Models > RB19FA-2AL > Instructions

RB19FA-2AL (7C38B) Magic Chef Refrigerator - Instructions

Jump to:

All Instructions for the RB19FA-2AL
121 - 135 of 141
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
larry from indianapolis, IN
Parts Used:
833697
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Socket set, Wrench set
not cooling
removed condenser fan -located behind refrigerator next to compressor, Not much clearance to work, there are 3 screws to remove from condensing motor,sounds easy but clearance is lacking to remove them ,(takes alot of PATIENCE). Then you have to remove the fan blades to be able to get clearance to remove motor!! I wouldn't reccommend trying this repair unless you are a pro.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Sykesville, MD
Parts Used:
WP60106-35
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set, Wrench set
Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Greenville, OH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Condenser motor stopped working
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from New Albany, IN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nancy from Gallatin, TN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
condenser fan wore out
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Laramie, WY
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from River Edge, NJ
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
exchange of defective light rocker switch
1)pry out the old/defective light rocker switch with a screw driver (flat head) and pull out the cables 2)unplug two connectors at the end of light rocker switch 3) connect new light rocker into two connectors 4)push the wires inside and put back new light rocker switch
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Fairport, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light in the refrigerator didn't work
I did exactly as the video showed. I popped out the old switch, disconnected the two terminals, connected the new switch and put it back. The light now works! The refrigerator is over 25 years old and the switch works! What a great website this is. Couldn't of done the job without Partselect's help.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from LAS CRUCES, NM
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Myrna from Decatur, IL
Parts Used:
833697
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Fan motor worn out
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's working fine now and I'm a satisfied customer!
Was this instruction helpful to you?
Thank you for voting!
Customer:
patrick from livonia, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dale from Sterling, AK
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
wouldn't make ice, door seal was hot to touch, warm in fridge.
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Honz from Tucson, AZ
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Socket set
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Strafford, NH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Socket set
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Batavia, OH
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RB19FA-2AL