RC20LN-3BW-BS08A Magic Chef Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- John from Greensboro, NC
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Westcliffe, CO
- Parts Used:
- 12001773
- Difficulty Level:
- Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
all 8/32 and holes should have been tapped
had to saw off the shaft to get the yoke off and tap the holes for the 8/32 screws. all holes should have been tapped by the factory. Other than these problems, everything else went pretty good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cami from Carmel, IN
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
evaporator coils were frozen solid and air wasn't flowing across them
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Granada Hills, CA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- craig from green bay, WI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
icemaker quit working
I took out 1 screw , unplugged the icemaker and lifted it out and installed the new one and had ice in no time at all. can't get much easier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Loren from Indianapolis, IN
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker Leaked Creating an Ice block
Merely remove the front bottom screw that attached the ice maker to the refrigerator
Lift the ice maker gently off of the 2 top screws
Unplug the icemaker wiring harness from the back of the refrigerator, and remove
Snap off the end of the maker and remove the keeper for the wire arm
Remove the wire arm and install on new maker
Unplug the wiring harness from the old maker and plug into the new one
Plug the harness into the refrigerator, slip the new maker over the top screws, with the water feed tube inserted into the maker
Install bottom screw into the bracket that holds it in place.
This took less than 5 minutes.
Lift the ice maker gently off of the 2 top screws
Unplug the icemaker wiring harness from the back of the refrigerator, and remove
Snap off the end of the maker and remove the keeper for the wire arm
Remove the wire arm and install on new maker
Unplug the wiring harness from the old maker and plug into the new one
Plug the harness into the refrigerator, slip the new maker over the top screws, with the water feed tube inserted into the maker
Install bottom screw into the bracket that holds it in place.
This took less than 5 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Clinton Corners, NY
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Replaced Ice Maker
Followed the online PartSelect video instructions and it was very helpful. The ice maker has to cycle through before it starts making ice so don't be alarmed when nothing happens when you first hook it up.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- craig from maple grove, MN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jackson from Leesburg, VA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Replaced leaking ice maker after minor screwup!
Old ice maker leaking water and produced ice cubes with black inclusions. First, I removed old ice maker per video instructions. Transferred electrical cable, cover, and bail to new ice maker. First installation failed because I failed to make sure water tube correctly enter back of ice maker. No ice. Initially thought electrical cable wasn't firmly in place. Then I noticed frozen water dripping down back of freezer. A clue! Removed ice maker and reinstalled making sure water tube went through the hole in back of ice maker. Now the new ice maker works beautifully!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Richmond, VA
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
Ice Maker couldn't drop ice through the door.
I pulled the drive ring off of the icemaker and replaced it with the new part. Saved a $150 service call plus cost of part. It cost me a little over $11.00 and a repairman probably would have charged $30.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Samuel from ALEXANDRIA, VA
- Parts Used:
- WPB5705307
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
Ice from icemaker taste metallic; new ice maker directly from box
I did not do the repair yet, there is no schematic on how to route the hose; also no description of how to do the routing/connections.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Oak Hill, VA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ice Maker Stopped Working
This was a very easy fix. I took the old ice maker out, including the electrical harness. Switched the harness and stop bar to the new ice maker on my bench, then installed the new assembly. Ice initially had some hollow cubes. I checked the ice maker for level. But it was fine. Thought it might be moving too fast. But it seems to have cleared up. Perhaps it took some time to completely cool down.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bobby from HARLEM, GA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Icemaker stopped making ice
Model#MBF2255KEW (bottom Freezer) Turn fridge and freezer controls OFF. Move fridge out away from wall to give yourself working space and to clean later. Disconnect electrical plug from wall. Turn off water supply at wall or floor. Put down towel to catch excess water and disconnect water hose at water supply, lay it on towel. Move to the inside of freezer and remove freezer bins by pulling the door all the way out as far as it will go and then lifting by the handle up. locate the two hooks in the back and push forward to clear the bar and move to a safe location. Push the two rails all the way back into the freezer. Un plug wire harness from freezer by squeezing both side of the plug at same time and pull off. Remove the 3- 1/4" nut screws (2 at top and 1 at bottom ) from the ice maker and remove. Take the front cover, Wiring harness and wire bail from old ice maker and place it on the new ice maker. Install new ice maker and connect the wiring harness plug to the freezer connection. Hook up water line hose and tighten. Turn water on and check for leaks. Plug fridge into wall outlet and set refrigerator and freezer controls to 3 until refrigerator is cold and then set as needed. Give the ice maker from 3 to 6 hours to freeze and wait for that magical sound of ice being dumped into the bin. Throw away first batch of ice to make sure there are no impurities. Check for the delivery date of the new ice maker before you start and have coolers and ice for perishables. I removed the old one on the delivery date and cleaned the fridge and freezer inside out. I came to this page to get my repair plan and I hope this will help someone else.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frankie from Panama City, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Cracked Ice Maker causing leak
Removed old ice maker, had to use the wire shutoff from old ice maker installed new one. Very easy repair, very nice product cheapest price on internet.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nancy from Englewood, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
install new icemaker
First had to remove baskets and door from freezer. Removed three screws; removed old ice maker; Attached new ice maker with three screws; removed arm from old ice maker and placed in the new ice maker. Replaced door and baskets
Was this instruction helpful to you?
Thank you for voting!