KTRS20KXWH10 KitchenAid Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from Cedarville, OH
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers, Socket set
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- bill from escondido, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Hummelstown, PA
- Parts Used:
- 1129316
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Was not making ice and the filler tray was chipping material.
With a socket set and screw driver I removed the old ic e maker . It took about 1 hr. I worked slowly as not to make a mistake. The only part that gave me a problem was the plug. You need to take off the face cover to press down on the plastic release clip. Putting it back took half the time because you knew what to look for.Just plug it in and mount the screws back in place , make sure it was level and I had ice in about an hour.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Arnold, ME
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
I had frost build-up in the freezer.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Hudson, FL
- Parts Used:
- W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Refrigerator quit refrigerating
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lawrence from New Bern, NC
- Parts Used:
- WP4387503
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer compartment iced over, food thawing,
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from miami, FL
- Parts Used:
- WP4387503
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
water was leaking down from freezer section to bottom part of unit
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me access to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Pottstown, PA
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Noise coming from defrost timer
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michelle from Richardson, TX
- Parts Used:
- 72017
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Scratches in Surface
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
Was this instruction helpful to you?
Thank you for voting!
My refrigerator ran constantly and never got cold!
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever and I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Maxine from Birmingham, AL
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
would not cycle
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Benjamin from Daytona Beach, FL
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Brigham City, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- martin l. from JACKSONVILLE,, IL
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- peter from saint augustine, FL
- Parts Used:
- W11581579
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
part of a freezer support bracket was missing
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Was this instruction helpful to you?
Thank you for voting!