Carl from WILMINGTON, NC
Parts Used:
W10873791
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice Maker Quit Making Ice
In reading other post for this problem on the Parts Select web site, I checked the solenoids on the Inlet Valve (PN WPW10341320) located behind the refrigerator. A previous post indicated the solenoid should read between 500 and 1500 ohms. In checking, I read around 290 ohms, and confirmed the solenoid was ok. There were other items to check, including the primary water inlet valve and filter. I confirmed water these were ok as the water dispenser on the unit worked properly, and the filter has been replaced on a regular basis. I Ordered a new Ice Maker (PN PS11738120) and replaced as directed in previous post. After several days, the new ice maker did not work. I removed the solenoid connector for the water dispenser which is located next to the ice maker solenoid on the inlet valve, and connected to the ice maker solenoid. I depressed the water flow switch located on the door and the solenoid opened, and dispensed water into the ice tray. I confirmed the solenoid was not the issue. I also was concerned about the ice maker over flow lever that is connected to the ice maker. this switch shuts off the ice maker if the ice level is too high. I checked the old ice maker and determined a blue and yellow wire were connected to the switch, and terminated in the buss connector that connects the ice maker and the refrigerator. in normal condition, the switch should be closed. when I checked the replacement ice maker, I found the switch was open, which kept power from turning on the water supply to the ice maker. Parts Select sent a replacement, and after installation, the unit worked properly.
Issue solved.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Roanoke, VA
Parts Used:
4387478
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dave from Manchester Center, VT
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from DELTONA, FL
Parts Used:
WPW10225581
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
fridge stopped cooling then the freezer
Searched my issue on the internet then chose part select to see if bi-metal thermostat was available and it was so I ordered part which was under $30.00 incl. shipping. I then went to You Tube to watch how to replace the part but most importantly to find out where it was located and degree of difficulty. Replacement was rather simple and it fixed our 22 year old fridge. I must add that when I looked up the part it also told you what percent of the time that particular item actually fixed the problem based on others experience. I thought that was neat info. as I felt better about ordering something that may or may not fix my problem. Thank you,
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hans from OGDEN, UT
Parts Used:
WPW10475495
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Raise side of fridge and slide 2x4 under side with broken wheel.
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from GOWANDA, NY
Parts Used:
W11087200
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
POWER SURGE TOOK OUT THE POWER INVERTER
ONCE WE KNEW THE COMPRESSOR WAS NO LONGER FUNCTIONING , USED A MULTI METER TO VERIFY 120 VOLTAGE TO THE INVERTER WAS PRESENT, FOUND 120 VOLTAGE TO THE INVERTER WITH NO VOLTAGE TO THE COMPRESSOR. OHMS OUT THE COMPRESSOR, FOUND IT WAS WITH IN SPECS. REPLACED THE INVERTER AND ALL IS WELL ONCE AGAIN.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne from Arlington, TX
Parts Used:
4387478
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Elyse from Skokie, IL
Parts Used:
4387478
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from WEST PALM BCH, FL
Parts Used:
W10873791
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Icemaker not making ice
Simple to replace. 6 screws out. Unplug connections... Plug back in, replace screws.

Unfortunately still not making ice. Will try fill valve replacement.
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from STATEN ISLAND, NY
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Freezer work perfectly, Refrigerator Stopped getting cold, water line froze, there was ice Forming around the condenser in the bottom of the refrigerator behind the drawers
Freezer worked great, refrigerator stopped getting cold and lots of ice formed around the condenser on the bottom of the refrigerator.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ray from KILL DEVIL HL, NC
Parts Used:
W10873791
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice maker quit making ice
1 turned off the unit
2 removed the cover panel be removing 4 Phillips head screws
3 unplugged the on off switch attached to the cover panel
4 removed the two 1/4 in nut head screws holding the ice maker
5 removed the ice maker and disconnected the power at the join
6 performed the above steps in reverse
7 the unit has since been producing ice
Repair appears to be a success
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Dublin, NH
Parts Used:
W10311524
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
air filter needed replacement
pulled the top shelf and poped open the door and replaced the filter
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from ENDWELL, NY
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when you try and remove the cable assembly. Hope this is helpful.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?