MBV1976AAB Maytag Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- James from Naples, FL
- Parts Used:
- 11001182
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
Maytag SkyBox would not dispense
First removed the two screws that hold the flapper door switch in place. Then unplugged door from main unit and removed door. Removed the door gasket. Placed door face down on table and removed about 14 screws to expose the the plug end of the switch assembly.
Plug in the new switch assembly and thread thru hole. Reinstall the door panel. Reinstall the gasket. Reinstall the switch cover. Rehang the door and plug to main unit. The machine now properly dispenses cans.
Plug in the new switch assembly and thread thru hole. Reinstall the door panel. Reinstall the gasket. Reinstall the switch cover. Rehang the door and plug to main unit. The machine now properly dispenses cans.
Was this instruction helpful to you?
Thank you for voting!
Machine reported a jam every time a can was dispensed
Removed fridge door by opening all the way and lifting up ( don't forgit to unplug wire harness)
Removed all screws on back side holding two faces together, replaced parts.
Removed all screws on back side holding two faces together, replaced parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Mooresville, NC
- Parts Used:
- 11001182
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Maytag Skybox LEDs flash won't dispense
Door flapper sensor malfunctions and will not dispensense more than 1 without reseting appliance by opening and closing the door. Remove 2 screws by sensor. Remove door seal. Under the door seal remove 14 screws that hold door facing on. plug new sensor cable into board and reassemble. Count on doing every 2 - 3 years. This part is destroyed by condensation so consider stocking up on it, who knows how long it will be available.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GREGORIO from MORTON GROVE, IL
- Parts Used:
- WP11001124
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
cooling fan was not coming on
took unit apart fan not working replace pc broad &fan works fine
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Valley City, OH
- Parts Used:
- WP11001154
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
No Status Lights on Control Board. No 12vdc coming from Transformer.
1. Unplug power.
2. Removed the screws holding on the access panel on rear of machine.
3. Remove 4 screws holding plastic cover from motherboard enclosure.
4. Replace the transformer and connect wires as they were on the old transformer.
6. Replace the cover with the 4 screws.
7. Replace the access cover.
2. Removed the screws holding on the access panel on rear of machine.
3. Remove 4 screws holding plastic cover from motherboard enclosure.
4. Replace the transformer and connect wires as they were on the old transformer.
6. Replace the cover with the 4 screws.
7. Replace the access cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Marshalltown, IA
- Parts Used:
- WP11001154
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
no lights on will not despence and will not chill
2 screws on trans one plug in on mother board and the 2 plug in power wires ( easy ) repaired, second time doing it
Was this instruction helpful to you?
Thank you for voting!