opening - needed 2 wires) and cut, splice & crimp them. I then put the two females on the top two males & plugged it in. No sparks or explosions... but silence. I waited a few minutes and then the fan kicked on and then the compressor started running. That was Sunday, it's now Thursday and things are working well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kurt from Baltimore, MD
- Parts Used:
- 482731
- Difficulty Level:
- Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench set
Evaporator fan motor stopped working
Remove back cover of freezer compartment; Remove old fan assembly, new fan terminals did not exactly match old one so I had to remove one of the terminals from old fan and attach it to new fan/ then install new assembly and repaced freezer cover
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Laramie, WY
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lucy from Portland, OR
- Parts Used:
- WP2201061
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
bent door shelf bars
I was able to replace the the shelf bars with no difficulty after finding the right parts on PartSelect. The easy to view measuring menu helped me get the right size for the fit I needed. You always worry when you don't have the item in front of you but they make it easy to gauge. I will use them again. I replaced three bars that had been driving me crazy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Brooklyn, NY
- Parts Used:
- 4387478
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Protective cover for bulb had melted
I tried to just replace the cover rather than the whole unit but it was impossible - the cover would not go/stay on. I tried to remove the old unit completely but it would not unplug it was practically fused to the back of the fridge and the liner was cracking. I ended up breaking the cover and jerry rigging it over the bulb to prevent items in the fridge from being able to touch. Bad solution.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Radcliff, KY
- Parts Used:
- 4387913
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator would not get cold
Took a little while to figure out that I needed a flat tip screwdriver to lift up on the top of the plastic housing in order to tip it forward and remove it. After that I used pliers to remove the wires from the old parts and place them on the new. Removing and replacing the parts was performed by hand.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eliseo from Pleasanton, TX
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
no problems at at all
removed rear wall panel took off old fan motor disconnected motor. Installed new grommets re-installed motor inserted new fan. Didn't have to trim fan re-connected wires and rear panel and reconnected power. no problems...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Hilliard, OH
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Evaporator motor squeal.
After finding an almost obsolete part( thanks PartSelect!) the installation was rather easy. Remove the back panel of the freezer and vent with a screwdriver and a nut driver. Disconnect the three wires, green, white and red.Remove motor from mounting and replace with new motor. I had to make a slight adjustment to the ground wire on the new motor that required adjusting the position of the contact-no big deal. The motor fit perfectly. Popped fan on and assembled. 20 minutes max.
Was this instruction helpful to you?
Thank you for voting!