- JEFF from HAMPTON, GA
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Somers Point, NJ
- Parts Used:
- WR23X10725
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
10 minutes total.
10 minutes total.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from bensalem, PA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Garland, TX
- Parts Used:
- WR51X442
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Refrigerator & freezer became warm.
Unplugged the refrigerator. I took all the food items out of the freezer, took out the ice bin and shelves. Then I unscrewed the back panel and removed it. The freezer coils were frozen over with ice. Then I used a large fan to thaw the ice and cleaned up the water with towels.
I unscrewed the old defrost heater at the bottom of the coil section, removed it and screwed the new defrost heater part in. I ended up using some dikes to cut the wiring midway up . ( I was going to use the new plastic plug that came with the new part, but it wasn't correct ). I spliced the wires together ( the color scheme was the same - pink to pink, blue to blue, etc), capped them , taped them with electrical tape, and I covered them with a corner from a sandwich bag and taped them a bit more to keep moisture out. Then I tucked the wiring up away from the coil section. I also spliced this little cylindrical part into the existing wiring harness and clipped it onto the copper tubing. ( I suspect this is the defrost timer, but I'm not sure ). After I removed the the old cylindrical little part, I noticed the cap was popped out of it. (it looked like it was damaged a bit ). Once I got all wiring tucked away and back in place, I put the back panel back on, plugged it back in. Voila'. Easy as pie. It's been running fine ( about a week now) ever since. I replaced the thermostat sensor first since that was the cheapest part, but it wasn't the problem. So I moved on to the defrost heater and that ended up being the bad part. I repaired my refrigerator for less than $100.00. Thanks PartSelect. You rock!
I unscrewed the old defrost heater at the bottom of the coil section, removed it and screwed the new defrost heater part in. I ended up using some dikes to cut the wiring midway up . ( I was going to use the new plastic plug that came with the new part, but it wasn't correct ). I spliced the wires together ( the color scheme was the same - pink to pink, blue to blue, etc), capped them , taped them with electrical tape, and I covered them with a corner from a sandwich bag and taped them a bit more to keep moisture out. Then I tucked the wiring up away from the coil section. I also spliced this little cylindrical part into the existing wiring harness and clipped it onto the copper tubing. ( I suspect this is the defrost timer, but I'm not sure ). After I removed the the old cylindrical little part, I noticed the cap was popped out of it. (it looked like it was damaged a bit ). Once I got all wiring tucked away and back in place, I put the back panel back on, plugged it back in. Voila'. Easy as pie. It's been running fine ( about a week now) ever since. I replaced the thermostat sensor first since that was the cheapest part, but it wasn't the problem. So I moved on to the defrost heater and that ended up being the bad part. I repaired my refrigerator for less than $100.00. Thanks PartSelect. You rock!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GEORGE from ELIOT, ME
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Will not make ice
Bing , Bang, Boom.
Was this instruction helpful to you?
Thank you for voting!
The two parts I replaced had rusted. Left rust chips in ice.
I carefully removed the screws and laid aside in order. Taking off the ice grinders was the trickiest part, but I had read before to make sure to keep them in order. Replaced two new parts and reassembled. Pretty simple, but just keep track of where each part goes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from The Woodlands, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Lafayette, CA
- Parts Used:
- WR17X4310
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The original ice auger jammed and destroyed the original icemaker
The replacement part was an exact fit and slipped right into the space where the old one was. No tools needed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Divide, CO
- Parts Used:
- WR60X187
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
John Moragues
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from frankston, TX
- Parts Used:
- WR17X4310
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
rusty auger and crusher broke
as simple as taking off 4 screws from door of old one and putting door on new one and putting bucket back in place
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from Columbiana, AL
- Parts Used:
- WR9X489
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Louisville, KY
- Parts Used:
- WR17X3484
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Plastic light sheild over freezer light had broken.
Removed old sheild and reached in freezer replacing sheild with screwdriver. 3 - 4 minutes.
Ordered sheild online one afternoon and received the nest afternoon. Great transaction. will use again when needed.
George in Louisville, KY
Ordered sheild online one afternoon and received the nest afternoon. Great transaction. will use again when needed.
George in Louisville, KY
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Lakeland, FL
- Parts Used:
- WR51X442
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The regrigerator would not defrost properly. After doing some online research, I determined that the Defrost Heater was no longer working.
First, I had to remove the back panel in the freezer. This exposes the cooling coils and the Defrost Heater which is located toward the bottom underneath the cooling coils. There are four screws that have to be removed before the old Defrost Heater can be taken out. There are two wires that go from the Defrost Heater to the power connection. These wires are blue and pink. I had to remove some pieces in the back at the top of the freezer to expose the power connection for the Defrost Heater. These pieces were held in place with phillips screws, so they easily came out to reveal the power connection. The power connection is a simple plug-in type. The Defrost Thermostat is also included with the new Defrost Heater. This is a round piece which is clamped onto the Cooling Coils. I removed the old Defrost Thermostat. It is connected to the same power connection with the Defrost Heater. After I mounted the new Defrost Heater and Defrost Thermostat and connected the power, the refrigerator has worked perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hop from Houston, TX
- Parts Used:
- WR9X489
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- donald from opelousas, LA
- Parts Used:
- WR60X187
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Was this instruction helpful to you?
Thank you for voting!