Models > 36370947000 > Instructions

36370947000 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 36370947000
16 - 30 of 340
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Erick from Elmhurst, NY
Parts Used:
WR2X9391, WR23X10725
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Light switch inside refrigerator wasn't working
First turned off power and removed top shelf.
Then I used a flathead to slowly pry the switch out by the two sides. You just anlge ita bit and it slideds out easily. Then I disconnected the wires from the old switch, connected the new one and installed the new switch by snapping it back into the cutout.
31 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GARY from PARRISH, FL
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
34 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bob from San Diego, CA
Parts Used:
WR9X559
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Socket set
Refrigerator would not cool but freezer worked
Based on the symptoms I assumed the thermostat was faulty and replaced it. However, that did not correct the problem so I use a hairdryer to try to clear the vent to the freezer and dusted the coils underneath the unit. Still no luck. Next I pulled the back panel off of the freezer are to check the fan but it was working just fine. However, the coils by the freezer fan were packed heavily with ice so I thawed the ice. That worked.
33 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Greenfield, IN
Parts Used:
WR50X10010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer coil frozen solid
Removed the back cover of freezer to acess the coil. Turned the timer to defrost and checked the voltage across the heater. Didn't have any. Stayed on the common side of heater and measured on both sides of thermostat and one side didn't have any voltage. Shorted the thermostat wires together and heater started working.
28 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne from Renton, WA
Parts Used:
WR57X10033, WR2X8474
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
water running down inside to lower compartment
Removed items from freezer, removed 2 nuts from ice maker and set ice maker aside. Pulled old fill tube from back (no tools). replaced with new fill tube. Removed old valve at back of ref. installed new valve kit and reconnected plastic line. placed clamps on plastic line to insure no leaks. No more leaking and ice maker works great. No ice cubes freezing together.
21 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Glendale, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from Concord Twp., OH
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set, Wrench (Adjustable)
water valve didn't shut off completly
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Mebane, NC
Parts Used:
WR29X5171
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Ice maker would not make ice..
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jania from Novato, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Ocean View, NJ
Parts Used:
WR24X450, WR24X449
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Both the freezer and refridgerator seals were leaking
We took the old seals off, T\they really just peal off, and replaced with the new ones.We were not really sure how they went on, because there really was no instructions with the seals, but we figured it out. After we really figured it out and got started, it was pretty easy. The only instructions that come with it is how to prep the seals before they go on.
18 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Yuba City, CA
Parts Used:
WR29X160
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Kingwood, TX
Parts Used:
WR60X30349
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Motor rattled loudly
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Simi Valley, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Bellevue, WA
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Ice maker did not work
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Bradenton, FL
Parts Used:
WR30X10154
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Ice bucket missing
I discovered the ice bucket missing from my rental unit at the beach. I was able to go online with my Blackberry, easily navigate your website using the model number to look up the part information , order it, and have it in place for the next renter.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 36370947000