Rodolfo from South San Francisco, CA
Parts Used:
12002783
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Freezer/Refrigerator Stopped Cooling
Problem: My Maytag side by side door refrigerator just stopped cooling and have to discard all frozen items after I discovered being away for 3 days. First, I went to my computer and read some of the repair stories at Part Select “Need help with your repair?” and installation video guide.
1. I ordered the Refrigerator Adaptive Defrost Board (ADP) - followed the procedures how to disconnect and installed the new part. Unfortunately, it did not correct the problem and only warm is coming out.
2. I ordered the Defrost Heater Thermostat Assembly - removed the old and replaced with new assembly. Again, warm air coming out. Meanwhile, I kept on hearing “clicking sound every few second” not knowing where this coming from. Again, at Part Select, I read the story about it and I ordered the
Run Capacitor and the Overload/Relay with Capacitor. Soon as I opened the parts and tried to match it from the part at the back of the refrigerator and to the part from the compressor, I have discovered that they are not in compatible with the original parts from my Maytag Refrigerator and cannot be installed. And so I contacted (Email) Part Select customer service (Jeanette) if I could return the unused parts and had provided me the “Return address and the Reference Number”. This time, I gave Jeanette the Maytag Model and Serial numbers and asked where I could find this on my refrigerator and make the necessary repair and came back with the diagram and located #4 to the compressor. Ordered the correct part# PS2004058.
3. Upon receipt of the part above, I was puzzled, in the plastic container are four parts, included a plastic cover. I have not given up, I removed the original part encased in white plastic container pulled straight off the compressor and examined it closely. Before detaching all the wiring, I also noted before disconnecting from wire harness and read the Diagram/Instruction Sheet provided.
4. From the four new parts provided, installed the Overload Terminal, bottom part on Compressor with one terminal to the Blue wire. Connected White Jumper to the old harness. Lastly, I plugged the PTC Start Device (two terminals) above the Overload Terminal on the Compressor with the proper wiring as I previously noted and installed the electrical cover. “Plugged in the refrigerator to the power outlet”. To test the result, I left a glass of water inside the freezer and a bottle of wine into the refrigerator. The result - I checked after 2 hours, the water was frozen and a cool wine. “Little frustration included here, as I am not an electrician.” But now, I could say, I fixed it, and very proud of this accomplishment.
Thank You, PartSelect and to a great Customer Support!
Safety Note: Always make sure to unplugged the refrigerator (power off) prior doing the necessary repairs.
Rodolfo Julao-S.San Francisco, CA
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from colonia, NJ
Parts Used:
12001991
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
automatic ice door would not open
removed the front panel on freezer door ,removed and disconnected panel ,removed panel containing solenoid,replaced with new solenoid. replaced all parts. works perfect..
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from DAVISBURG, MI
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker stopped making ice
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Aliki from Miami, FL
Parts Used:
WP628356
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
riley from CAVE CREEK, AZ
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BRUCE from SHERIDAN, AR
Parts Used:
61005626
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set, Wrench set
Not despencing ice.
replaced water valve, Still not working.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Maria from Miami, FL
Parts Used:
12001991
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Ice dispenser flap broke off letting warm air inside freezer
Thank you for the easy to install video. I do much better hands on repair than reading the instructions. It was supper easy and it works great. My 11 year old son said to me "WOW mom great job" since I did it myself! I will definitley use you again for any other parts I need.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Hemet, CA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ross from Sun Lakes, AZ
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from Panama City Beach, FL
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Gurnee, IL
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Old Ice Maker failed
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the new unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Moore, OK
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Birmingham, AL
Parts Used:
61005626
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
pin hole opened up in 1/2 of double valve as a water leak
Turned off main water line at frig. disconnected water line. Lossened 1 screw- removed old unit and cut the two water lines going to the ice and water outlets. Pushed the water lines into the quick connects of the new unit --reconnected the water line-- rescrewed the unit to frig. turn on water . it was fixed.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?