Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
GEORGE from ELIOT, ME
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Will not make ice
Bing , Bang, Boom.
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Divide, CO
Parts Used:
WR60X187
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Osvaldo from Miami, FL
Parts Used:
WR57X10051, WR17X2056
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench (Adjustable)
Very low flow from water dispenser, hollow ice cubes, broken ice dispenser helix
Unplugged refrigerator. Removed cardboard cover, vacuumed lint from coils and equipment area. Removed dual valves and labeled the four electrical leads with masking tape. Cut off the end of water lines to dispenser and ice maker to remove threaded connections (New are simply push on). The water leads are of different diameters, so there is no confusion.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
P. Michael from Tustin, CA
Parts Used:
WR9X502
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice in freezer running down sides
This is a built-in unit. Remove the external bezel at the top of the unit. Reach through the unit and unplug the frig. On the compressor unit, you'll see a vertical metal panel. Remove the metal panel and the timer is right behind it. Remove one wire at a time and switch it to the new timer. Remove timer and replace with new one.

Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Drew from Spring Lake, NJ
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Ice Maker wouldn't work, water tube freezing up, water leaking onto floor
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Partselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from New Braunfels, TX
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Door would not close properly
I stacked three 2x4's that were approximately as wide as the door in length. This required lifting the door about 1/4" but it also got the weight of the door off the cam so the bracket assembly that the cam was attached to could be removed. I drilled out the rivet that held the old cam in place and like previous DIY's had to use a small bolt and nut to secure the new cam in place. Reattached the bracket with the new cam and that was it. The only problem was that the head of the bolt I used was not flat enough to allow proper clearance for the door to swing freely without feeling some drag and the wife noticed that immediately. I told her to wait until the weekend and I would again remove the door and file down the head of the bolt to allow the required clearance. After a few days of use, the door itself ground enough material off the head of the bolt so that the door began to open and close properly. So now she's happy, I'm happy and the dog is happy.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Hubbardston, MA
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set, Wrench (Adjustable)
Door Closing Cam Disintegrated
The door closing cam on the refrigerator door was a snap to replace. However, I'm still baffled on how to replace the freezer door side. The condensation tube from the door runs through the door pivot and joins to a compression fitting behind the bottom trim piece. The compression ring is behind a formed lip on the tube and won't slide off. I could cut the tube but I really didn't want to do that. If anyone has done this and knows the trick to replace it, I would appreciate it.

Ed. Please post your question at our repair forums, forums.partselect.com.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from Rose Hill, KS
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.

The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Todd from Saint Paul, MN
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
D.H. from Mulberry, AL
Parts Used:
WR29X5153
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken gear
Removed old gear and tapped the replacement on.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Lake Sherwood, MO
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Door Would Not Close Properoy
Door cam disintegrated after 20 years. This was a terrific site for suggested repairs. My problem was not paying attention to how the door shim, cam and spacer were placed on the hinge. Most of the site's instructions did not forewarn the obvious...pay attention when doing repairs!!

Instructions from others were generally pretty good but as adept as I am at D-I-Y I still did not pay attention to how I took something apart so it could be assembled properly.

I don't think that ordering an entire door hinge set is necessary. It does not appear that shims and/or spacer come with the hinge assembly. Door cam was all that was needed. I thought about replacing the cam on the freezer side but won't do it until absolutely necessary.

This is a very good website and my thanks to all of the posts for the instructions!!
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
donald from opelousas, LA
Parts Used:
WR60X187
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
H.K. from Seagoville, TX
Parts Used:
WR55X24065
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
compressor not starting
Refrigerator is not cooling. Light and fan working. Changed the capacitor.. Still not cooling. Back to discovery mode.It may be the timer
Certainly not PartSelect's fault. They have great service.
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ben from Warrior, AL
Parts Used:
WR9X502
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Refridgerator wouldn't cycle into defrost mode without doing it manually.
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Lafayette, NY
Parts Used:
WR13X10020
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Cams on Hinge assembly broken, door didn't close properly
I supported door with 2* 6 scrap wood. I used cedar shingles to raise door to correct height.
Using a socket wrench, I removed the hinge from the fridge and the cam assembly from the door.
I installed the new hinge and cam using the shims thatwere behind the original parts.
I removed the 2*6 supports and the door now works perfectly.
7 of 9 people found this instruction helpful.