59662912200 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Shelley from Katy, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from Tyler, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Icemaker leaked water into ice bin causing a glob of ice
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installing the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bob from Hesston, KS
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set, Wrench set
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Pasadena, CA
- Parts Used:
- 12001937
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Auto defrost not working
Found the coils in the freezer frosted up and no cold air getting to the refrig compartment. I first replaced the defrost timer but should have checked with a volt meter as it turned out that it was a thermostat on the coils in the freezer that was faulty, it actually had a visable defect, it was bulged out. I think that this thermostat prevents the defrost heater from over heating the coils. Replaced the defrost timer an this thermostat and all is good now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Darrell from Pepperell, MA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice Maker broke at the begining of summer !!!!!!
The new Ice Maker Assembly arived in less than 24 hours. I was amazed that it came so fast.
I had already removed the old ice maker in order to get the modle number.
I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator in less than 10 minutes. With in a few hours I had ice again !!!!!
I would definatly use partselect.com again.
I had already removed the old ice maker in order to get the modle number.
I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator in less than 10 minutes. With in a few hours I had ice again !!!!!
I would definatly use partselect.com again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Lincoln, NE
- Parts Used:
- WP67001036
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
ice buildup in freezer
The part was an exact match to the old one and the instructions from your website were all I needed to complete this repair. My wife thinks I am somewhat of an appliance genius now. Could not have done it without you...thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Minneapolis, MN
- Parts Used:
- WP12555902
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The refrigerator quit cooling and the compressor would click on and off
I took off the faceplate on the back to access the compressor and took off the overload relay switch from the compressor. The overload fit on the compressor correctly. The top quick connect did not fit on the overload so I had to cut the quick connect off and replace the wires with correct size clamps and replace. It has been working fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ty from Wentzville, MO
- Parts Used:
- WPW10128551
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator wouldn't get cold enough.
Freezer would get cold at bottom and some of the refrigerator. Took of freezer back panel and located freezer fan. Took a meter and saw power was getting to it, but not working. Removed fan and replaced with new on, working like a charm. Cold air was not circulating enough throughout the unit because fan was not working. It was not the thermostat or adapter control.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jesse from hacienda heights, CA
- Parts Used:
- W10823511
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- SHIRISH from WHEELING, IL
- Parts Used:
- WP65889-4, WP12555902
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
Compressor was not working
Open back cover and check thecomprosser and ffan. Fan was working and compresore was very hot and freon pipes are not cold. Check the connectivity with the resistor meter on compressor and all 3 pin were checked out ok. that means compressor is ok. Then check overload relay and there was a short butn out. take the part # and order from partselect and i got in 3 days costiing me less than $ 20.00. replaced relay and frezzecompressor start colling the syatem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Georgette from Webster, MA
- Parts Used:
- WPW10671238
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
center rail to hold drawers straight was broken
Took drawers out, inserted the rail and put the drawers back in and voila. Fixed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Marietta, GA
- Parts Used:
- 12001937
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer too cold with frost along the back wall and fridge warm.
Removed the ice maker. Removed the screws holding the back panel in place. Unplugged the fridge, cut the wires for the defrost thermostat and installed the new thermostat with the connectors provided. For anyone with a similar problem, I would recommend getting a multi-tester and testing the Defrost timer, defrost thermostat, and defrost heater all the same time according to the directions on this site. Then order the parts that are bad and be up and running in no time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from New Braunfels, TX
- Parts Used:
- WP2182124
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice stripper broken on ice maker
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ken from brick, NJ
- Parts Used:
- WPW10443311
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice and Ice crystals forming in freezer
Noticed freezer door gasket was dried out unscrewed the door panel off pulled old gasket out and reinstalled a very easy job works like new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Rhinelander, WI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Old Icemaker noisy and stopped making Ice
The old icemaker had a bad motor and would stall in the fill cycle causing my kitchen to flood on occasion.
The new one was so quiet, I thought it didn't work!
Anyway, one nutdriver and 5 minutes and I had the new one in there... It is so quiet, and I always have plenty of ice now!!!
Thanks!!!
The new one was so quiet, I thought it didn't work!
Anyway, one nutdriver and 5 minutes and I had the new one in there... It is so quiet, and I always have plenty of ice now!!!
Thanks!!!
Was this instruction helpful to you?
Thank you for voting!