RC20LN-2A Magic Chef Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- rolando from round lake beach, IL
- Parts Used:
- WP61001846
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
ice accumulating on evaporator of freezer.
Removed ice maker bin,removed screws on back panel cover. Pulled out panel cover,thawed accumulated ice, unscrewed bracket holding defrost heater set, unplugged busted defroster, plugged in new defroster set,installed it back, installed back panel cover, ice maker and powered it on.More than a week after installation,I don't see any signs of ice accumulation on back panel cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jon from Leander, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Black flecks in the ice
I made use of instructions for other users, see 'My ice maker has been shedding.....' and they were very helpful. The one problem not covered - the instructions that came with the new icemaker said to 'remove the bearing and inlet from the old icemaker and install in the new icemaker', but gave no instructions for how to accomplish this.
The old inlet has a square opening in the back and a u-shaped knockout in the side. The new one has a round opening in the side and square knockout in the back)
After several attempts to remove them, I gave up and used the new inlet with the knockout removed. I did not attempt to cover the side opening and it worked fine that way - no leaks.
The old inlet has a square opening in the back and a u-shaped knockout in the side. The new one has a round opening in the side and square knockout in the back)
After several attempts to remove them, I gave up and used the new inlet with the knockout removed. I did not attempt to cover the side opening and it worked fine that way - no leaks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CHRIS from BAYTOWN, TX
- Parts Used:
- WP61001846
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrigerator compartment warming up
The can drinks in refrigerator were not as cold as usual. I opened the freezer and touched the back panel and noticed there was a frost buildup. Since I have had this problem before, I knew that the defrost heater must be bad. I removed all the shelves and the tracks. The back panel is held in by 8 small sheet metal screws. I removed the screws and pulled the back panel up and out. The refrigerator is in garage, so I put a fan in front of it and the fan melted the ice off the coils. I disconnected the wires and checked the the heaters (both wired together) with an ohm meter. The meter showed the heaters to be open. (bad). Actually only 1 of the 2 heaters were bad, but I replaced both of them since they are wired together as a set.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Curtis from Barrington, IL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Old ice maker started leaking
Took under 5 minutes. Removed two screws and unplugged the wire bundle from refrigerator. Removed old unit. Put old wire bundle on new unit. Plugged wire bundle back into refrigerator and remounted the new ice maker. Could not have been easier. Watched the video first, it was very helpful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Northglenn, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Not making ice, and water leaking in freezer
Unplugged the power, removed old icemaker by removing 3 screws and unplugging a small wire harness
Then i moved the wire harness off the old one to the new one, moved the end cover over to new one and plugged the harness back in and screwed it back in and turned it on
ALL FIXED!
Then i moved the wire harness off the old one to the new one, moved the end cover over to new one and plugged the harness back in and screwed it back in and turned it on
ALL FIXED!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from rochester hils, MI
- Parts Used:
- 12002087
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
lights did not work
pulled out old socket and replaced supposed to be a duel socket but no longer exists
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Lancaster, PA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
water leak and frezes ice in bin
to easy to describe, remove 3 screws and a wire plug then install new unite.
Works great
Thanks
Works great
Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Yafa (and David) from Bothell, WA
- Parts Used:
- 8009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffery from vero beach, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
water overflow,coating on tray peeling off
remove 3 screws,rotate assembly,depress lock on wire harnass connector,un plug harnass.remove old assembly,remove and transfer side cover and steel wire at front of assembly,connect harnass to new assembly,rotate into place,aling screw holes and install 3 screws.flip front steel wire down and wait for about 1 hour,first tray of ice will fall..all done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sara from Nashville, TN
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Old ice maker stopped working
Removed the old icemaker and installed the new one. The first one we ordered lasted about 4 weeks and pooped out. Parts Select was very nice and gracefully sent another in two days time. This one has been installed and is working fine...Hope it stays that way.
Thanks...Ron Norwood
Thanks...Ron Norwood
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Doug from Lewisville, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker putting black pieces of plastic in the ice
Replaced ice ice maker using
All of the instructions on the website.
Very easy. A couple of the screws I had
To feel for because I couldn't gety big head
In the freezer far enough to see them.
Very simple and only took about 15 minutes.
All of the instructions on the website.
Very easy. A couple of the screws I had
To feel for because I couldn't gety big head
In the freezer far enough to see them.
Very simple and only took about 15 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from East Northport, NY
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set, Wrench (Adjustable)
Ice maker working with no production of ice
Turn off the water source and unplug freezer. Remove copper tube and then remove valve from back of refrigerator. Disconnect plastic tube and power connection. Mark power connection plug top with a "T", this reminder helps with the new valve. Plug power and plastic tube into new valve and screw assembly back into refrigerator. Using a wrench, connect copper tube into valve. Restore water source and plug back in in freezer. Within a couple hours, ice production was back.
Like the other repair stories (that helped me), this job was very easy.
Like the other repair stories (that helped me), this job was very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- chris from manvel, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker flaked and leaked leaving big glob of ice
Unplug wire harness back of fridge. Unscrewed 4 screws on guide for ice bin. then unscrewed two screws holding ice maker to wall of fridge. removed ice maker. then had to take front cover off (pull hard, it comes off) and remove wire harness plug from the ice maker. save this, front cover, and all hardware to re-use. reverse steps to reinstall, including wire guide that goes up and down to stop and start ice maker when bin fills. Have to put this into front part of ice maker correctly for it to work. make sure it is down so that it will produce ice. ice tray took a few hours to fill with water initially, must be on a timer or something.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from COLDSPRING, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice tray filled up with water. Stopped making ice.
As per instructions. Removed parts from old ice maker, and installed them on new one, Then installed it in the freezer. Works good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cami from Carmel, IN
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
evaporator coils were frozen solid and air wasn't flowing across them
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
Was this instruction helpful to you?
Thank you for voting!