Eartis from Mckenzie, AL
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refregirator would not freeze properly. It would stay in the defrost mode at times.
I did the repair just as your video showed me. It worked out great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Strafford, NH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Socket set
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Myrna from Decatur, IL
Parts Used:
833697
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Fan motor worn out
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's working fine now and I'm a satisfied customer!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from Apollo, PA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Refrigerator not shutting off, liquids freezing in fridge
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years old we opted to just get a new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Metuchen, NJ
Parts Used:
4318047
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
New Part Was Different From Previous Part
First attempt was difficult. Part was different and instructions applied to previous part that did not have quick connect. Not clear where quick connect was to be used. Result no ice!second attempt used quick connect in reverse connections and now have plenty of ice. Combination of change in part appearence from previous one ,and different from instructions included with new part, resulted in confusion in installation. In the long run, it worked out well.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BOB from LAKE HAVASU CITY, AZ
Parts Used:
4318047
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Soleniod Valve Failed
The refrig. Is about 30 years old. The new solenoid looked and mounted nothing like the original. I driled holes in the frig and attach the solenoid with sheet metel screws. There were not enough fittings and hoses so I bought a braded metal hose to attach the ro line and the valve inlet. I used the parts in the kit to attach the water feed line. To the ice maker I did not try to stuff all the hoses and lines back into the cramped cavity in the frig. W ell how does it look? The solenoid sticks out a little and there are a lot of hoses behind the frig. I do not spend much time behind the frig so who cares. The ice maker is making ice!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dale from Sterling, AK
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
wouldn't make ice, door seal was hot to touch, warm in fridge.
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Batavia, OH
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dik from Quincy, MA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Fan was making noise, Freezer temperature was erratic
First, watched video on Part Select Website. Very good. Pulled Appliance out from wall, Pulled the power plug, and removed the back shield covering the working parts of the unit. Found the fan and it was almost the same setup as on the video except that I could not get to one of the screws holding the motor in place so had to remove the entire bracket with the fan. Not too hard. Cleaned away dust and gunk around the site and noticed that the fan pulled air through a tunnel-like condenser coil that was packed with gunky lint...this is what probably killed the motor. I cleaned out the tunnel with the bottle brushes and vacuum and installed the new motor / bracket assembly. Then replaced the shielding around the fan and the back cover .panel. This is important because these form the channel that guides air flow throughout the condenser coils. This particular refrigerator has a barrier underneath which guides air flow from the front left to the condenser, through the fan, over the evaporator drip pan and out the right front. I cleaned all the lint and gunk from this area as well. I also made an air filter (cut from a furnace filter) and wedged it in front of the air entry section. This should keep the condenser coil cleaner over time but you have to remember to change the filter once a year. Probably should clean the condenser coil every 5 years as well. This unit has been very reliable over 20 years and may well go for another 20. Good luck with your repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
patrick from livonia, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Salem, WI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marcia from Kansas, OK
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Both the freezer and bottom of refrig too hot
Was very simple once I found out where the defrost timer was located. I had a friend walking me through trying to find the location on the phone. Not all models have them in the same place. Once the part was located all I had to do was remove the cover, unplug the old one and plug the new one in just the way the old one came off. The black wire was easy to locate on the old and just matched it up. Put the cover back on and plugged it in. It was no time till I started feeling it cool. Checked both top and bottom with thermomater and it was where it should be within 12 hours. I am happy and using it again. Was almost ready to throw it out. Did not know it was so cheap to fix one. Nothing anyone can't handle. If this woman can do it anyone can.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lee from Brooklyn, NY
Parts Used:
4387478
Difficulty Level:
Very Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
Protective cover for bulb had melted
I tried to just replace the cover rather than the whole unit but it was impossible - the cover would not go/stay on. I tried to remove the old unit completely but it would not unplug it was practically fused to the back of the fridge and the liner was cracking. I ended up breaking the cover and jerry rigging it over the bulb to prevent items in the fridge from being able to touch. Bad solution.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Virginia Beach, VA
Parts Used:
W10822278
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Socket set
How to get timer out of defrost cycle?
Talked to local appliance repair tech, who explained how to manually turn timer with a screw driver and listen to the switch go from on to off.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Paducah, KY
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The freezer compartment was not cold enough.
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 106W16EIM5