106S13GIM Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from Manlius, NY
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
not makinig ice due to lack of water flow to maker
Followedinstructions that came with kit. Kit parts were unnecessary as new valve fit in exactly as old one had been. Quick connect for flow out of valve to maker was a surprise as no threaded connection present and no nut necessary; simiply push the line into place. Reconnect water line, check for leaks and refasten back covering. Instructions with kit contained an incorrect drawing of connecting water outflowline; a one page addition verbally gave correct info, but detailed step by step instruction for this one connection was confusing. Otherwise, could not have been easier; surely a do-it-yourself project.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Hobe Sound, FL
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
See below
The defrost timer that I ordered form you did the trick. My fridge was
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defective. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defective. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jolinda from Eau Claire, WI
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Freezer was too cold and refrigerator was too warm
After receiving the part, I watched the installation video on the PartSelect website. The step by step demonstration was excellent. I felt confident I could do it myself after watching the video just once, and utilizing the written instructions that came with the part. The installation went smoothly, and my refrigerator is functioning correctly again. Best of all, I did not have to go through the hassle and expense of hiring a repair person!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from thibodaux, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Honz from Tucson, AZ
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Socket set
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Paducah, KY
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
The freezer compartment was not cold enough.
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from LAS CRUCES, NM
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Virginia Beach, VA
- Parts Used:
- W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
How to get timer out of defrost cycle?
Talked to local appliance repair tech, who explained how to manually turn timer with a screw driver and listen to the switch go from on to off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOHN from TWINSBURG, OH
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Water Was Not Reaching The I Ce Maker
Disconnect ac power line, disconnect power line going to the water valve. Turn water off atthe cockvalve. Disconnect water line to valve. Disconnect plastic tubing going in the valve. If plastic is old you may have to replace it to keep from leaking at the quick connect coupling. Connect water line and plastic tubling to new valve, connect power clips to new valve. Plug in the refrigertor and turn on water at the cock valve and your good to go
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- patrick from livonia, MI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from New Albany, IN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Salem, WI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bryan from Midland, NC
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrigerator not cooling
Exactly how the part select video described it. Threw a little curve ball figuring out which timer setting to set it to. But the instructions provided with defrost timer walked me right through it. No problem. After installing part nothing happened for about ten minutes, which had me second guessing each and every step. Then, like magic, cold air began blowing. What a relief. Thanks so much, love this site. Refrigerator works like new!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denise from Manchester, NH
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Ice Maker was overflowing into ice bin when filling
Thought we'd try the Water Valve before replacing the ice maker. Ordered new valve online on Saturday, it arrived on Tuesday. I installed it twice in less than 30 mins. Had a little leak the 1st time, so I uninstalled it, trimmed up the water line with a box cutter and reinstalled without issue. No leak this time. Easy Peasy. My husband said "You're good, you." :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marcia from Kansas, OK
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Both the freezer and bottom of refrig too hot
Was very simple once I found out where the defrost timer was located. I had a friend walking me through trying to find the location on the phone. Not all models have them in the same place. Once the part was located all I had to do was remove the cover, unplug the old one and plug the new one in just the way the old one came off. The black wire was easy to locate on the old and just matched it up. Put the cover back on and plugged it in. It was no time till I started feeling it cool. Checked both top and bottom with thermomater and it was where it should be within 12 hours. I am happy and using it again. Was almost ready to throw it out. Did not know it was so cheap to fix one. Nothing anyone can't handle. If this woman can do it anyone can.
Was this instruction helpful to you?
Thank you for voting!