Icecube dispencer stopped working because of lack of water seal on motor shaft.
I removed the ice bucket and motor cover on the inside of the left door. Then I removed the 4 screws that hold the motor in place and unplugged the electrical connector. The old motor shaft was all rusted and housing was cracked letting water inside the motor. That's why it failed. The new motor I ordered from Part select came with a rubber seal that I slipped on to the motor shaft. That will stop any water from entering the new dispencer motor. I reinstalled motor and the dispencer works great. Total time for removal and replace was 20 min. A novice can do it. Bill WI.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyle from INDIANAPOLIS, IN
- Parts Used:
- W11452196
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Loud buzzing coming from freezer compartment and no ice was being made in the ice dispencer
Pull out freezer drawer and unscrew 2 bolts holding freezer door. Remove top tray retaining pins...remove top tray...then remove bottom tray...remove 4 screws in the back of the freezer...remove cover...unplug all wires connecting the fan...remove fan housing...swap parts from old motor to new motor...then reinstall fan and reconnect wires...replace back cover and then screws in the four bolts and reinstall the drawers and then the freezer door
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from East Meadow, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
light not working in fridge
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Antonio from San Antonio, TX
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from LONGMONT, CO
- Parts Used:
- W10311524
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Changed air filter
Very simple, easy, and quick! Anybody can do it!!
Was this instruction helpful to you?
Thank you for voting!
Water on the floor, fridge leak
Back cover was wet in the area of the inlet valve(sign). Water on the floor. 90% of the time is a leaking inlet valve. But it could be frozen water on the drain pan- so I exposed the radiator fins and drain pan and looked. No ice so I went to the valve and opened the copper line valve and waited a few minutes- as soon as water was called by the. Ice maker it leaked. So I went ahead and replaced the valve and after I made sure no leaks were visible I replaced the back cover and continued to observe and all was good. I treated the fridge as a new installation, changed filter and dumped the next two ice buckets. Then I proceeded to demand brownie points.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Duncan from Metairie, LA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Jacksonville, FL
- Parts Used:
- W10316760
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Lower Freezer worked fine, but upper refrigerator would not cool.
I first replaced the lower (freezer) evaporator thermistor based on recommendation from other feedback, however that did nothing to resolve the problem. I subsequently discovered a diagnostic document hidden under the upper right door hinge, which helped me narrow the problem down to the upper (refrigerator) evaporator fan motor. After replacing the fan motor, my refrigerator is up and running again. The only challenge was accessing and removing the access panel(s) and air column. Once those were removed, replacing the fan motor was simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Dublin, NH
- Parts Used:
- W10311524
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
air filter needed replacement
pulled the top shelf and poped open the door and replaced the filter
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dave from Manchester Center, VT
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
reassembled the pieces.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from WARMINSTER, PA
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sung-Su from BISMARCK, ND
- Parts Used:
- W11396033
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from WISC RAPIDS, WI
- Parts Used:
- W10822606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice Augur Motor not Working
Very easy doit repair. Watched Youtube video helpful. Small nut driver and flashlight the only tools needed. Ordered part with standard delivery and received the new motor in under 24 hours! Impressive. I will use Part Select again! So happy to have a working augur. No more stale ice at the bottom of the bin. No more scooping ice with fingers!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Luke from Jewett city, CT
- Parts Used:
- W11168758
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Small water leak from cracked fitting leading into water reservoir fill valve.
Remove some shelving and have a towel handy. Opened water filter door to expose two 1/4” screws. Removed 2 screws. Placed my hands firmly on upper panel and gently pulled/tugged panel forward and slightly down. Disconnected roof lighting clip. Removed panel from frig. Disconnected both ends from solenoid fill valves by pressing in the colored locking piece to release tubing while pulling tube out. Cut zip ties and removed old leaking reservoir. I also removed the straight reservoir seeing as the part I replace was redesigned and the other one was not needed. Put new zip ties in place. Slid the new part into position and pressed the ends into the solenoid valves. You do not need to press in colored locking pieces, they will self lock. Secured with zip ties. Grabbed a container and filled it up with water through the door to fill and purge and check for leaks. Reconnect light clip, reinstalled top liner and snapped into place. Put screws in. Closed filter door. Took about 15 minutes. I did watch a you tube video prior to attempting this repair myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Winston A from Brooklyn, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!