- Customer:
- John from Land-o-Lakes, FL
- Parts Used:
- 4930JJ2028F
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
door latch cam brocken
After reviewing the parts picture of the left door I was able to disasemble the door gasket to replace the gasket holder which also mounts the brocken cam. No specail tools needed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JAMES from SCOTIA, NY
- Parts Used:
- 4930JJ2028B
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Lh Door Cam Holder Broke
Caution removing plastic molding with putty knife or flat bar . Roll the gasket toward the inside of frig ,push old holder up carefully out of gasket. Half way out tilt holder back to avoid ceiling . Save old holder for template ,remove screw from bottom,push out rod ,caution clip is spring loaded, install in new holder in reverse,slide back into gasket(carefully)!!replace molding