Models > RB19HA-3A > Instructions

RB19HA-3A (8C67A) Magic Chef Refrigerator - Instructions

Jump to:

All Instructions for the RB19HA-3A
106 - 120 of 144
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
patrick from livonia, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dale from Sterling, AK
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
wouldn't make ice, door seal was hot to touch, warm in fridge.
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Honz from Tucson, AZ
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Socket set
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Ceres, CA
Parts Used:
W10156818
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
broken fan blade
unplug refrigerator, take backing off with nut driver. Pull old blade off and put new blade on. Put backing back on and plug in.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Strafford, NH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Socket set
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Batavia, OH
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from Granite City, IL
Parts Used:
833697
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Wrench set
Not cooling properly/ door divider getting hot.
The video of the repair is a helpful guide, but my refrigerator has the compressor very close to the condenser fan motor. With the compressor comes the copper tubing that is all in the way. I had to carefully bend them now and then to allow me to get my hands in position. The how to is easy, but the working with tools in cramped quarters was difficult. I think my Maytag side by side model makes for this job to be difficult, maybe yours may not be so bad. I took a couple of hours to complete. After the first hour, I covered the bare wires, and plugged the frig back in so it could do some cooling. I placed a small in front on the condenser to blow across it. Had a little break, then finished the job.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Sacramento, CA
Parts Used:
WP61004888
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Temp in the refrig side was too high. Freezer OK
I unpluged the refrig, removed the shelves and the back panel on the freezer side of the unit. This exposed the fan motor and fan blade. I removed two screws holding the fan unit in place, unpluged the wires connecting the fan unit to power, and then removed two other screws securing the fan motor to the bracket. I removed the fan motor blade from the old unit and installed it on the new fam motor. I replaced the fan unit into the bracket, pluged the wires back into the fan motor and secured the motor to the refrig. Replaced the back panel and shelves, pluged the refrig into the wall.....easy.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Pinckney, MI
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer was not Defrosting
I have an Amana freeze and I followed the procedure in the video. Which is very good! However on the Amana Model there two slight differences in the procedure that I felt I needed to do. The first one is, the condenser fan bracket is attached to the Freezer chassis with 4 screws, not three. The removal and installation of the back screw by the fan is a bear. I removed the other three and it allowed me to rotate the fan slightly to get more access to the fourth and did same on installation by just starting the 4th screw and then tightening it later. The second issue was my new fan hit the housing when I spun the fan. When I looked at the old one. It had a phenolic washer, between the fan and motor which spaces the fan out about a washer thickness from the motor. When I tried to remove the old one it broke in four pieces due to age. So, I made my own with a washer that I super glued to the motor housing after carefully centering it on and clearing the motor shaft . Seemed to work with out any more noise or balance issues...Thanks, your delivery was blindly fast and video was great!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dik from Quincy, MA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Fan was making noise, Freezer temperature was erratic
First, watched video on Part Select Website. Very good. Pulled Appliance out from wall, Pulled the power plug, and removed the back shield covering the working parts of the unit. Found the fan and it was almost the same setup as on the video except that I could not get to one of the screws holding the motor in place so had to remove the entire bracket with the fan. Not too hard. Cleaned away dust and gunk around the site and noticed that the fan pulled air through a tunnel-like condenser coil that was packed with gunky lint...this is what probably killed the motor. I cleaned out the tunnel with the bottle brushes and vacuum and installed the new motor / bracket assembly. Then replaced the shielding around the fan and the back cover .panel. This is important because these form the channel that guides air flow throughout the condenser coils. This particular refrigerator has a barrier underneath which guides air flow from the front left to the condenser, through the fan, over the evaporator drip pan and out the right front. I cleaned all the lint and gunk from this area as well. I also made an air filter (cut from a furnace filter) and wedged it in front of the air entry section. This should keep the condenser coil cleaner over time but you have to remember to change the filter once a year. Probably should clean the condenser coil every 5 years as well. This unit has been very reliable over 20 years and may well go for another 20. Good luck with your repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dora from Rock Island, IL
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light would come on and off
Viewed the viedo - it showed what to do
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Sykesville, MD
Parts Used:
WP60106-35
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set, Wrench set
Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Greenville, OH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Condenser motor stopped working
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from New Albany, IN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nancy from Gallatin, TN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
condenser fan wore out
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RB19HA-3A
106 - 120 of 144