Customer:
Thomas from Leesburg, FL
Parts Used:
W10508993
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Shelf Bracket
Removed food itmes on broken shelf. Removed old glass shelf cover. Removed broken shelf bracket. Installed new shelf bracket. Intalled new glass shelf cover. Replaced food items back on shelf
26 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
douglas g. from roanoke, VA
Parts Used:
WP2188664
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken meat and vegatable draw
a simple replacement
25 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Fairfax, VA
Parts Used:
8201707, WPW10329686
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
refrigerator door wouldn't remain closed
The plastic lower door closing cam was worn down. Replacing it was very simple: remove the top door hinge by unscrewing three nuts; lift the door off the lower hinge; unscrew and remove the lower door hinge; screw the new plastic lower door closing cam on to the new door hinge; screw the new lower door hinge; lift the door back on to the lower door hinge; screw the top door hinge.
26 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jay from Oconomowoc, WI
Parts Used:
WP2182179, WPW10329686
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Refrigerator door fails to close on its own like it is designed to.
The design of this refrigerator door (it's a side-by-side) is somewhat unbelievable. The door is designed to hold things, yet when you do the weight of the door wears out the lower door cams. The cams are designed to "complete the door closing", i.e. when you gently push on the door the cam mechanism takes over. When the cams wear, the door fails to close. Note to others - you may mistakenly think that the failure of the door to close is related to the seal; it is not.

The repair is quite easy; remove the upper cover, using a not driver (socket), then remove the upper door bracket. Make sure you hold the door or have someone else hold it. After the fasteners are removed gently lift up on the door and remove it from the lower cam assembly. You will see two plastic cam pieces; one on the lower bracket and one on the door. Both need to be changed to effectively "renew" the door closing mechanism. Once the cams are replaced the door can be reassembled to the refrigerator.
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Sandy, UT
Parts Used:
W10823377
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Ice Door would not close
I removed the Ice door front cover on freezer door. Found door pivot was broken. I installed door pivot bracket, and dashpot in kit. I used most of the kit to repair it. The door now works like new. Thanks for the right parts Frank
26 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sean from Boise, ID
Parts Used:
WP2304673
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Water dispenser hose tip broken.
The part to fix this was a $50.00 part.
I purchased this Bracket Dispenser for $6.00 and it fit on My fridge perfectly. I just used the screw hole that was a little higher on the water dispenser. Simply cut off the broken end / or Buy a new Hose (Cost at Lowes about $6.00) guide hose along the bracket and use a socken set to reinstall the screw. Water is not squirting on people any more.
26 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerome from Decatur, IL
Parts Used:
W10822681
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
valve leaking due to being frozen in storage
removed old valve after finding out it leaked really bad. Got on line ordered new valve and it arrived in one day. great service from you guys. there was a little difference in the valves, push in line fitting on the new valve, screw in fittings on the old one. took less than 20 minutes to install and works great, thanks
54 of 118 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Greeley, CO
Parts Used:
WP2182181, WP2182179
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Refrigerator door failing to close without being pushed shut
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
25 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Winston-Salem, NC
Parts Used:
W10823377
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
ice distribution door broke
At their site was ordering each piece by # and cost and it was adding up to be costly. Went to partselect and was doing the same and up pops the ice door kit. Was a little wary because my original had a heater tape to it. Got the kit and installed not a problem at all. 100% satisfied would recommend to anyone.
23 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Julia from Seguin, TX
Parts Used:
8201597
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
There was a pin size hole in the tube.
It was pretty easy to install. The most difficult part was trying to get my hands into the small area to work. I had to use both hands, one to push the release in and the other to pull the tube out. Once I did that, inserting the tube was easy and everything worked perfectly.
25 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nancy from Hilton Head Island, SC
Parts Used:
WPW10321304
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
plastic door shelf was cracked & couldn't hold any weight
looked up the model #, found your co. & ordered a new one Service was excellent, shipping reasonable; it was a pleasant surprise. I will tell my friends about your co.
20 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Hammond, LA
Parts Used:
8201515
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Magic Plus stopped making ice
First I removed the icemaker from the freezer by removing two horizontal screws holding it to the side wall, and one vertical screw holding the front to a bracket coming off the side wall. Then I used a flat screwdriver to unlock the electrical plug. (After doing this, I realized that this wasn't necessary at all, and this part could have been changed just as easily without removing the icemaker.) On the front, there is a white cover with Ice Maker Plus. Use a flat screwdriver to unlock the tangs and remove the cover. There are three screws in the corners that once removed, will allow the motor assy. to be gently pulled straight out. On the back of the part, you will see many gold lands that the timer touches. I don't think there was anything wrong with my motor. I had two spots where the gold plating was worn off, so I suspect it was not making contact, and the whole process would stop. Slide the new part in place making sure the teeth on the gears line up (not a big deal), and secure with the screws. Install cover and you're done. Mine has been making ice like it was brand new.
25 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason from Farmland, IN
Parts Used:
WP2188664
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken drawer
Put new drawer in fridge.
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Findlay, OH
Parts Used:
EDR5RXD1
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
water filter needed changed
Turned the lock knob on the filter and removed. put
lock knob on new filter and installed.

Very user friendly website, would highly recommend to anyone.
22 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Valencia, CA
Parts Used:
W10823377
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice dispenser freezing up, dispenser door not closing completely.
First off, if you have the stainless steel panel inserts on your refrigerator you'll need to remove those to do this repair. I kept looking for the access holes on the underside of the dispenser panel that you're supposed to insert a screwdriver into to pry it off. It wasn't until I removed the freezer door handle, slid the lower stainless panel insert out, and removed the rail just beneath the dispenser that I could see and access these holes. I also removed the upper stainless panel and rail just above the dispenser to allow enough movement get the dispenser cover off and out. The rest of the repair is pretty straightforward. The old ice door was beaten up and not closing completely, this was letting warm air into the freezer which was melting and re-freezing. This kit fixed the problem.
22 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the MSD2269KEA02