1069304783 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Bob from Middlefield, CT
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
wasn't making ice. The ice bin actually filled up with water.
Removed old valve first, found part # on it.
Entered part # into search box on computer.
It came up with the right replacement part the first time!!!
Ordered part, it came in sooner than I thought it would.
I attached the supply line, pushed in the plastic outlet hose, connected the power line, and attached it to the refrigerator frame. We had a full container of ice the next morning.It couldn't of had been easier.
Entered part # into search box on computer.
It came up with the right replacement part the first time!!!
Ordered part, it came in sooner than I thought it would.
I attached the supply line, pushed in the plastic outlet hose, connected the power line, and attached it to the refrigerator frame. We had a full container of ice the next morning.It couldn't of had been easier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Roanoke, VA
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- WILLIAM from Altamonte Springs, FL
- Parts Used:
- 4318047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Ice Maker Quit Making Ice
Ice make was still working but no water coming in to make ice . Pulled refrigerator back and found water valve at bottom of refrig close to the floor. I disconnected water line and electric plug - went to whirlpool web site - no help at all to confusing - found partselect and compaired picture of old valve with picture of new valve . When I got it in mail it took 30 min to install - working fine now hint - mark top of electric plug so you install correctly
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dana from Canyon Lake, TX
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Redmond, WA
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer was dripping water into refrigerator below
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Needed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STEPHEN from FENTON, MO
- Parts Used:
- WPW10225581, W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer No Longer Cools
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Locust Grove, VA
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Making a god awful racket.
Ok its the garage "adult " Beverage chiller.
Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from San Diego, CA
- Parts Used:
- 4317943
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker was leaking
This is an incredibly easy repair.
1) Remove the three screws holding the old icemaker
2) Disconnect the electrical connection (I used a spoon to get in and undo the connector clip
Do the opposite to install the new icemaker.
Total elapsed time was about 5 minutes.
1) Remove the three screws holding the old icemaker
2) Disconnect the electrical connection (I used a spoon to get in and undo the connector clip
Do the opposite to install the new icemaker.
Total elapsed time was about 5 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Annapolis, MD
- Parts Used:
- W10190935
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
The icemaker in my freezer stopped producing ice
1. Removed the icemaker door
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anne from Arlington, TX
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
My U-line ice maker quit filling.
I used this part on a little, under-counter U-line ice maker that is the best little ice maker in the world. The single solenoid part from U-line cost more than twice as much as the generic GE one I ordered from you. It arrived in only 2 days and I was able to just remove the inlet and outlet line from the old solenoid and unscrew the bracket to remove it. I used the included bracket and one screw affix the new one to the ice maker, then just pushed on the inlet and outlet lines, tightened them on, plugged it back in and In about 20 minutes from start to finish, it was back in business, cranking out ice really quick as it was before. Could not imagine summertime in Texas without my U-line,,,Thank you!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Orangeburg, SC
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
3 inches of frost in Fridge, 72 degrees in Fridgerator
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dave from Manchester Center, VT
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
reassembled the pieces.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dale from Blaine, MN
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer making loud whining noise-Fridge not cooling well
Removed the 3 screws in the back of the freezer, pulled back the metal back plate on the freezer. Removed 4 nuts on the plastic housing that holds the fan and pulled the housing down. Disconnected the wires, unscrewed the 2 screws holding the fan to the housing. Replaced old fan motor with new fan motor onto housing just as it was before. Reconnected the wires. And tested the motor. Worked great. Re-assembled everything as it was and it was done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randy from LAFAYETTE, LA
- Parts Used:
- W10190935
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Bad module on icemaker
First shut off water supply and unplug power. Unscrew icemaker assembly from side wall with 3 screws. Remove front cap and you can clearly see module. Unscrew and remove module ( only three screws). Install new module and revers procedure to finish up. Ice was ready in just a few hours. Video provided by this site was right on and left no questions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from DELTONA, FL
- Parts Used:
- WPW10225581
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
fridge stopped cooling then the freezer
Searched my issue on the internet then chose part select to see if bi-metal thermostat was available and it was so I ordered part which was under $30.00 incl. shipping. I then went to You Tube to watch how to replace the part but most importantly to find out where it was located and degree of difficulty. Replacement was rather simple and it fixed our 22 year old fridge. I must add that when I looked up the part it also told you what percent of the time that particular item actually fixed the problem based on others experience. I thought that was neat info. as I felt better about ordering something that may or may not fix my problem. Thank you,
Was this instruction helpful to you?
Thank you for voting!